Loading...
17SN0815 CASE NUMBER: 17SN0815 APPLICANT: Piney Branch Development Co. CHESTERFIELD COUNTY, VIRGINIA BERMUDADISTRICT STAFF’S ANALYSIS AND RECOMMENDATION Board of Supervisors Hearing: OCTOBER 25, 2017 Board of Supervisors Time Remaining: 365 DAYS Applicant’s Agent: ANDREW M. SCHERZER (804-794-0571) Planning Department Case Manager: RYAN RAMSEY(804-768-7592) 3.1 Acres – 12501 Chester Grove Drive REQUEST Amendment of zoning approval (Case 04SN0109) to amend cash proffers in a Residential (R-12) District. Specifically, the applicant proposes to amend Proffered Condition 2 relative to a cash proffer payment. Notes: A.The only condition that may be imposed is a buffer condition. The property owner may proffer conditions. B.Proffered conditions and approved zoning conditions are located in Attachments 1 and 2. SUMMARY A single-family residential subdivision (Chester Grove Subdivision) is under development. Existing zoning permits a maximum of twenty (20) dwelling units in this portion of the development, of which two (2) lots would be impacted by this request. The current cash proffer amount is $15,785 per dwelling unit. The current total potential value of the approved cash proffer equates to $31,750. The applicant has requested to reduce the cash proffer amount to $9,400 per dwelling unit, equating to total potential value of $18,800. Proffered conditions with this case provide design and architectural standards (summarized on pages 5 & 6) that are comparable in quality to that of the surrounding community or existing and planned area development. Providing a FIRST CHOICE community through excellence in public service RECOMMENDATIONS PLANNING APPROVAL COMMISSION PLANNING – APPROVAL The quality, design and architecture offered by the applicant in this case provide for a convenient, attractive and harmonious community STAFFcomparable in quality to that of the surrounding community. TRANSPORTATION – APPROVAL The development’s traffic impact will be addressed by providing cash payments. SUMMARY OF IDENTIFIED ISSUES DepartmentIssue The Public Facilities Plan recommends a new high school in the vicinity of Branders Bridge, Bradley Bridge and Ironbridge Roads, however at this SCHOOLS time a budget has not been developed for the acquisition of land or construction of this school facility as recommended in the Plan. 217SN0815-2017OCT25-BOS-RPT 317SN0815-2017OCT25-BOS-RPT Comprehensive Plan Classification: SUBURBAN RESIDENTIAL II The designation suggests the properties are appropriate for residential use of up to 2.0 to 4.0 dwellings per acre. Surrounding Land Uses and Development Chesterfield Community High School Carver Heights Drive Single-family Residential Uses Single-family Residential Uses (Chester Grove) Chester Grove Drive 417SN0815-2017OCT25-BOS-RPT PLANNING Staff Contact: Ryan Ramsey (804-768-7592) ramseyrp@chesterfield.gov Zoning History Case NumberRequest Rezone to R-12 containing a maximum of twenty (20) dwelling units. 04SN0109 ApprovedCash proffer of $9,000.00 per dwelling unit (currently escalated to $15,785). The (11/2003) staff report for this case analyzed the impact of the proposed development on public facilities and the applicant’s offer to mitigate that impact. Proposal Existing zoning permits a maximum of twenty (20)single family dwelling units. A total of two (2) lots in the Chester GroveSubdivisionwould be impacted by this request. Design Requirements of Case 04SN0109 Approval of this zoning request did not include conditions addressing community, dwelling or architectural design elements. Design High quality residential development addresses the Comprehensive Plan goals for strong and sustainable neighborhoods that are visually attractive, well-planned and well-maintained. Further, the purpose and intent of the zoning ordinance to promote the health, safety, convenience and general welfare of the public includes the creation of convenient, attractive and harmonious communities, protection against overcrowding of land, and protection of the natural environment. As such, developments that promote unique, viable and long lasting places and enhance the community are encouraged. The following provides an overview of additional design requirements offered as part of this request (Attachment 1 – Proffered Condition): Lot Design Hardscaped driveways required (except for Tax ID 781-651-9057, which would require the first 150 feet of driveway to be hardscaped, followed by a gravel treatment) Concrete front walks for each dwelling unit Landscaping, including a yard tree, and unit foundation plantings for dwellings Initial screening of HVAC/generators Architecture Building materials and architecture: Traditional Richmond architecture, compatible to Chester Grove o Specified building materials on exterior elevations of dwellings (i.e. minimum of o 0.042” thickness for vinyl siding) 517SN0815-2017OCT25-BOS-RPT 30-year architectural/dimensional roof shingles o Front porch treatments o Garage door treatments o As suggested by the Comprehensive Plan goals and the Zoning Ordinance, the proffered conditions of this request include quality design and architectural elements that are comparable in quality to that of the existing and planned area development. BUDGET & MANAGEMENT Staff Contact: Natalie Spillman (804-318-8767) spillmann@chesterfield.gov County finance staff is responsible for managing the finances of the County and making recommendations to the County Administrator regarding the allocation of available resources for the provision of services and capital facilities to serve the citizens of the County. Finance staff will advise the County Administrator if changed economic circumstances require adjustments to the County’s budget or capital improvement program. COUNTY TRANSPORTATION Staff Contact: Jim Banks (804-748-1037) banksj@chesterfield.gov The property could be developed for two (2) lots. Based on those numbers of lots and applying trip generation rates for a single-family dwelling, development could generate approximately 29 average daily trips. Traffic generated by development of the property will initially be distributed to Carver Heights Drive and Branders Bridge Road. Carver Heights Drive is a major arterial with a recommended right of way width of 90 feet, as identified on the County’s Thoroughfare Plan. Carver Heights Drive is a two-lane road. Sections of the road are substandard, with approximately 10-foot lane widths and no usable shoulders. VDOT minimum geometric design standards recommend this road have 12-foot lane widths and 10-foot shoulders. In 2015, the traffic count on Carver Heights Drive was 1,300 vehicles per day (Level of Service “C”). Branders Bridge Road is also identified on the County’s Thoroughfare Plan as a major arterial with a recommended right of way width of 90 feet. Branders Bridge Road is a two-lane road. Sections of the road are substandard, with approximately 10-foot lane widths and no usable shoulders. VDOT minimum geometric design standards recommend this road have 12-foot lane widths and 10-foot shoulders. In 2015, the traffic count on Branders Bridge Road was 8,935 vehicles per day (Level of Service “E”). Section 19.1-231 of the County Code outlines the general requirements to meet the needsof the traffic generated by a proposed development, including acceptable levels of service. This proposed residential development would contribute to an identifiable need for transportation improvements. The applicant has not offered to provide any mitigating road improvements. 617SN0815-2017OCT25-BOS-RPT The property is located within Traffic Shed 18, which encompasses the area of the county south of Route 10, east of Lewis Road, Bradley Bridge Road, and Sandy Ford Road, west of Harrowgate Road, and north of Hickory Road, Woodpecker Road, and Lakeview Avenue. Several roads in this traffic shed or which serve this traffic shed are substandard, with little or no shoulders, fixed objects (trees) adjacent to the edge of the pavement, and poor vertical and horizontal alignments. The traffic volume generated from this proposed residential development will contribute to an identifiable need for transportation facility improvements to these roads in excess of existing transportation facility capacity. Roads in this shed or which serve this shed need to be improved or widened to address safety and accommodate increased traffic, including the increased traffic from the proposed development. An applicant may choose to address the development’s impact on the county’s road transportation network through dedication of property, construction of road improvements, or a cash proffer. If an applicant elects to offer cash to address the impact on the county’s road transportation network, Transportation staff has calculated the average impact of a single- family dwelling unit on the transportation network to be $12,652; however, the Board of Supervisors has adopted a policy establishing that it would accept a maximum cash proffer of $9,400 per dwelling unit as addressing the traffic impacts of residential development, with all of the funds to be dedicated towards improvements to the road network. As such, if the applicant chooses to address the development’s impacts on the county’s road network through payment of a cash proffer, $9,400 per dwelling unit for improvements to the road network would be appropriate. The traffic impact of the proposed development could be valued at $18,800 (2 x $9,400). The applicant has proffered to pay $9,400 per dwelling unit (Proffered Condition 1). Staff supports the request. 717SN0815-2017OCT25-BOS-RPT FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Mission The mission of Fire and Emergency Medical Services (EMS) is to protect life, property and the environment through a comprehensive fire and life safety program that ensures an adequate and timely response to emergencies. Response Times The proposed development is located in the urban response zone for which Fire & EMS has a goal of responding to at least 90% of the calls for service in under seven (7) minutes. Fire and EMS is currently unable to meet that goal. Nearby Fire/EMS Facilities The Chester Fire Station, Company Number 1 Anticipated Fire & EMS Impacts/Needs Based on an average of 0.27 call per dwelling, it is estimated that this development will generate one (1) annual calls for Fire/EMS services. Additional Fire and EMS Comments When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. 817SN0815-2017OCT25-BOS-RPT SCHOOLS Staff Contact: Atonja Allen (804-318-8740) atonja_allen@ccpsnet.net Mission High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater access, flexible designs and locations that better meet the needs of the communities in which they are located. Capital Improvements The School Board FY2018 adopted Capital Improvement Plan (CIP) continues to support the 2013 voter approved school revitalization program that will replace or renovate ten schools and construct one new elementary school to add capacity in the Midlothian area of the county. The ten existing facilities that are part of the revitalization program are Providence Middle School, Monacan High School, Manchester Middle School, Beulah Elementary School, Enon Elementary School, Matoaca Elementary School, Harrowgate Elementary School, Reams Elementary School, Crestwood Elementary School, and Ettrick Elementary School. The project at Providence Middle School is currently in construction, a new Manchester Middle School is planned for construction onthe existing school site,and the project at Monacan High School is complete. Additional information on the CIP can be found in the financial section of the CCPS Adopted Budget for FY2018. Anticipated School Impacts ElementaryMiddleHigh Total (1) Anticipated Student Yield by 1 001 School Type Schools Currently Serving AreaEcoff Carver Bird Current Enrollment 767 991 1841 (2) Building Capacity 1000 1675 2500 2016-17 (3) Functional Capacity 841 1191 2291 School Year Enrollment Percent of Total 91%83%80% Data Functional Capacity Total Number of Trailers 2 35 Number of Classroom Trailers 1 15 Note: Based upon average number of students per single family dwelling unit countywide at 0.48 students per unit. (1) Building capacity is the number of standard classrooms times the average class size of 25 students. (2) Functional capacity considers special programs occurring in the standard classrooms at less than average class size (3) 917SN0815-2017OCT25-BOS-RPT Public Facilities Plan Post 2020, the Plan recommends a new high school in the vicinity of Branders Bridge, Bradley Bridge and Ironbridge Roads, however at this time a budget has not been developed for the acquisition of land or construction of this school facility as recommended in the Plan. LIBRARIES Staff Contact: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov Mission The public library system’s role in the county has expanded beyond its traditional function as a resource for information and materials, and now serves as a community gathering place for educational, cultural and informational services; community support during emergencies; economic development; and revitalization activities.The Public Facilities Plan, as part of the comprehensive plan, indicatesthe following library needs countywide: Nearby Library Chester Library PARKS AND RECREATION Staff Contact: Stuart Connock(804-751-4484) ConnockS@chesterfield.gov To date, no comments have been received. UTILITIES Staff Contact: Jamie Bland(751-4439) blandj@chesterfield.gov The proposed request to amend cash proffers will not impact the public water and wastewater systems. The applicant has proffered connection to water and sewer in Case 04SN0109. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Jonathan Phillippe(804-674-2560) jonathan.phillippe@vdot.virginia.gov ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) WardR@chesterfield.gov This request will not impact these facilities. 1017SN0815-2017OCT25-BOS-RPT CASE HISTORY Applicant Submittals 5/8/17 Application submitted Community Meeting 7/11/17Issues Discussed: Location of proposed homes Location of driveway entrances on Chester Grove Drive Planning Commission 9/19/17Citizen Comments: No citizens spoke to this request. Recommendation – APPROVAL SUBJECT TO THE PROFFERED CONDITIONS IN ATTACHMENT 1 Motion: Freye Second: Wallin AYES: Sloan, Jackson, Freye, Jones and Wallin The Board of Supervisors on Wednesday, October 25, 2017,beginning at 6:00 p.m., will consider this request. 1117SN0815-2017OCT25-BOS-RPT ATTACHMENT 1 PROFFERED CONDITIONS August 25, 2017 Note: The following proffered conditions are recommended by both the Planning Commission and Staff. With the approval of this request, Proffered Condition 2 of Case 04SN0109 shall be amended as outlined below. All other conditions of Case 04SN0109 shall remain in force and effect. 1.Cash Proffers. For each dwelling unit, the applicant, sub-divider, or assignee(s) shall pay $9,400 to the County of Chesterfield for road improvements within the service district for the property. Each payment shall be made prior to the issuance of a building permit for a dwelling unit unless state law modifies the timing of the payment. Should Chesterfield County impose impact fees at any time during the life of the development that are applicable to the property, the amount paid in cash proffers shall be in lieu of or credited toward, but not be in addition to, any impact fees, in a manner determined by the County. (B&M) The Applicant hereby offers the following conditions: 2.Architectural/Design Elements: a.Driveways/Front Walks i.Driveways: All portions of driveways and parking areas shall be brushed concrete, stamped concrete, exposed aggregate concrete, asphalt, or decorative pavers, provided that the private driveway for Tax ID 781-651- 9057 shall be paved, with any of the aforementioned materials, for the first 150 feet, starting at Chester Grove Drive, and gravel shall be permitted for the remaining driveway leading to the house. ii.Front Walks:A minimum of a 42-inch-wide concrete front walk shall be provided to the front entrance of each dwelling unit, to connect to drives, sidewalks or street. b.Landscaping i.Front Yard Tree: One (1) tree per lot shall be planted or retained. A tree shall be planted or retained on both street frontages on corner lots. The front yard tree shall be a large deciduous tree and have a minimum caliper of 2.5 inches. Native trees shall be permitted to have a minimum caliper of 2 inches. ii.Front Foundation Planting Beds: Foundation planting is required along the entire front façade of all units, and shall extend along all sides facing a street. Foundation Planting Beds shall be a minimum of four (4) feet wide from the unit foundation. Planting beds shall be defined with a 1217SN0815-2017OCT25-BOS-RPT trenched edge or suitable landscape edging material. Planting beds shall include medium shrubs and may include spreading groundcovers. Unit corners shall be visually softened with vertical accent shrubs (4’-5’) or small evergreen trees (6’-8’) at the time of planting. c.Architecture and Materials i.Style and Form: The architectural styles shall be interpretations of traditional Richmond architecture, using forms and elements compatible with those in the Chester Grove subdivision such as Georgian, Adam, Classical Revival Colonial, Greek Revival, Queen Anne, and Craftsman Styles. ii.Foundations. All exposed portions of the foundation of each dwelling unit shall be faced with brick. iii.Step-down Siding: Stepping the siding down below the first floor shall only be permitted in circumstances of unique topographical conditions. Step downs shall be permitted on the side and rear elevations only, with a maximum of two (2) steps permitted on any elevation, and with a minimum separation of eight (8) feet between steps. A minimum of 24 inches of exposed brick or stone shall be required, unless a lesser amount is approved by the Planning Department at time of plans review due to unique design circumstances. iv.Exterior Facades:Acceptable siding materials include brick, stone, masonry, vinyl siding, and approved horizontal lap siding. Horizontal lap siding may be manufactured from natural wood or cement fiber board or may be quality vinyl siding with a minimum wall thickness of 0.042 inches. Plywood and metal siding are not permitted. d.Roof Details. i.Roofing material shall be dimensional architectural shingles or better with a minimum 30-year warranty. ii.All constructed units shall have a minimum twelve (12) inch eave in front and rear. e.Porches and Stoops i.Front Porches: All front entry stoops and front porches shall be constructed with continuous masonry foundation wall or on 12” x 12” masonry piers. Extended front porches shall be a minimum of five (5) feet deep. Space between piers under porches shall be enclosed with framed lattice panels. Handrails and railings shall be finished painted wood, vinyl rails or metal rail systems with vertical pickets or swan balusters. Pickets shall be supported on top and bottom rails that span between columns. 1317SN0815-2017OCT25-BOS-RPT f.Garages. i.Front loaded attached garages shall be permitted to extend as far forward from the front line of the main dwelling as the front line of the front porch provided that the rooflines of the porch and garage are contiguous. Where the rooflines are not contiguous, garages shall be permitted to project a maximum of four (4) feet forward of the front line of the main dwelling. ii.Front loaded and corner side loaded garages shall use an upgraded garage door. An upgraded garage door is any door with a minimum of two (2) enhanced features. Enhanced features shall include windows, raised panels, decorative panels, arches, hinge straps or other architectural features on the exterior that enhance the entry (i.e. decorative lintels, shed roof overhangs, arches, columns, keystones, eyebrows, etc.) Flat panel garage doors are prohibited. g.Heating, Ventilation and Air Conditioning (HVAC) Units and Whole House Generators.Units shall initially be screened from view of public roads by landscaping or low maintenance material, as approved by the Planning Department. (P & BI) 1417SN0815-2017OCT25-BOS-RPT ATTACHMENT 2 APPROVED CONDITIONS (04SN0109) 1517SN0815-2017OCT25-BOS-RPT 1617SN0815-2017OCT25-BOS-RPT