01SN0145-JAN24k.pdfJanuary 24, 2001 BS
STAFF'S
REQUEST ANALYSIS
AND
RECOMMENDATION
01SN0145
REOUEST:
Chesterfield County Board of Supervisors
Midlothian Magisterial District
North line of Midlothian Turnpike
Amendment of Conditional Use Planned Development (Case 89SN0242) relative
to height for a water storage tank and to permit communications antennae on the
water storage tank and height exception for such antennae in an Agricultural (A)
District.
PROPOSED LAND USE:
A water storage tank is planned. This tank will replace an existing water storage
tank on the subject property. In addition, this request would allow the installation
of communications antennae on the water tank. The total height of these structures
would be limited to 180 feet provided however, that any antennae mounted on the
top of the tank could not exceed ten (10) feet.
PLANNING COMMISSION RECOMMENDATION
RECOMMEND APPROVAL SUBJECT TO THE CONDITIONS ON PAGES 2 THROUGH 4.
Providing a FIRST CHOICE Community Through Excellence in Public Service.
STAFF RECOMMENDATION
Recommend approval for the following reasons:
The proposed water storage tank will meet the increasing water demand pressure
and fire flow needs in the Midlothian area.
The ~ suggests that communication towers should be located
to minimize the impact on existing or planned areas of development and that
communications facilities should co-locate whenever feasible. The proposed co-
location of communications antennae on the water storage tank conforms to this
criteria. Incorporating the communications facilities into the proposed water
storage tank will eliminate the need for an additional freestanding comrnunications
tower in the area, thereby minimizing tower proliferation.
The recommended conditions will further minimize the possibility of any adverse
impact on area development or the Chesterfield County Public Safety Trunked
System.
(NOTE: CONDITIONS MAY BE IMPOSED OR THE PROPERTY OWNER MAY PROFFER
CONDITIONS. THE CONDITIONS NOTED WITH "STAFF/CPC" WERE AGREED UPON
BY BOTH STAFF AND THE COMMISSION. CONDITIONS WITH ONLY A "STAFF" ARE
RECOMMENDED SOLELY BY STAFF. CONDITIONS WITH ONLY A "CPC" ARE
ADDITIONAL CONDITIONS RECOMMENDED BY THE PLANNING COMMISSION.)
CONDITIONS
(STAFF/CPC) 1.
Any communications tower use and equipment shall be designed and
installed so as not to interfere with the Chesterfield County Public
Safety Trunked System and the Utilities Department
communications system. Prior to site plan or building permit
approval, whichever occurs first, the owner/developer of non-
County communications equipment shall submit information as
deemed necessary by the Chesterfield County Communications and
Electronics staff and Utilities Department staff to determine if an
engineering study should be performed to analyze the possibility of
radio frequency interference with the County systems, based upon
the frequencies and effective radiated power generated by tower-
mounted equipment. Prior to release of a building permit, the
study, if required, shall be submitted to, and approved by, the
Chesterfield County Communications and Electronics staff and
Utilities Department staff. (GS and U)
2 01SN0145/WP/JAN24K
(STAFF/CPC)
(STAFF/CPC)
(STAFF/CPC)
(STAFF/CPC)
(STAFF/CPC)
The owner/developer of non-County communications equipment
shall be responsible for correcting any frequency problems which
affect the Chesterfield County Public Safety Trunked System and
Utilities Department communications system caused by this use.
Such corrections shall be made immediately upon notification by the
Chesterfield County Communications and Electronics staff or
Utilities Department staff. (GS and U)
The color and lighting system for the tank/tower shall be as follows:
The tank shall be grey or another neutral color, acceptable
to the Planning Department.
Any communications equipment (antennae, mounting
hardware, cabling, etc.) mounted on the outside of the water
storage tank structure shall be the same color as the water
storage tank.
Any lighting required by FAA shall be restricted as follows:
light'mg during daylight hours shall be limited to medium
intensity strobe lights with upward reflection; and lighting
during night time hours shall be limited to soft blinking
lights. (P)
Any building or mechanical equipment shall comply with Sections
19-570 (b) and (c) and 19-595 of the Zoning Ordinance relative to
architectural treatment of building exteriors and screening of
mechanical equipment. (P)
(NOTE: This condition would require the screening of mechanical
equipment, located on, or associated with, any building from
adjacent properties and public rights of way. This condition would
not require screening for the tower or tower-mounted equipment or
for ground-mounted equipment cabinets.)
At such time that any communications tower use ceases to be used
for communications purposes for a period exceeding twelve (12)
consecutive months, the owner/developer of the communications
equipment shall dismantle and remove the antennas and all
associated equipment from the property. (P)
In conjunction with the approval of this request, a thirty (30) foot
exception to the 150 foot height limitation for communication
3 01SN0145/WP/JAN24K
(STAFF/CPC) 7.
towers and water storage tanks in an Agricultural (A) District shall
be granted; provided, however, if communications antennae are
placed on the top of the water storage tank, the height of the
antennae shall be limited to ten (10) feet. (P)
The communications tower use shall be permitted only if it is
incorporated into the structure of the existing water tank. All
cabling shall be housed in conduit or otherwise shielded from view.
(P)
(Note: With the exception of Condition 1, all other existing
conditions of Case 89SN0242 remain in effect.)
GENERAL INFORMATION
Location:
Fronts the north line of Midlothian Turnpike, west of Huguenot Springs Road.
710-710-Part of 0358 and 711-709-0391 (Sheet 5).
Tax ID
Existing_g_q_n_Lag:
A
Size:
2.3 acres
Public/Semi-public (water storage tank)
Adjacent Zoning and Land Use:
North - A with Conditional Use to permit outdoor recreational facilities; Commercial
South - A and A with Conditional Use to permit outdoor recreational facilities;
Commercial or vacant.
East - A; Public/semi-public (Bethel Baptist Church)
West - A with Conditional Use to permit outdoor recreational facilities; Commercial
4 01SN0145/WP/JAN24K
UTILITIES
Public Water System:
The proposed water storage tank is needed to provide increased water pressure and fire
flows along the western Midlothian Turnpike Corridor, and will be designed to meet
growing demand and service conditions caused by higher ground elevations in the pressure
zone. It is anticipated that the new tank will not be built until the existing tank is
demolished.
Public Wastewater System:
The facility will not require the use of the public wastewater system.
ENVIRONMENTAL
The site drains to the northeast and then west via tributaries into Powhatan County before
entering the James River. There are no existing or anticipated on- or off-site drainage or
erosion problems.
PUBLIC FACILITIES
Fire; Police; and Transportation:
The proposed use will have a minimal impact on fire/rescue services, police and the
transportation network.
COUNTY COMMUNICATIONS
Currently, the Zoning Ordinance requires that any structure over eighty (80) feet in height be
reviewed by the County's Public Safety Review Team for potential detrimental impacts the
structure could have on the County's Radio Communications System microwave paths. This
determination must be made prior to erection of any water storage tank or communications
antennae on the water storage tank. As noted herein, any communications tower use would be
incorporated into an existing water storage tank.
A preliminary review of this proposal has indicated that the facility will not interfere with the
County's communications system; however, if this request is approved, a condition should be
imposed to ensure that the tank and antennae are designed and constructed so as not to interfere
with the Chesterfield County Public Safety Trunked System (Condition 1). In addition, once the
5 01SN0145/WP/JAN24K
use is erected, if interference occurs, the owner/developer should be required to correct any
problems. (Condition 2)
COUNTY AIRPORT
A preliminary review of this proposal has indicated that, given the approximate location and
elevation, it appears the tank will not adversely affect the Chesterfield County Airport.
LAND USE
Comprehensive Plan:
Lies within the boundaries of the Route 288 Con'idor Plan which suggests the property is
appropriate for neighborhood mixed use which includes neighborhood commercial type
uses and the area surrounding the request site is suggested for regional employment center
uses to include office, research and development uses, warehouses and light industrial
USES.
The 'cF~, an element of the Comprehensive Plan, suggests that energy and
communications uses should be located to minimize impacts on existing and future areas
of development and that such uses should co-locate whenever feasible. Such co-location
would be appropriate for other tall structures, such as the proposed water storage tank.
The Plan also suggests that additional water storage tanks should be constructed to serve
the County's water supply system by 2015.
Area Development Trends:
Surrounding properties to the north, south and west are zoned Agricultural (A) with
Conditional Use and are developed for commercial outdoor recreational uses (Windy Hill
Sports Complex). Property to the east is zoned Agricultural (A) and is developed with a
public/semi-public use (Bethel Baptist Church). With the extension of Route 288 to Route
60, it is anticipated that this area will experience future pressure for office and light
industrial developments that are dependent upon the use of public facilities and consistent
with the goals of the Route 288 Corridor Plan.
On June 28, 1989, the Chesterfield County Board of Supervisors approved a Conditional
Use Planned Development to permit an above-ground water storage tank and associated
bulk exceptions. The approved master plan specified a height of 110 feet for this facility.
6 01SN0145/WP/JAN24K
Site Design:
The site lies to the north of Midlothian Turnpike. Access to the site is proposed from
Midlothian Turnpike via a gravel road to the south of the tank site. A water storage tank
is planned. Approval of this request would also allow communications antennae on the
water storage tank structure.
Existing Conditions 3 and 4 of Case 89SN0242 require that the base of the tank be secured
with a fence to discourage trespassing and the area surrounding the base of the tower be
landscaped.
Architectural Treatment:
The request property lies within an Emerging Growth Area. A condition should be
imposed to require compliance with Emerging Growth requirements relative to
architectural treatment of buildings and screening of mechanical equipment. (Condition 5)
Specifically, within Emerging Growth Areas based on current Ordinance requirements,
no building exterior which would be visible to any A District or any public right of way
may consist of architectural material inferior in quality, appearance or detail to any other
exterior of the same building. There is, however, nothing to preclude the use of different
materials on different building exteriors, but rather, the use of inferior materials on sides
which face adjoining property. No portion of a building constructed of unadorned concrete
block or corrugated and/or sheet metal may be visible from any adjoining A District or any
public right of way. No building exterior may be constructed of unpainted concrete block
or corrugated and/or sheet metal.
All junction and accessory boxes must be minimized from view of adjacent property and
public rights of way by landscaping or architectural treatment integrated with the building
served. Mechanical equipment, whether ground-level or rooftop, must be screened from
view of adjacent property and public rights of way and designed to be perceived as an
integral part of the building. These requirements would not apply to any tower or tower-
mounted equipment.
In response to concerns by the Midlothian District Commissioner, a condition was imposed
by the Planrdng Commission to limit the height of any antennae on the top of the water
tank to ten (10) feet. (Condition 6)
In addition, consistent with past actions on similar facilities, any communications
equipment should be removed at such time that it ceases to be used for communications
purposes to ensure that the equipment does not become a maintenance problem or an
eyesore. (Condition 6)
7 01SN0145/WP/JAN24K
Screening:
Antennae, cabling and other equipment associated with communications tower use, if
mounted on vertical elements of the water tank and having the same color as the tank,
should not create a visual impact significantly greater than the visual impact of the water
tank mass (Conditions 3 and 7). The applicant has submitted an elevation depicting the
proposed location and screening of the communications antennae. Adherence to this
particular design is not required; however, a condition should be imposed requiring any
communications antennae be incorporated into the water storage tank structure and not a
freestanding structure. (Condition 7)
The proposed water storage tank which replaces an existing facility will meet the increasing water
demand pressure and fire flow needs in the Midlothian area. The Public Facilities Plan suggests
that communications tower locations should generally be located to minimize the impact on
existing or planned areas of development, and that communications facilities should co-locate
whenever feasible. Specifically, any communications antennae would be incorporated into the
proposed water storage tank. The addition of the communications facilities would not generate
a visual impact on area residences that is significantly greater than the visual impact of the
proposed water tank and conforms to the co-location criteria of the Plan.
In addition, incorporating the communications facilities into a proposed water storage tank will
eliminate the need for an additional freestanding communications tower in the area, thereby
minimizing tower proliferation. Similar co-locations have occurred in areas throughout the
County, with no known adverse impacts on nearby development. Specifically, several
communications tower/water tank structure co-locations have been approved, with no known
adverse in, pacts on area neighborhoods. The recommended conditions will further minimize the
possibility of any adverse impact on area development or the Chesterfield County Public Safety
Trunked System.
Given these considerations, approval of this request is recommended.
CASE HISTORY
Staff and the Midlothian District Commissioner (12/19/00):
At the request of the Midlothian District Commissioner, Staff prepared modified conditions
to limit the height of any antennae mounted on the top of the tank and to delete any
screening requirements for communication antennae.
8 01SN0145/WP/JAN24K
Planning Commission Meeting (12/19/00):
The applicant's representative accepted the recommendation. There was no opposition
present.
On motion of Mr. Gecker, seconded by Mr. Litton, the Commission recommended
approval of this request subject to the conditions on pages 2 through 4.
AYES: Unanimous.
Further, the Commission found this facility to be in substantial accord with the
Comprehensive Plan. The Code of Virginia, as amended, grants the Board authority to
"Overrule the action of the Commission by a majority vote of the membership thereof."
The Board of Supervisors, on Wednesday, January 24, 2001, beginning at 7:00 p.m., will take
under consideration this request.
9 01SN0145/WP/JAN24K
A
C V
A
C
A
0
600 Feet
01SN0145
AMEND C.U.P.D.
Sheet #: 5
~ /~00
MI'DLOTHIAN
( u. ~,. ,,..ou'~- c,,o)
APPROVED MASTER PLAN
FIO'+
WL=534':1:
ACCESS
TUBE I
100'-0"±
/ VACUUM RELIEF
OVERFLOW
ROOF ACCESS
LADDER WlTH
SAFETY CLIMB
SILT STOP
LWI.
RING BEAM
REINFORCED
STRUCTURAL SLAB
INLET/OUTLET
FLAP VALVE ~ j
SPLASH PAD.~,,
.ITIJRE CELLULAR
COMMUNICATIONS
ANTENNAS
ACCESS
HATCH
DRAIL
L PAINTER'S RAIL--
- STEE
RO01
TANK
rANK ACCESS
LADDER WITH
SAFL I Y CLIMB
DIA. ACCESS
3'UBE
MANHOLE
TANK
SHELL
;TEEL TANK FLOOR
PLATE
UPPER LANDING
W~TH HANDRAIL
SLAB ON
GRADE
5~.'_0"+
~AINTER'SRAIL ~
.I
PAINTER'S L~R ~
WI~ IN~CTSGRE~
ACCE~LADDER
LADDER UGHTING
LADDER WITH
SAFETY RAIL
.. . REINFORCED
CON CE['. I ~'
SUPPORT WALL
STORAGE FLOOR
(OPTIONAL)
~IN IIr.,RIOR BASE
LIGHTS
FINISH GRADE=Sg4':E
SLOPE AWAY FROM
TANK
Ol 5NO I~r5 -~.