Loading...
17SN0602 CASE NUMBER: 17SN0602 (AMENDED) APPLICANTS: First Market Bank, FSB aka Union Bank and Trust and Johnson Development Association, Inc. CHESTERFIELD COUNTY, VIRGINIA CLOVER HILL DISTRICT STAFF’S ANALYSIS AND RECOMMENDATION Board of Supervisors Hearing: MAY 24, 2017 Board of Supervisors Time Remaining: 365 DAYS Applicants’ Agent: JACK R. WILSON (804-425-9474) Applicants’ Contact: JOHNSON DEVELOPMENT ASSOCIATION, 4 Acres – 6500 Branch Point Drive INC. (804-497-2730) Planning Department Case Manager: RYAN RAMSEY (804-768-7592) REQUEST (AMENDED) Rezoning from Corporate Office (O-2) to General Business (C-5) plus conditional use planned development to permit exceptions to ordinance requirements relative to development standards. Specifically, exceptions to maximum building height and buffer widths are requested. Notes: A. Conditions may be imposed or the property owner may proffer conditions. B. Proffered conditions, a textual statement, conceptual layout, and conceptual elevations are located in Attachments 1 - 4. SUMMARY An indoor self-storage facility is planned. Proffered Condition 3 limits uses to an indoor self-storage facility. Exceptions would permit: Building height, limited to the lesser of 2 stories or thirty (30) feet within 200 feet of an existing residential development, to be increased to the lesser of three (3) stories or forty- five (45) feet; and A vegetative buffer along the western property line to be reduced from 100 to thirty (30) feet in width. RECOMMENDATIONS PLANNING APPROVAL COMMISSION APPROVAL Given the location, use limitations and conditions ensuring quality architectural STAFF design and materials and compatibility with area development, the proposed zoning and land use are appropriate. Providing a FIRST CHOICE community through excellence in public service 217SN0602-2017MAY24-BOS-RPT Comprehensive Plan Classification: COMMUNITY BUSINESS The designation suggests the property is appropriate for commercial uses that serve community-wide trade areas. Surrounding Land Uses and Development Single-family Uses Commercial & Office Uses (Watch Hill Subdivision) Hull Street Road Career & Clover Technical Hill Fire Center at Hull Station Harbour View Court Branch Point Drive 317SN0602-2017MAY24-BOS-RPT PLANNING Staff Contact: Ryan Ramsey (804-768-7592) ramseyrp@chesterfield.gov Zoning History Case Number Request Rezone to Corporate Office (O-2) to permit office uses (with specified uses prohibited) 03SN0243 Proffered conditions minimized impacts on neighboring residential Approved development. These included limitationson uses, building location and (06/2003) height, landscaping, buffers, and architectural compatibility with neighboring office development. Proposal The applicants propose to rezone the property to General Commercial (C-5) to permit an indoor self-storage facility. A conceptual plan is offered to ensure adequate separation of the facility from the adjoining Watch Hill Subdivision located to the north(Exhibit A, Attachment 3). Permitted uses would also be limited to an indoor self-storage facility with no outside storage. Given the following, staff finds the proposed land use acceptable as appropriate: Property is located on the northern edge of the Community Business land use designation whereby the Comprehensive Plan supportstransitionaluses Site layout, architectural design and materia and facility orientation away from area residential development minimize area impacts and ensure compatibility with area office development Uses are limited to the indoor self-storage facility and access to the site would be from Hull Street Road (Route 360), via Branch Point Drive The following provides an overview of the development’s design standards: General Overview Requirements Details Master Plan offered in the form of a Textual Statement Master Plan & Site Plan Proffered Condition 1 (Attachment 2) Development generally in conformance with plan Proffered Condition 2 Indoor self-storage warehouse only No outside storage Uses No units used for office or dwelling purposes Proffered Condition 3 Minimum rear yard building setback of 100 feet Setback Proffered Condition4 417SN0602-2017MAY24-BOS-RPT General Overview(Continued) Requirements Details Style and materials consistent with renderings offered and described in the “Architecture & Building Architecture and Materials Materials” section Proffered Condition 5 and Attachment 3 Maximum height 15 feet Lighting Proffered Condition 6 Daily 6:00 a.m.to 10:00 p.m. Hours of Operation Proffered Condition 7 Cannot exceed 55 dBa at property line Noise Proffered Condition 8 Architecture & Building Materials Proffered building design incorporates characteristics ofnearby commercial and office buildings. Elevations would require use of materials found in the adjoining commercial and office development, includingmasonry, metal standing-seam roof accent along the front and portions of the side elevations, and glazed windows (Attachment 4). A combination of real and simulated windows has been provided on all sides of the building to appear more like an office building. This building design would be compatible with area office and commercial development. Building Height Building and parking area improvements on the request property would be regulated by Route 360 West Design District standards for the General Business (C-5) District. The design district standards restrict the maximum building height to three (3) stories or forty-five (45) feet, whichever is less. In addition, buildings within 200 feet of a developed residential neighborhood are further restrictedto a maximum of two (2) stories or thirty (30) feet in height, whicheveris less. An exception to the maximum building height is requested to permit a maximum building height of three (3) stories or forty-five (45) feet for the entire property. A portion of the building would be within 200 feet of the Watch Hill Subdivision. To minimize the impact of the building on adjoining residential uses, the applicant has proffered a 100-foot building setback from the rear property line. In addition, while no buffer is required along the rear (northern) property boundary, a twenty (20) foot buffer is offered to enhance this setback area with landscaping. Buffers A 100-footbuffer is required along the western property line where neighboring properties are zoned Residential (R-7). A thirty (30) foot buffer is requested. The reduced buffer will be landscaped with a treatment consistent with a buffer that is fifty (50) feet wide (Textual Statement, Item 1). The adjoining properties are occupied by a fire station, a water tower or remain vacant, and are suggested by the Plan for Community Commercial (C-3) uses. 517SN0602-2017MAY24-BOS-RPT FIRE SERVICE Staff Contact: Anthony Batten (717-6167) battena@chesterfield.gov Nearby Fire and Emergency Medical Service (EMS) Facilities Fire Station The Clover Hill Fire Station, Company Number 7 EMS Facility The Clover Hill Fire Station, Company Number 7 When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. COUNTY DEPARTMENT OF TRANSPORTATION Staff Contact: Jim Banks (804) 748-1037 banksj@chesterfield.gov The Comprehensive Plan, which includes the Thoroughfare Plan, identifies county-wide transportation needs that are expected to mitigate traffic impacts of future growth. The anticipated traffic impact of the proposal has been evaluated and it is anticipated to be minimal. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Brian Lokker (804-674-2384) brian.lokker@vdot.virginia.gov This request will have minimal impact on transportation facilities. UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov Existing Water and Wastewater Systems Currently Size of Closest Existing Connection Required by County Utility Type Serviced Lines Code Water No 8” Yes Wastewater No 8” Yes Additional Utility Comments Located in the mandatory water and sewer connection area. Public water (eight (8) inch water line) is located along Branch Point Drive, and public sewer is located on site. 617SN0602-2017MAY24-BOS-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) wardr@chesterfield.gov Issue Discussion/Conditions The property is located within the Upper Swift Creek Watershed. The northern and westernportion of the property drains to an existing drainage easement and storm sewer system in the Watch Geography Hill Subdivision, which discharges into an unnamed tributary to the Swift Creek Reservoir. The southeastern portion of the property drains to an existing stormwater pond in the Harbour Pointe Village Shopping Center. As required by Section 19.1-542 of the Zoning Ordinance, a natural resource inventory (NRI) was reviewed and approved by the Department of Environmental Engineering for the proposed Natural Resources development site with the rezoning application. The NRI indicated the presence of steep slopes (greater than 25%) in the eastern portion of the site and a small wetland along the northern property line. Steep slopes greater than 20 percent are difficult to stabilize when disturbed. Disturbance of these slopes will result in increased Erosion and potential for sediment to impact natural resources if erosion occurs. Sediment Control The steep slopes in the eastern portion of the site shall remain in their natural, undisturbed state to the maximum extent practicable. The existing storm sewer system in the Watch Hill Subdivision should be evaluated to verify that existing private properties will not be negatively impacted with increased stormwater runoff created by the development. For the portion of the property which drains to the Watch Hill Drainage Subdivision, the maximum post-development discharge rate for the 100-year storm shall be based on the maximum capacity of the existing facilities downstream, and the recorded 100-year backwater and/or floodplain shall not be increased. Proffered Condition 9 717SN0602-2017MAY24-BOS-RPT Issue Discussion/Conditions To protect downstream properties from flooding in the event of a dam failure, any detention facility serving this portion of the site should be a dry facility below the existing ground so no manmade compacted embankment is required. If some level of manmade embankment is necessary, a dam failure analysis may be required Drainage showing no homes will be detrimentally impacted. The dam embankment design should include, but not be limited to, a clay core or a syphon structure. Proffered Condition 10 The southeastern portion of the property drains to an existing stormwater pond in the Harbour Pointe Village Shopping Center. The pond was designed to handle the drainage from this portion of Stormwater the property; however, it does not address water quality for the Management site. The development will be subject to the Part IIB technical criteria of the Virginia Stormwater Management Program Regulations for both water quality and water quantity. 817SN0602-2017MAY24-BOS-RPT CASE HISTORY Applicants Submittals 10/11/16 Application submitted 12/7/16 Proffered conditions were submitted 1/23/17 Revised proffers and textual statement were submitted 1/26/17 Revised application was submitted 2/1 & 2/27 Revisedproffers and textual statement were submitted 3/10/17 Revised proffers, textual statement, conceptual layout and elevations were submitted 3/29/17 Revised conceptual elevations were submitted 3/30/17 Revised proffers and textual statement were submitted Community Meeting 9/27/16Issues Discussed Access to Branch Point Drive & Route 360 Hours of operation, signage, lighting and building height Use limited to self-storage facility with outside storage prohibited Buffer and setback adjacent to rear property line Planning Commission 1/27/17Action – DEFERRED TO FEBRUARY 21, 2017 ON THEIR OWN MOTION WITH THE APPLICANTS’ CONSENT 2/21/17Action – DEFERRED TO MARCH 21, 2017 ON THEIR OWN MOTION WITH THE APPLICANTS’ CONSENT 3/21/17Action –DEFERRED TO APRIL 18, 2017 ON THEIR OWN MOTION WITH THE APPLICANTS’ CONSENT 4/26/2017 Citizen Comments: No citizens spoke to this request. Recommendation –APPROVAL AND ACCEPTANCE OF THE PROFFERED CONDITIONS IN ATTACHMENT 1 Motion: Freye Second: Wallin AYES: Sloan, Jackson, Freye, Jones and Wallin The Board of Supervisors on Wednesday, May 24, 2017, beginning at 6:00 p.m., will consider this request. 917SN0602-2017MAY24-BOS-RPT ATTACHMENT 1 PROFFERED CONDITIONS Note: Both the Planning Commission and Staff recommend acceptance of the following proffered conditions, as offered by the applicant. The property owner and applicant in this case, pursuant to Section 15.2-2298 of the Code of Virginia (1950 as amended) and the Zoning Ordinance of Chesterfield County, for themselves and their successors and assigns, proffer that the property under consideration (the "Property") will be developed according to the following proffers if, and only if, the request submitted herewith is granted with only those conditions agreed to by the owner and applicant. In the event this request is denied or approved with conditions not agreed to by the owner and applicant, the proffers shall immediately be null and void and of no further force or effect. 1.Master Plan. The textual statement dated March 31, 2017, shall be considered the Master Plan. (P) 2.Site Plan. The Property shall be developed in substantially the manner shown on the Site Plan, titled as “#6500 Branch Point Drive Self Storage”, attached as Exhibit A. (P) 3.Uses. Uses shall be limited to an indoor self-storage facility only. In conjunction with this use, outside storage and self-storage units used for office or dwelling purposes shall be prohibited. (P) 4.Setback. The rear yard building setback shall be a minimum of 100’. (P) 5.Elevations. The exterior facades of the improvements on the Property shall be substantially similar to the elevations shown on Exhibit B. (P) 6.Lighting. Light poles shall not exceed fifteen (15) feet in height. (P) 7.Hours of Operation. The hours of operation shall be no earlier than 6:00 a.m. and no later than 10:00 p.m. daily. (P) 8.Noise. Uses allowed on the property shall be designed and operated so as not to generate noise levels above 55 dBa at the property line. (P) 9.Post Development Discharge Rates. For the portion of the property which drains to the Watch Hill subdivision, the maximum post-development discharge rate for the 100-year storm shall be based on the maximum capacity of the existing facilities downstream, and the recorded 100-year backwater and/or floodplain shall not be increased. On-site detention of the post-development 100-year discharge rate to below the pre- development 100-year discharge rate may be provided to satisfy this requirement. (P) 10.Dam Failure Analysis.Any detention facility serving the site should be a dry facility below the existing ground so no manmade compacted embankment is required. If some level of 1017SN0602-2017MAY24-BOS-RPT manmade embankment is necessary, a dam failure analysis may be required, as determined by the Department of Environmental Engineering at the time of site plan review, showing no homes will be detrimentally impacted.The dam embankment design should include, but not be limited to, a clay core or a syphon structure. (P) 1117SN0602-2017MAY24-BOS-RPT ATTACHMENT 2 TEXTUAL STATEMENT March 31, 2017 1.The buffer on the western property line, adjacent to Tax IDs 726-673-8940 and 727-673-1202 shall be a minimum of thirty (30) feet and planted with a treatment for a fifty (50) foot-wide buffer, per the Zoning Ordinance. 2.The buffer on the northern property line, adjacent to Tax ID 727-673-1375 shall be a minimum of twenty (20) feet and planted with a treatment for a fifty (50) foot-wide buffer, per the Zoning Ordinance. 3.Building height shall be limited to a maximum of the lesser of 3 stories or forty- five (45) feet. 1217SN0602-2017MAY24-BOS-RPT ATTACHMENT 2 CONCEPTUAL SITE PLAN – EXHIBIT A 1317SN0602-2017MAY24-BOS-RPT ATTACHMENT 4 CONCEPTUAL ELEVATIONS – EXHIBIT B 1417SN0602-2017MAY24-BOS-RPT