17SN0505
CASE NUMBER: 17SN0505
APPLICANT: Amy D. Varela
CHESTERFIELD COUNTY, VIRGINIA
STAFF’S ANALYSIS Magisterial District: MIDLOTHIAN
17401 Midlothian Turnpike
AND
RECOMMENDATION
Board of Supervisors (BOS)
Public Hearing Date:
DECEMBER 14, 2016
BOS Time Remaining:
365 DAYS
Applicant’s Contact:
AMY D. VARELA
(804-943-8329)
Planning Department Case Manager:
DARLA ORR (804-717-6533)
APPLICANT’S REQUEST
Rezoning from Community Business (C-3) and Agricultural (A) to General Business (C-5) with
Conditional Use Planned Development to permit exceptions to ordinance requirements.
Specifically, exceptions are requested to setbacks, parking, screening, loading areas, landscaping
and outside display in the Employment Center Design District.
Commercial uses are planned. Uses would be limited to those uses permitted in the Community
Business (C-3) District and certain General Business (C-5) uses, including automobile and motor
cycle sales, service and repair, carport and utility trailer sales and contractor’s office and storage
yard.
Notes:
A. Conditions may be imposed or the property owner may proffer conditions.
B. Proffered conditions, Textual Statement and an exhibit are located in Attachments 1 thru 3.
RECOMMENDATIONS
RECOMMEND APPROVAL
PLANNING
Permits continued commercial use with limitations
COMMISSION
(11/15/2016)
Consistent with existing C-5 zoning north of Midlothian Turnpike
RECOMMEND DENIAL
Proposed zoning and land use represent a deviation from the
corporate office/research and development/light industrial land
STAFF
use suggested by the Comprehensive Plan.
Proposed land use inconsistent with existing and anticipated area
development
Providing a FIRST CHOICE community through excellence in public service
SUMMARY OF IDENTIFIED ISSUES
Department Issue
Zoning and land use are a deviation from the corporate
office/research and development/light industrial land use
suggested by the Comprehensive Plan
Expanded commercial uses could set a precedent for further
PLANNING strip commercial development in the area, thereby impacting
parcel aggregation for future office, research and development
and light industrial uses as suggest by the Comprehensive Plan
Permits expansion of uses with minimal site improvements
typically required for new developments
217SN0505-2016DEC14-BOS-RPT
317SN0505-2016DEC14-BOS-RPT
Map 2: Comprehensive Plan
Classification: CORPORATE OFFICE/RESEARCH & DEVELOPMENT/LIGHT INDUSTRIAL
This designation suggests the property is appropriate for corporate office, research and light
manufacturing uses without outside uses or storage. Aggregation and master planning is suggested
to enhance economic potential, overall design and coordinated access and road plans.
Map 3: Surrounding Land Uses & Development
Frameway Rd
Commercial,
residential uses and
vacant; zoned A, C-5
and I-1
County Line Rd
Single family residential and
agricultural use; zoned O-2
MidlothianTpk
417SN0505-2016DEC14-BOS-RPT
PLANNING
Staff Contact: Darla Orr (804-717-6533) orrd@chesterfield.gov
ZONING HISTORY
Case Number BOS Action Request
Approved Zoned 1.3 acres of subject property from Agricultural (A)
84SN0002
2/22/1984 to Community Business (C-3)
Conditional Use Planned Development to permit
sale and repair of motorcycles and sale of
motorcycle trailers and accessories
Exceptions granted specific to motorcycle sales,
Approved
repair and trailer and accessory sales. Exceptions
85SN0080
7/24/1985
permit a 5 ft. setback for outside display from
Midlothian Turnpike and size and paving of parking
Conditions limited outside display to 5 items,
prohibited additions/alterations to building, and
addressed screening, storage and site layout
PROPOSAL
The applicant proposes rezoning of the request property to General Business (C-5) to permit
commercial usestypically associated with increased outside storage and display. Permitted
uses would be limited to uses permitted in the Community Business (C-3) District plus certain
General Commercial (C-5) uses. The applicant has indicated she desires the rezoning to be able
to better market the property for leasing. She stated she has a pending three (3) year lease
agreement with a landscaping contractor who installs decorative patios.
The principal structure on the property was constructed in 1940 and is considered a non-
conforming structure relative to setbacks. Other improvements have been made to the
property owner time, many of which do not comply with current Ordinance standards.
Exceptions, as outlined in the Textual Statement, are requested to Zoning Ordinance
requirements to document these improvements which may remain but cannot be expanded or
altered without complying with ordinance standards. These existing structures, as well as
planned outside display and storage areas are identified on Exhibit A in Attachment 3.
Exceptions are requested relative to screening, size and treatment of parking and side setbacks
and setbacks from Midlothian Turnpike for existing buildings, outside display, parking and
drives.
Except as permitted in the Textual Statement (Attachment 2), development of the property
shall comply with the standards of the Employment Center Design District which address
screening, landscaping, setbacks, and building heights. These standards would affect any
redevelopment of the property, which includes, although not exclusively, construction of any
new buildings and/or building additions or alterations, and any additional parking or drives.
517SN0505-2016DEC14-BOS-RPT
The following provides an overview of the development’s design standards:
General Overview
Requirements Details
Textual Statement is the master plan
Master Plan
Proffered Condition 1
Limited to C-3 usesand certain C-5 uses
Uses
Proffered Condition 2
Permitted accessory to a permitted use provided:
Outside storage is located behind the existing
principal building and is screened
Outside Storageand Display
Outside display is located in the area identified on
Exhibit A
Proffered Conditions 2, 3, 4 and Textual Statement
617SN0505-2016DEC14-BOS-RPT
FIRE SERVICE
Staff Contact: Anthony Batten (717-6167) battena@chesterfield.gov
This request will have minimal impact on Fire and EMS.
Nearby Fire and Emergency Medical Service (EMS) Facilities
Fire Station The Midlothian Fire Station, Company Number 5
EMS Facility The Forest View Volunteer Rescue Squad
COUNTY DEPARTMENT OF TRANSPORTATION
Staff Contact: Jim Banks (804-748-1037) banksj@chesterfield.gov
The Comprehensive Plan, which includes the Thoroughfare Plan, identifies county-wide
transportation needs that are expected to mitigate traffic impacts of future growth. The
anticipated traffic impact of the proposal has been evaluated and it is anticipated to be
minimal.
VIRGINIA DEPARTMENT OF TRANSPORTATION
Staff Contact: Brian Lokker (804-674-2384) brian.lokker@vdot.virginia.gov
VDOT has no comment on this case.
717SN0505-2016DEC14-BOS-RPT
WATER AND WASTEWATER SYSTEMS
Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov
The proposal’s impacts on the County’s utility system are detailed in the chart below:
Water and Wastewater Systems
Currently Size of Closest Connection Required by County Code
Serviced Existing Line
Water Yes 16”Yes
Wastewater No NA No
Utilities Issues
This site is in the mandatory water and sewer connection area. Any new
structures will be required to connect to sewer. Sewer is currently
located approximately 10,500’ from property.
The proposed request will not impact the public water and wastewater
systems.
ENVIRONMENTAL ENGINEERING
Drainage, Erosion and Water Quality
Staff Contact: Rebeccah Ward (748-1028) wardr@chesterfield.gov
Stormwater
Issue Discussion/Conditions
Located within the Upper Swift Creek Watershed
Geography
Property drains to a natural channel which discharges to an
unnamed tributary to Swift Creek
Prior to any proposed improvements or site plan approval, a
Environmental
Natural Resources Inventory (NRI) and Resource Protection Area
Issues
Designation (RPAD) must be submitted and reviewed by the
Department of Environmental Engineering-Water Quality Section
If greater than 2,500 square feet of total land disturbance will
Erosion and
occur as a result of any proposed improvements, a land
Sediment Control
disturbance permit will be required
If greater than 2,500 square feet will be disturbed with any
Stormwater
proposed improvements, the project will be subject to the Part
Management
IIB technical criteria of the Virginia Stormwater Management
Program Regulations for water quality and quantity
817SN0505-2016DEC14-BOS-RPT
CASE HISTORY
Applicant Submittals
7/8/2016 Initial application submitted
11/7/2016 Revised proffered conditions submitted
Community Meetings
9/12/2016 Issues Discussed
Proposed uses
Hours of operation
Prohibition on nightclubs
11/7/2016 Issues Discussed
Proposed uses, their locations and development standards
Concern with nightclubuse
Planning Commission Meeting
11/15/2016
Citizen Comments
One citizen spoke in opposition expressing concerns relative to:
Precedent C-5 zoning may set for additional C-5 zoning in area
o
Effects on marketability of family-owned adjacent O-2 property
o
Traffic
o
Activities such as with nightclub use and other C-5 uses that would be
o
permitted
Commission Discussion
Mr. Jones noted two community meetings were held on this request. He
advised in consideration of existing area C-5 zoning to the north; the history
of the property’s commercial use; the proffered limitations; and the
potential for future parcel aggregation with adjacent O-2 property for
redevelopment, he was supportive of the request.
Recommendation – APPROVAL AND ACCEPTANCE OF THE
PROFFERED CONDITIONS IN ATTACHMENT 1
Motion: Jones Second: Freye
AYES: Wallin, Sloan, Frye, Jackson and Jones
The Board of Supervisors on Wednesday, December 14, 2016, beginning at 6:30 p.m., will
consider this request.
917SN0505-2016DEC14-BOS-RPT
ATTACHMENT 1
PROFFERED CONDITIONS
Note:
The Planning Commission recommends acceptance of the following proffered conditions
offered by the applicant
1. The Textual Statement dated October 24, 2016 shall be considered the master plan. (P)
2. The following uses shall be permitted:
A. Except as provided herein, uses permitted in the Community Business (C-3)
District.
B. Automobile (including motorcycle) sales, service and repair; excluding body,
major engine and transmission repair and consignment sales, provided:
i. Except for minimal repairs necessary to allow a vehicle to be moved into
a service area, repair activities and storage of new or replaced repair
materials shall occur inside a building.
ii. Elevated display of automobiles shall not occur.
iii.A maximum of fifteen (15) vehicles for sale shall be permitted at any one
time to be displayed outside of a building. Such display shall only occur
within the area identified as “Display Area” on Exhibit A and as outlined
herein.
C. Contractor’s shop and storage yard, provided any associated outside
equipment/material storage shall only occur in the area identified as “Storage
Area” on Exhibit A and as outlined herein.This does not preclude contractors
from having outside displays of products (such as a landscaped outdoor patio)
provided such display shall only occur in the area identified as “Display Area” on
Exhibit Aand as outlined herein.
D. Electrical, plumbing or heating supply sales, service and related display rooms.
E. Carport sales provided only one (1) carport shall be permitted to be displayed
outside of a building. Such display shall only occur within the area identified as
“Display Area” on Exhibit A and as outlined herein.
F. Utility trailer sales, service and repair provided a maximum of five (5) utility
trailers for sale shall be permitted to be displayed outside of the building. Such
display shall only occur within the area identified as “Display Area” on Exhibit A
and as outlined herein. (P)
3.Outside Display: Outside display shall only be permitted accessory to uses permitted in
Proffered Condition 2.B. through F. and only in the area identified as “Display Area” on
Exhibit A. Such display area shall not exceed 30 feet by 40 feet in area. The display is
reserved for product display (such as with carport sales, patio display, and automobiles
for sale). Outside storage of equipment, parts or materials is not permitted within this
area. (P)
4.Outside Storage: Outside storage shall only be permitted as accessory to a permitted
use; shall only be permitted behind the existing principal building in the area identified
1017SN0505-2016DEC14-BOS-RPT
as “Outside Storage Area” on Exhibit A; and shall be screened in accordance with the
requirements of the Zoning Ordinance. (P)
1117SN0505-2016DEC14-BOS-RPT
ATTACHMENT 2
TEXTUAL STATEMENT
October 24, 2016
I. The request property is located within the Employment Center Design District. Except
as outlined herein to accommodate use of the existing buildings, parking and drives as
identified on Exhibit A, development of the property shall comply with the Zoning
Ordinance standards for the Employment Center Design District. Development of the
property shall be any redevelopment of the property to include any new buildings,
building additions or alterations (except as required to provide necessary
accommodations for the handicapped such as ramps), and construction of any
additional parking or drives.
II. Use of Existing Garage Bays Oriented Towards Midlothian Turnpike
Use of existing garage bays on the principal building, as identified on Exhibit A, for
loading or repair of vehicles or equipment in conjunction with a permitted use shall be
permitted provided the middle access to Midlothian Turnpike shall be closed and a
landscaped area shall be provided to minimize view of such bays. Prior to use of the
existing garage bays, an access closure and landscaping plan shall be submitted to the
Planning Department for review and approval. Such approved landscaping shall be
installed in accordance with the landscaping plan. Any redevelopment of the property
shall require any garage bay doors to be screened in accordance with the Zoning
Ordinance requirements for loading areas.
III. Motorcycle Parking
Should the property be used for motorcycle sales, service and repair, a maximum of ten
(10) parking spaces shall be permitted to be reduced in size to three (3) feet in width
and six (6) feet in length to accommodate parking for motorcycles.
IV. Setbacks for Existing Structures, Parking and Drives (as identified on Exhibit A) – Except
as outlined below, buildings, parking and drives shall comply with Zoning Ordinance
standards:
A. The existing principal structure shall have setback from Midlothian Turnpike of a
minimum of fifteen (15) feet.
B. The existing parking shall have a setback from Midlothian Turnpike of a
minimum of fifteen (15) feet and a side yard setback from the western property
boundary of a minimum of eight (8) feet.
C. There shall be no minimum setback for the existing drive from Midlothian
Turnpike and a side setback from the western property boundary of a minimum
of seven (7) feet and from the eastern property boundary a minimum of 10 feet.
1217SN0505-2016DEC14-BOS-RPT
D. There shall be no parking permitted within the front setback between the
existing principal building and Midlothian Turnpike.
V.Standards for Outside Display Area –Except as outlined below, the display area shall
comply with Zoning Ordinance standards:
A. Outside display shall be permitted as outlined in the proffered conditions and as
identified on Exhibit A. Such area shall be setback from Midlothian Turnpike a
minimum of twenty-five (25) feet.
B. The display area as identified on Exhibit A shall have a surface treatment of a
minimum of six (6) inches of No. 21 or No. 21A stone or similar materials as may
be approved by the Planning Department.
C. Landscaping shall be installed to soften view of the display area from Midlothian
Turnpike. Within thirty (30) days of the approval of this request, a landscaping
plan shall be submitted to the Planning Department for review and approval.
Such approved landscaping shall be installed within 120 days of the approval of
this request. Any redevelopment of the property shall require all outside display
areas to comply with Zoning Ordinance standards.
VI. Existing Shed
The existing 8 foot by 12 foot shed identified on Exhibit A shall remain but shall not be
expanded or altered unless in compliance with Zoning Ordinance standards.
VII. All existing parking areas, as identified on Exhibit A shall have a surface treatment of a
minimum of six (6) inches of No. 21 or No.21A stone. Any redevelopment or expansion
of the parking area shall require all parking to comply with Zoning Ordinance standards.
1317SN0505-2016DEC14-BOS-RPT
ATTACHMENT 3
EXHIBIT A
Middle Entrance
Middle Entrance
Closure &
Closure & Landscaping
Landscaping
Existing
Parking Area
Existing
8’ X 10’ shed
Outside
Storage
30’ X 40’
Area
Display Area
1417SN0505-2016DEC14-BOS-RPT