Loading...
17SN0746 CASE NUMBER: 17SN0746 (AMENDED) APPLICANT: Dean T. Patrick CHESTERFIELD COUNTY, VIRGINIA DALE DISTRICT STAFF’S ANALYSIS AND RECOMMENDATION Board of Supervisors Hearing: MAY 24, 2017 Board of Supervisors Time Remaining: 365 DAYS Applicant’s Agent: ANDREW M. SCHERZER (804-794-0571) Applicant’s Contact: DEAN T. PATRICK (804-387-9124) 20.5 Acres – 6936 Autumn Point Drive Planning Department Case Manager: RYAN RAMSEY (804-768-7592) REQUEST (AMENDED) Amendment of zoning approval (Case 05SN0136) to amend cash proffers in a Residential (R-12) District. Specifically, the applicant proposes to delete Proffered Condition 2 relative to a cash proffer payment. Notes: A. The only condition that may be imposed is a buffer condition. The property owner may proffer conditions. B. A proffered condition and approved zoning conditions from Case 05SN0136 are located in Attachments 1 and 2. SUMMARY A single-family residential subdivision (Autumn Grove) is under development. There are 43 units included with this request, on which a cash proffer could be collected, in the amount of $18,318 per dwelling unit. Currently, the total potential value of the approved cash proffer equates to $787,674. With this request, the applicant is proposing to eliminate the cash proffer payment. Existing zoning conditions, and those proffered with this request provide design and architectural standards (Summarized on Pages 7 & 8) that are comparable in quality to the surrounding community. RECOMMENDATIONS PLANNING APPROVAL COMMISSION PLANNING AND TRANSPORTATION – APPROVAL Quality design and architecture provide for a convenient, attractive, and STAFF harmonious community. Located within a revitalization area. Under the Road Cash Proffer Policy, no road cash proffer will be accepted. Providing a FIRST CHOICE community through excellence in public service SUMMARY OF IDENTIFIED ISSUES Department Issue The Public Facilities Plan suggests revitalization or replacement of Falling Creek Middle School and a new high school facility in the vicinity of SCHOOLSChester Road and Route 288 north of Route 10, however at this time a budget has not been developed for the acquisition of land or construction of these school facilities as recommended in the Plan. The Public Facilities Plan suggests the Central Library should be expanded, replaced or a new facility shall be constructed in the general vicinity of LIBRARIES Kingsdale, Chester and Hopkins Roads. Land for expansion or replacement of this facility has not been acquired. 217SN0746-2017MAY24-BOS-RPT 317SN0746-2017MAY24-BOS-RPT TABLE A REQUEST PROPERTIES Tax Identification Number Address 774-678-7696 5937 AUTUMNLEAF DR 774-678-7787 5931 AUTUMNLEAF DR 774-678-7978 5925 AUTUMNLEAF DR 774-678-8069 5919 AUTUMNLEAF DR 774-678-8260 5913 AUTUMNLEAF DR 774-678-8552 5907 AUTUMNLEAF DR 774-678-9044 5901 AUTUMNLEAF DR 774-678-9235 5861 AUTUMNLEAF DR 774-678-9426 5855 AUTUMNLEAF DR 774-678-9693 5930 AUTUMNLEAF DR 774-678-9717 5849 AUTUMNLEAF DR 774-678-9985 5924 AUTUMNLEAF DR 774-679-7237 5961 AUTUMNLEAF DR 774-679-7249 5967 AUTUMNLEAF DR 774-679-7417 5949 AUTUMNLEAF DR 774-679-7427 5955 AUTUMNLEAF DR 774-679-7506 5943 AUTUMNLEAF DR 774-679-8252 5972 AUTUMNLEAF DR 774-679-9221 5948 AUTUMNLEAF DR 774-679-9302 5936 AUTUMNLEAF DR 774-679-9312 5942 AUTUMNLEAF DR 774-679-9330 5954 AUTUMNLEAF DR 774-679-9348 5966 AUTUMNLEAF DR 774-679-9639 5960 AUTUMNLEAF DR 775-677-0299 5837 AUTUMNLEAF DR 775-677-0490 5831 AUTUMNLEAF DR 775-677-0581 5825 AUTUMNLEAF DR 775-677-0758 5819 AUTUMNLEAF DR 775-677-2445 5806 AUTUMNLEAF DR 775-677-2864 5812 AUTUMNLEAF DR 775-677-2892 5830 AUTUMNLEAF DR 775-677-3073 5818 AUTUMNLEAF DR 775-677-3083 5824 AUTUMNLEAF DR 775-678-0008 5843 AUTUMNLEAF DR 775-678-0276 5918 AUTUMNLEAF DR 775-678-0467 5912 AUTUMNLEAF DR 775-678-0759 5906 AUTUMNLEAF DR 775-678-1249 5812 KOUFAX DR 775-678-1530 5813 KOUFAX DR 775-678-2019 5848 AUTUMNLEAF DR 775-678-2310 5842 AUTUMNLEAF DR 417SN0746-2017MAY24-BOS-RPT REQUEST PROPERTIES(CONTINUED) Tax Identification Number Address 775-678-2432 5807 KOUFAX DR 775-678-2601 5836 AUTUMNLEAF DR 517SN0746-2017MAY24-BOS-RPT Comprehensive Plan Classification: SUBURBAN RESIDENTIAL II, COMMUNITY MIXED USE & MEDIUM- HIGH DENSITY RESIDENTIAL The designation suggests the property is appropriate for residential use with a maximum of 2 to 4 dwelling units per acre; an integrated mixture of concentrated commercial and higher density residential uses with public spaces, located on tracts having sufficient size to accommodate such mixtures; and Various residential types including, but not limited to, single family, two- family, zero lot line, townhouse, condominium and multifamily dwellings. Surrounding Land Uses and Development Single-family uses (Autumn Grove Subdivision) Vacant Single-family uses (Stonebridge Subdivision) Route 10 Autumn Point Drive 617SN0746-2017MAY24-BOS-RPT PLANNING Staff Contact: Ryan Ramsey (804-768-7592) ramseyrp@chesterfield.gov Zoning History Case Number Request Rezoning to Residential (R-12)to permit a single-family development containing a maximum of eighty (80) dwelling units. Conditions included a cash proffer of 05SN0136 $11,500 per unit (escalated by the Marshall and Swift Building Cost Index, Approved amount is currently $18,318) to be allocated to roads, parks, libraries, fire (6/2005)stations and schools. (Proffered Condition 2) This staffreport for Case 05SN0136 analyzed the impact of the proposed development on public facilities and the applicant’s offer to mitigate that impact. Proposal Single-family residential uses are proposed. An overall maximum of eighty (80) dwelling units are permitted with the approved zoning. Seventy-eight (78) lots are recorded within the boundaries of the original zoning request, of which forty-three (43) would be impacted by this request. Design Requirements of Case 05SN0136 The following provides an overview of the approved design requirements referenced in attached case information (Attachment 2): Minimum house sizes Brick or stone veneer foundations Design High quality residential development addresses the Comprehensive Plan goals for strong and sustainable neighborhoods that are visually attractive, well-planned and well-maintained. Further, the purpose and intent of the zoning ordinance to promote the health, safety, convenience and general welfare of the public includes the creation of convenient, attractive and harmonious communities, protection against overcrowding of land, and protection of the natural environment. As such, developments that promote unique, viable and long lasting places and enhance the community are encouraged. The following provides an overview of additional design requirements offered as part of this request (Attachment 1 - Proffered Condition): Architectural styles compatible to homes constructed in the Autumn Grove subdivision Varied architectural style for dwellings located side-by-side or directly across a street 30-year architectural/dimensional roof shingles Maximum projection for front-loaded garages from front facade; upgraded garage door treatments for front and corner-side loaded garages 717SN0746-2017MAY24-BOS-RPT Step-down siding permitted under unique topographical situations with restrictions on the minimum exposed foundation, location, and size of the step-downs clarified Variety of siding materials to include vinyl with minimum thickness of 0.042 inches Front and rear porch treatments, if provided Front foundation planting beds and installation or retention of a front yard tree Concrete orasphalt driveways and concrete front walks As suggested by the Comprehensive Plan goals and zoning ordinance, the proffered conditions of this current request along with those approved with Case 05SN0136 include design and architectural elements that will be compatible with the surrounding community. REVITALIZATION Staff Contact: Carl Schlaudt(804-318-8674) schlaudtc@chesterfield.gov The project site is located in a revitalization area, consistent with the criteria-based approach of Road Cash Proffer Policy Section B.5 (as amended by the Board of Supervisors on April 26, 2017). The Revitalization Office supports development in revitalization areas that represents a substantial improvement above current area conditions. This proposal represents a substantial improvement above conditions of older residential development in the area generally bordered by Iron Bridge Road, Irongate Drive, and Beulah Road. Specifically, this project would be a substantial improvement in terms of: architectural variation, hardscaped driveways, exposed foundation treatment, foundation planting beds, front porch design, hardscaped front walkways, garage design, minimum house size, roof materials, siding materials, and yard trees. This project would be generally equivalent to surrounding development in terms of common recreational area (not provided), sidewalks (not provided), and street trees (not provided). The project would be generally less equivalent to surrounding development in terms of HVAC screening (not provided) and sodded front yards (not provided). The Revitalization Office supports the proposal as proffered. 817SN0746-2017MAY24-BOS-RPT COUNTY TRANSPORTATION Staff Contact: Jim Banks (804-748-1037) banksj@chesterfield.gov Case 05SN0136 establishes a maximum number of 80residential lots that can be developed (Proffered Condition 5). Based on those number of lots and trip generation rates for a single- family dwelling, the proposed development could generate approximately 855 average daily trips. The 43 recorded lots in the applicant’s current request could generate approximately 484 average daily trips.Traffic generated by development of the property will be initially distributed via residential streets to Irongate Drive and Beulah Road. Irongate Drive is a collector with a recommended right of way width of 70 feet, as identified on the County’s Thoroughfare Plan. Irongate Drive is a two-lane road. VDOT minimum geometric design standards recommend this road have 12-foot lane widths and 10 foot shoulders. In 2015, the traffic count on Irongate Drive south of Route 10 was 5,100 vehicles per day (Level of Service “D”). Beulah Road is identified on the County’s Thoroughfare Plan as a major arterial with a recommended right of way width of 90 feet. Beulah Road is a two-lane road. Sections of the road are substandard, with approximately 10-foot lane widths and no usable shoulders. VDOT minimum geometric design standards recommend this road have 12-foot lane widths and 10 foot shoulders. In 2015, the traffic count on Beulah Road between Kingsland Road and Salem Church Road was 7,350 vehicles per day (Level of Service “D”). Section 19.1-231 of the County Code outlines the general requirements to meet the needs of the traffic generated by a proposed development, including acceptable levels of service. This proposed residential development would contribute to an identifiable need for transportation improvements. The applicant has not offered to provide any mitigating road improvements. The property is located within Traffic Shed 9, which encompasses the area of the County bounded by I-95, Chippenham Parkway, Route 10, and Route 288. Some of the roads in this traffic shed or which serve this traffic shed are substandard, with little or no shoulders, fixed objects (trees) adjacent to the edge of the pavement, and poor vertical and horizontal alignments. The traffic volume generated from this proposed residential development will contribute to an identifiable need for transportation facility improvements to these roads in excess of existing transportation facility capacity. Roads in this shed or which serve this shed need to be improved or widened to address safety and accommodate increased traffic, including the increased traffic from the proposed development. An applicant may choose to address the development’s impact on the county’s road transportation network through dedication of property, construction of road improvements, or a cash proffer. If an applicant elects to offer cash to address the impact on the county’s road transportation network, Transportation staff has calculated the average impact of a single- family dwelling unit on the transportation network to be $12,652; however, the Board of Supervisors has adopted a policy establishing that it would accept a maximum cash proffer of $9,400 per dwelling unit as addressing the traffic impacts of residential development, with all of the funds to be dedicated towards improvements to the road network. As such, if the applicant chooses to address the development’s impacts on the county’s road network through payment 917SN0746-2017MAY24-BOS-RPT of a cash proffer, $9,400 per dwelling unit for improvements to the road network would be appropriate. According to the Office of Revitalization, the property is located within a revitalization area. Under the Road Cash Proffer Policy, no road cash proffer will be accepted for development in these areas. BUDGET & MANAGEMENT Staff Contact: Natalie Spillman (804-318-8767) spillmann@chesterfield.gov County finance staff is responsible for managing the finances of the County and making recommendations to the County Administrator regarding the allocation of available resources for the provision of services and capital facilities to serve the citizens of the County. Financestaff will advise the County Administrator if changed economic circumstances require adjustments to the County’s budget or capital improvement program. 1017SN0746-2017MAY24-BOS-RPT VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Brian Lokker (804-674-2384) brian.lokker@vdot.virginia.gov The proposed request will not impact these facilities. FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Mission The mission of Fire and Emergency Medical Services (EMS) is to protect life, property and the environment through a comprehensive fire and life safety program that ensures an adequate and timely response to emergencies. Response Times The proposed development is located in the urban response zone for which Fire & EMS has a goal of responding to at least 90% of the calls for service in under 7 minutes. Fire and EMS is currently unable to meet that goal. Nearby Fire/EMS Facilities The Dale Fire Station, Company Number 11 Anticipated Fire & EMS Impacts/Needs Based on an average of 0.2 calls per dwelling, it is estimated that this development will generate 9 annual calls for Fire/EMS services. Additional Fire and EMS Comments When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. 1117SN0746-2017MAY24-BOS-RPT SCHOOLS Staff Contact: Atonja Allen (804-318-8740) atonja_allen@ccpsnet.net Mission High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The comprehensive plansuggests a greater focus should be placed on linking schools with communities by providing greater access, flexible designs and locations that better meet the needs of the communities in which they are located. Capital Improvements The School Board FY2017 adopted Capital Improvement Plan (CIP) continues to support the 2013 voter approved school revitalization program that will replace or renovate ten schools and construct one new elementary school to add capacity in the Midlothian area of the county. The ten existing facilities that are part of the revitalization program are Providence Middle School, Monacan High School, Manchester Middle School, Beulah Elementary School, Enon Elementary School, Matoaca Elementary School, Harrowgate Elementary School, Reams Elementary School, Crestwood Elementary School, and Ettrick Elementary School. The project at Providence Middle School is currently in construction, a new Manchester Middle School is planned for construction on the existing school site,and the project at Monacan High School is complete. Additional information on the CIP can be found in the financial section of the CCPS Adopted Budget for FY2017. Anticipated School Impacts Enrollment Anticipated Schools Percent of Functional Number of Current Student Yield by Currently Total Capacity Trailers Enrollment School Type Serving Area Functional Capacity Elementary 9 Beulah 5468 623 114 Middle 5 Falling Creek125514 1189 95 High7 Meadowbrook 16264 1650 101 Total\[1\] 21 Note: Based upon average number of students per single family dwelling unit countywide at 0.48 students per unit. \[1\] Public Facilities Plan The Public Facilities Plan recommends that Beulah Elementary School berevitalized or replaced. In November 2016 the Board of Supervisors approved Case 17PD0147 for substantial accord to permit an elementary school located along Beulah Road north of Kingsland Road. Post 2020, the Plan also recommends revitalization or replacement of Falling Creek Middle School and a new high school facility in the vicinity of Chester Road and Route 288 north of Route 10, however at this time a budget has not been developed for the acquisition of land or construction of these school facilities as recommended in the Plan. 1217SN0746-2017MAY24-BOS-RPT LIBRARIES Staff Contact: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov Mission The public library system’s role in the county has expanded beyond its traditional function as a resource for information and materials, and now serves as a community gathering place for educational, cultural and informational services; community support during emergencies; economic development; and revitalization activities. Nearby Libraries Central Library Public Facilities Plan The Public Facilities Plan suggests the Central library should be expanded 6,000 square feet within existing facility. It is recommended that a new facility shall be constructed in the general vicinity of Kingsdale, Chester and Hopkins Roads. Land for expansion or replacement of this facility or new facility has not been acquired. PARKS AND RECREATION Staff Contact: Stuart Connock (804-751-4484) ConnockS@chesterfield.gov To date, no comments have been received. UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov The proposed request to reduce cash proffer will not impact the public water and wastewater systems. ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) WardR@chesterfield.gov Proffered Condition 10 of Case 05SN0136 was offered to address drainage impacts on adjacent properties, and will not be affected with this amendment. 1317SN0746-2017MAY24-BOS-RPT CASE HISTORY Applicant Submittals 12/8/16 Application submitted 1/30, 2/17, Revised proffered conditions were submitted 2/23, 2/27, 3/8/17 3/7/17 Revised application submitted to add recently recorded lots in Autumn Grove, Section B 3/29 & Revised proffered conditions submitted 4/3/17 Community Meeting 1/23/17Issues Discussed: Price and size of future homes Timetable for development of remaining homes and road improvements Speeding concerns along Koufax Drive Location of development within a Focused Investment & Redevelopment Area Quality elements to be proffered in the request by the applicant, including building materials and driveway treatments Planning Commission 3/21/17Action –DEFERRED TO APRIL 18, 2017 ON THEIR OWN MOTION WITH THE APPLICANT’S CONSENT 4/26/2017 Citizen Comments: No citizens spoke to this request. Recommendation – APPROVAL AND ACCEPTANCE OF THE PROFFERED CONDITION IN ATTACHMENT 1 Motion: Freye Second: Wallin AYES: Sloan, Jackson, Freye, Jones and Wallin The Board of Supervisors on Wednesday, May 24, 2017, beginning at 6:00 p.m., will consider this request. 1417SN0746-2017MAY24-BOS-RPT ATTACHMENT 1 PROFFERED CONDITION Note: Both the Planning Commission and Staff recommend acceptance of the following proffered condition, as offered by the applicant. With the approval of this request, Proffered Condition 2 of Case 05SN0136 shall be deleted. All other conditions of Case 05SN0136 shall remain in force and effect. The Applicant hereby offers the following proffer: 1.Architectural/Design Elements A.Driveways/Front Walks 1.Driveways: All private driveways servingresidential uses shall be brushed concrete, stamped concrete, exposed aggregate concrete or asphalt. 2.Front Walks: A minimum of a three (3) foot wide concrete front walk shall be provided to each dwelling unit to connect to drives, sidewalks or streets. B.Landscaping and Yards 1.Front Yard Tree: One (1) tree per lot shall be planted or retained. A tree shall be planted or retained on both street frontages on corner lots. The tree shall be planted or retained along the front property line within the street side half of the required front yard setback. The front yard tree shall be a large deciduous or evergreen tree and have a minimum caliper of 2.5 inches. Native trees shall be permitted to have a minimum caliper of 2 inches. 2.Front Foundation Planting Beds: Front foundation planting beds shall be required along the entire front facades of all units, and shall extend along all sides facing a street. Foundation Planting Beds shall be a minimum of 4’ wide from the unit foundation. Planting beds shall be defined with a trenched edge or suitable landscaping edging material. Planting beds shall include medium shrubs, spaced a maximum of four (4) feet apart. Unit corners shall be visually softened with vertical accent shrubs (4’-5’) or small evergreen trees (6’-8’) at the time of planting. C.Architecture and Materials 1.Style and Form:The architectural styles shall be interpretations of traditional Richmond architecture, using forms and elements compatible with those in the adjacent Autumn Grove Subdivision such as Georgian, Adam, Classical Revival Colonial, Greek revival, Queen Anne, and Craftsman Styles. 1517SN0746-2017MAY24-BOS-RPT 2.Repetition:Dwellings with the same elevations may not be located adjacent to or directly across from each other on the same street. This requirement does not apply to units on different streets backing up to each other. 3.Step-down Siding: Stepping the siding down below the first floor shall only be permitted in circumstances of unique topographical conditions. Step downs shall be permitted on the side and rear elevations only, with a maximum of two (2) steps permitted on any elevation, and with a minimum separation of eight (8) feet between steps. A minimum of 24 inches of exposed brick or stone shall be required, unless a lesser amount is approved by the Planning Department at time of plans review due to unique design circumstances. 4.Exterior Facades:Acceptable siding materials include brick, stone, masonry, stucco, synthetic stucco (E.I.F.S), and approved horizontal lap siding. Horizontal lap siding may be manufactured from natural wood or cement fiber board or may be premium quality vinyl siding. Plywood and metal siding are not permitted. Additional siding requirements: a.Where a dwelling borders more than one street, all street-facing facades shall be finished in the same materials. b.Premium quality vinyl is defined as vinyl siding with a minimum wall thickness of .042”. c.Synthetic Stucco (E.I.F.S) siding shall be finished in smooth, sand or level texture. Rough textures are not permitted. D.Roof Material: Roofing material shall be dimensional architectural shingles or better with a minimum 30-year warranty. E.Porches, Stoops and Decks 1.Front Porches: All front entry stoops and front porches shall be constructed with continuous masonry foundation wall or on 12” x 12” masonry piers. Extended front porches shall be a minimum of five (5) feet deep. Space between piers under porches shall be enclosed with framed lattice panels. Handrails and railings shall be finished painted wood, vinyl rails or metal rail systems with vertical pickets or swan balusters. Pickets shall be supported on top and bottom rails that span between columns. F.Garages: 1.Front loaded attached garages shall be permitted to extend as far forward from the front line of the main dwelling as the front line of the front porch provided that the rooflines of the porch and garage are contiguous. Where the rooflines are not contiguous, garages shall be permitted to project a maximum of two (2) feet forward of the front line of the main dwelling. 1617SN0746-2017MAY24-BOS-RPT 2.Front loaded and corner side loaded garages shall use an upgraded garage door. An upgraded garage door is any door with a minimum of two (2) enhanced features. Enhanced features shall include: windows, raised panels, decorative panels, arches, hingestraps or other architectural features on the exterior that enhance the entry (i.e. decorative lintels, shed roof overhangs, arches, columns, keystones, eyebrows, etc.). Flat panel garage doors are prohibited. (P) 1717SN0746-2017MAY24-BOS-RPT ATTACHMENT 2 APPROVED CONDITIONS (05SN0136) 1817SN0746-2017MAY24-BOS-RPT 1917SN0746-2017MAY24-BOS-RPT 2017SN0746-2017MAY24-BOS-RPT