Loading...
17SN0828 CASE NUMBER: 17SN0828 APPLICANT: P&B Development LLC CHESTERFIELD COUNTY, VIRGINIA BERMUDA DISTRICT AND RECOMMENDATION Board of Supervisors Hearing: OCTOBER 25, 2017 Board of Supervisors Time Remaining: 365 DAYS ANDREW SCHERZER (804-794-0571) DON BALZER (804-897-0143) 21.3 Acres 16601 Branders Bridge Road Planning Department Case Manager: DREW NOXON (804-796-7122) REQUEST Rezoning from Agricultural (A) to Residential (R-12). Notes: A.The only condition that may be imposed is a buffer condition. The property owner may proffer conditions B.Proffered conditions are located in Attachment 1. SUMMARY A single-family residential subdivision with a minimum lot size of 12,000 square feet is planned. The development will be an expansion of the Harrowgate Meadows subdivision. Proffered conditions limit development density to a maximum of two (2) dwelling units per acre, yielding 42 units. Proffered conditions provide design and architectural standards (summarized on page 6) that are elevated in quality to that of the surrounding community. RECOMMENDATIONS APPROVAL PLANNING COMMISSION PLANNING APPROVAL Complies with Comprehensive Plan Quality, design and architecture offered by the applicant provide for a convenient, attractive and harmonious community elevated in quality STAFF to that of the surrounding community. TRANSPORTATION APPROVAL payments. Providing a FIRST CHOICE community through excellence in public service SUMMARY OF IDENTIFIED ISSUES Department Issue The tǒĬƌźĭ CğĭźƌźƷźĻƭ tƌğƓ recommends a new elementary school in the vicinity of Ruffin Mill Road, Enon Church Road and Ramblewood Drive, a SCHOOLS new middle school in the vicinity of Chester and West Hundred Roads, and a new high school in the vicinity of Branders Bridge, Bradley Bridge, and Iron Bridge Roads north of Swift Creek. Land for these facilities has/has not been acquired. The tǒĬƌźĭ CğĭźƌźƷźĻƭ tƌğƓ recommends that the Ettrick-Matoaca library LIBRARIES should be expanded/replaced or a new facility shall be constructed in the general vicinity at or near current site. Land for expansion or replacement of this facility has not been acquired. 217SN0828-2017OCT25-BOS-RPT 317SN0828-2017OCT25-BOS-RPT Comprehensive Plan Classification: SUBURBAN RESIDENTIAL II The designation suggests the property is appropriate for residential development at a maximum of 2.0 to 4.0 dwellings per acre. Surrounding Land Uses and Development Parkgate Drive Harrowgate Harrowgate Meadows Park Meadows Cougar Subdivision Trail Harrowgate Place subdivision Single-family residential uses and vacant agricultural land Branders Bridge Road 417SN0828-2017OCT25-BOS-RPT PLANNING Staff Contact: Andrew Noxon (804-796-7122) noxona@chesterfield.gov Sole Access Planned Through Adjacent Subdivisions The Comprehensive Plan suggests as new development proposals come forward, densities, average lot sizes, house sizes and quality of existing residential neighborhoods should be closely considered when new development borders, and primary access is through these existing residential neighborhoods by way of adjacent public subdivision roads. This development would have sole access through the exiting adjacent neighborhoods; therefore, consideration should be given to densities, average lot sizes, house sizes and quality of existing residential neighborhoods. Development of the property is planned with access from Parkgate Drive, which currently serves the Harrowgate Meadows Subdivision. The chart below provides a comparison of density, minimum and average lots sizes, and house sizes among these adjacent subdivisions and the proposed development. Comparison of Adjacent Developments Harrowgate Meadows Windsor Hills Proposed (Zoned R-12) (Zoned R-7) Development 2.0 dwellings per acre (maximum of 42 Density 1.7 dwellings per acre 3.75 dwellings per acre lots) tƩƚŅŅĻƩĻķ /ƚƓķźƷźƚƓ Њ͵ Minimum Lot Size 12,000 square feet 7,000 square feet 12,000 square feet 14,727 square feet* 14,460 square feet Average Lot Size Range = 12,117 - Range = 6,758 - Not provided 22,884 33,144 House Size (sq. ft. 1,500 minimum 1,400 2,500 1,400 2,500 gfa) tƩƚŅŅĻƩĻķ /ƚƓķźƷźƚƓ Ќ * Within Harrowgate Meadows, approximately 36 percent (31 acres) are impacted by wetlands, resulting in a wide range of lot sizes. A more appropriate comparison of average lot size would be lots along the proposed access, Parkgate Drive, that are not encumbered by wetlands. For this purpose, lots 31 - 40, and 18 (Section 1) and Lots 7 - 12, and 7, 21-20 (Section 2) were used. Of the twenty-three (23) lots evaluated, ten (10) contain approximately 12,000 square feet in area. The maximum density of the proposed subdivision (2.0 dwellings per acre) is within the density suggested by the Comprehensive Plan, and is consistent with the average density of Harrowgate Meadows (Sections 1 and 2) and Windsor Hills (approximately 2.0 dwellings per acre). Minimum house sizes proffered in this case are within the existing range of these adjacent developments. While an average lot size has not been provided as part of this case, staff believes that the density and minimum lot sizes will offer assurance these three developments will be compatible. 517SN0828-2017OCT25-BOS-RPT Design High quality residential development addresses the Comprehensive Plan goals for strong and sustainable neighborhoods that are visually attractive, well-planned and well-maintained. Further, the purpose and intent of the zoning ordinance to promote the health, safety, convenience and general welfare of the public includes the creation of convenient, attractive and harmonious communities, protection against overcrowding of land, and protection of the natural environment. As such, developments that promote unique, viable and long-lasting places and enhance the community are encouraged. The following provides an overview of the design requirements offered as part of this request (Attachment 1 Proffered Conditions): Lot Design Paved driveways and front walkways o Front foundation planting beds o One street tree per lot o Screening of mechanical units o Dwelling Design Traditional Richmond architectural style o Minimum dwelling size (gfa) of 1,500 sq. ft. o All dwellings to have brick, stone, masonry, EIFS, stucco or horizontal siding, to o include premium quality vinyl siding with minimum thickness of .042 inches Foundations of brick or stone veneer o Step down siding permitted based on unique topography with limited step down and o maintaining 24 inches of exposed foundation 30-year architectural/dimensional roof shingles o All street-facing facades finished in same materials o Dwellings adjacent to or directly across the street have different elevations o Maximum projection for front-loaded garages from front facade; upgraded garage o door treatments for front and corner-side loaded garages Front porch/stoop treatment o As suggested by the Comprehensive Plan goals and the Zoning Ordinance, the proffered conditions of this request include quality design and architectural elements that are elevated in quality to that of the surrounding community. 617SN0828-2017OCT25-BOS-RPT BUDGET & MANAGEMENT Staff Contact: Natalie Spillman (804-318-8767) spillmann@chesterfield.gov County finance staff is responsible for managing the finances of the County and making recommendations to the County Administrator regarding the allocation of available resources for the provision of services and capital facilities to serve the citizens of the County. Finance staff will advise the County Administrator if changed economic circumstances require . COUNTY TRANSPORTATION Staff Contact: Jim Banks (804-748-1037) banksj@chesterfield.gov The property could be developed for 42 lots. Based on those numbers of lots and applying trip generation rates for a single-family dwelling, development could generate approximately 473 average daily trips. Traffic generated by development of the property will initially be distributed via Cougar Trail to Harrowgate Road. Harrowgate Road is a major arterial with a recommended right of way width of 120 feet, as id-lane road. In 2015, the Section 19.1-231 of the County Code outlines the general requirements to meet the needs of the traffic generated by a proposed development, including acceptable levels of service. This proposed residential development would contribute to an identifiable need for transportation improvements. The applicant has not offered to provide any mitigating road improvements. The property is located within Traffic Shed 18, which encompasses the area of the county south of Route 10, east of Lewis Road, Bradley Bridge Road, and Sandy Ford Road, west of Harrowgate Road, and north of Hickory Road, Woodpecker Road, and Lakeview Avenue. Several roads in this traffic shed or which serve this traffic shed are substandard, with little or no shoulders, fixed objects (trees) adjacent to the edge of the pavement, and poor vertical and horizontal alignments. The traffic volume generated from this proposed residential development will contribute to an identifiable need for transportation facility improvements to these roads in excess of existing transportation facility capacity. Roads in this shed or which serve this shed need to be improved or widened to address safety and accommodate increased traffic, including the increased traffic from the proposed development. transportation network through dedication of property, construction of road improvements, or transportation network, Transportation staff has calculated the average impact of a single- family dwelling unit on the transportation network to be $12,652; however, the Board of Supervisors has adopted a policy establishing that it would accept a maximum cash proffer of $9,400 per dwelling unit as addressing the traffic impacts of residential development, with all of the funds to be dedicated towards improvements to the road network. As such, if the applicant 717SN0828-2017OCT25-BOS-RPT of a cash proffer, $9,400 per dwelling unit for improvements to the road network would be appropriate. The traffic impact of the proposed development could be valued at $394,800 (42 x $9,400). The applicant has proffered to pay $9,400 for each dwelling unit (Proffered Condition 2). Staff supports the request. FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Mission The mission of Fire and Emergency Medical Services (EMS) is to protect life, property and the environment through a comprehensive fire and life safety program that ensures an adequate and timely response to emergencies. Response Times The proposed development is located in the urban response zone for which Fire & EMS has a goal of responding to at least 90% of the calls for service in under twelve (12) minutes. Fire and EMS is currently unable to meet that goal. Nearby Fire/EMS Facilities The Harrowgate Fire Station, Company Number 21 The Bensley-Bermuda Fire Volunteer Rescue Squad Anticipated Fire & EMS Impacts/Needs Based on an average of 0.29204 calls per dwelling, it is estimated that this development will generate 12 annual calls for Fire/EMS services. Additional Fire and EMS Comments When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. 817SN0828-2017OCT25-BOS-RPT SCHOOLS Staff Contact: Atonja Allen (804-318-8740) atonja_allen@ccpsnet.net Mission High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater access, flexible designs and locations that better meet the needs of the communities in which they are located. Capital Improvements The School Board FY2018 adopted Capital Improvement Plan (CIP) continues to support the 2013 voter approved school revitalization program that will replace or renovate ten schools and construct one new elementary school to add capacity in the Midlothian area of the county. The ten existing facilities that are part of the revitalization program are Providence Middle School, Monacan High School, Manchester Middle School, Beulah Elementary School, Enon Elementary School, Matoaca Elementary School, Harrowgate Elementary School, Reams Elementary School, Crestwood Elementary School, and Ettrick Elementary School. The project at Providence Middle School is currently in construction, a new Manchester Middle School is planned for construction on the existing school site, and the project at Monacan High School is complete. Additional information on the CIP can be found in the financial section of the CCPS Adopted Budget for FY2018. Anticipated School Impacts Elementary Middle High Total (1) Anticipated Student Yield by 9 5 7 21 School Type Schools Currently Serving Area Harrowgate Carver Matoaca Current Enrollment 607 991 1756 Building Capacity (2) 800 1675 1975 2016-17 (3) Functional Capacity 648 1191 1913 School Year Enrollment Percent of Total 94% 83% 92% Data Functional Capacity Total Number of Trailers 7 3 5 Number of Classroom Trailers 6 1 5 Note: Based upon average number of students per single family dwelling unit countywide at 0.48 students per unit. (1) Building capacity is the number of standard classrooms times the average class size of 25 students. (2) Functional capacity considers special programs occurring in the standard classrooms at less than average class size (3) Public Facilities Plan Post 2020, the tƌğƓ recommends a new elementary school in the vicinity of Ruffin Mill Road, Enon Church Road and Ramblewood Drive, a new middle school in the vicinity of Chester and West Hundred Roads, and a new high school in the vicinity of Branders Bridge, Bradley Bridge, and Iron Bridge Roads north of Swift Creek, however at this time a budget has not been developed for the acquisition of land or construction of these school facilities as recommended in the tƌğƓ. 917SN0828-2017OCT25-BOS-RPT LIBRARIES Staff Contact: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov Mission resource for information and materials, and now serves as a community gathering place for educational, cultural and informational services; community support during emergencies; economic development; and revitalization activities. The tǒĬƌźĭ CğĭźƌźƷźĻƭ tƌğƓ, as part of the comprehensive plan, indicates that five libraries and one community arts center should be constructed countywide. Nearby Libraries Ettrick-Matoaca Chester Public Facilities Plan The Public Facilities Plan suggests the Ettrick-Matoaca library should be expanded/replaced or a new facility shall be constructed in the general vicinity at or near current site. Land for expansion or replacement of this facility has not been acquired. PARKS AND RECREATION Staff Contact: Stuart Connock (804-751-4484) ConnockS@chesterfield.gov Mission The County supports a high-quality park system to provide residents and visitors with equitable access to active and passive recreation opportunities. The 2012 level of service is 5.9 acres of regional, community and neighborhood parkland per 1,000 persons whereas the target level of service is 9 acres per 1,000 persons. Staff has not received comments to date. UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov The proposed development is located within the mandatory water/sewer connection area. The applicant has indicated they will connect to the public water and sewer systems. (Proffered Condition 2) All water and sewer design and construction must comply with the current revision of the Cheste Provisions need to be applied for the future potential water and sewer service to adjacent parcels, which may include public water and sewer easements. 1017SN0828-2017OCT25-BOS-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) WardR@chesterfield.gov Geography The subject property drains south and southeast to an unnamed tributary to Timsbury Creek, then to Swift Creek. The entire property is located within the Lower Swift Creek Watershed. Environmental Features A Resource Protection Area Designation (RPAD) has been submitted to the Department of Environmental Engineering-Water Quality Section for the subject property and is currently under review. The RPAD must be approved by the Department of Environmental Engineering- Water Quality Section prior to construction plan approval. Wetlands shall not be impacted without approval from the U.S. Army Corps of Engineers and/or the Virginia Department of Environmental Quality. Stormwater Management The development of the subject property will be subject to the Part IIB technical criteria of the VSMP Regulations for water quality and quantity. Any areas of forest/open space used for stormwater quality compliance should be outside the limits of the residential lots. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Jonathan Phillippe (804-674-2560) jonathan.phillippe@vdot.virginia.gov This request will not impact these facilities. 1117SN0828-2017OCT25-BOS-RPT CASE HISTORY Applicant Submittals 6/1/17 Application submitted 6/21/17, Proffered conditions submitted 8/25/17 & 8/30/17 Community Meeting 7/16/17 Issues Discussed: Garage door treatment on side-loaded garages Roadway connection to Branders Bridge Road Cash proffer payments for schools and other facilities Protection of wetlands, stormwater discharge Planning Commission 9/19/17 Citizen Comments: One citizen spoke in opposition, noting concerns relative to privacy and safety, reduction in property values, displacement of wildlife, and limited capacity of nearby schools. If development is approved, a tree preservation area adjoining neighboring properties is desired. Commission Discussion: Mr. Sloan stated that a community meeting had been held and the applicant has worked extensively to minimize impacts on adjoining properties. In addition, environmental features will provide adequate separation to adjoining neighbors. He encouraged the citizen who spoke in opposition to meet with the applicant to review conceptual layout of subdivision. Recommendation APPROVAL SUBJECT TO THE PROFFERED CONDITIONS IN ATTACHMENT 1 Motion: Sloan Second: Jackson AYES: Sloan, Jackson, Freye, Jones and Wallin The Board of Supervisors on Wednesday, October 25, 2017, beginning at 6:00 p.m., will consider this request. 1217SN0828-2017OCT25-BOS-RPT ATTACHMENT 1 PROFFERED CONDITIONS (August 30, 2017) Note: The following proffered conditions are recommended by both the Planning Commission and Staff. 1.Density. The maximum density of this development shall not exceed two (2) dwelling units per acre. (P) 2.Utilities. Public water and wastewater systems shall be used. (U) 3.Dwelling Size. The minimum gross floor area of each dwelling unit shall be 1,500 square feet. (P) 4.Road Cash Proffers. a.The applicant, sub-divider, or assignee(s) shall pay $9,400 for each dwelling unit to the County of Chesterfield for road improvements within the service district for the property. b.Each payment shall be made prior to the issuance of a building permit for a dwelling unit unless state law modifies the timing of the payment. Should Chesterfield County impose impact fees at any time during the life of the development that are applicable to the property, the amount paid in cash proffers shall be in lieu of or credited toward, but not in addition to, any impact fees, in a manner determined by the County. c.At the option of the Transportation Department, cash proffer payments may be reduced for the cost of transportation improvements provided by the applicant, sub-divider, or assignee(s), as determined by the Transportation Department. (B&M) 5.Architectural/Design Elements A.Driveways/Front Walks 1.Driveways: All private driveways serving residential uses shall be brushed concrete, stamped concrete, exposed aggregate concrete or asphalt. 2.Front Walks: A minimum of a three (3) foot wide concrete front walk shall be provided to each dwelling unit to connect to drives, sidewalks or streets. B.Landscaping and Yards 1.Front Yard Tree: One (1) tree per lot shall be planted or retained, as approved by the Planning Department at time of plans review. A tree shall be planted or retained on both street frontages on corner lots. The tree shall be 1317SN0828-2017OCT25-BOS-RPT planted or retained along the front property line within the street side half of the required front yard setback. The front yard tree shall be a large deciduous or evergreen tree and have a minimum caliper of 2.5 inches. Native trees shall be permitted to have a minimum caliper of 2 inches. 2.Front Foundation Planting Beds: Front foundation planting beds shall be required along the entire front facades of all units, and shall extend along all from the unit foundation. Planting beds shall be defined with a trenched edge or suitable landscaping edging material. Planting beds shall include medium shrubs, spaced a maximum of four (4) feet apart. Unit corners shall - - C.Architecture and Materials 1.Style and Form: The architectural styles shall be interpretations of traditional Richmond architecture, using forms and elements compatible with styles such as Georgian, Adam, Classical Revival Colonial, Greek revival, Queen Anne, and Craftsman Styles. 2.Repetition: Dwellings with the same elevations may not be located adjacent to or directly across from each other on the same street. This requirement does not apply to units on different streets backing up to each other. 3.Foundations. All exposed portions of the foundation of each dwelling unit shall be faced with brick or stone veneer. 4.Step-down Siding: Stepping the siding down below the first floor shall only be permitted in circumstances of unique topographical conditions. Step downs shall be permitted on the side and rear elevations only, with a maximum of two (2) steps permitted on any elevation, and with a minimum separation of eight (8) feet between steps. A minimum of 24 inches of exposed brick or stone shall be required, unless a lesser amount is approved by the Planning Department at time of plans review due to unique design circumstances. 5.Exterior Facades: Acceptable siding materials include brick, stone, masonry, stucco, synthetic stucco (E.I.F.S), and approved horizontal lap siding. Horizontal lap siding may be manufactured from natural wood or cement fiber board or may be premium quality vinyl siding. Plywood and metal siding are not permitted. Additional siding requirements: a.Where a dwelling borders more than one street, all street-facing facades shall be finished in the same materials. b.Premium quality vinyl is defined as vinyl siding with a minimum wall thickness of 0.042 inches. 1417SN0828-2017OCT25-BOS-RPT c.Synthetic Stucco (E.I.F.S) siding shall be finished in smooth, sand or level texture. Rough textures are not permitted. D.Roof Material: Roofing material shall be dimensional architectural shingles or better with a minimum 30-year warranty. E.Porches and Stoops. 1.Front Porches: All front entry stoops and front porches shall be constructed with co Extended front porches shall be a minimum of five (5) feet deep. Space between piers under porches shall be enclosed with framed lattice panels. Handrails and railings shall be finished painted wood, vinyl rails or metal rail systems with vertical pickets or swan balusters. Pickets shall be supported on top and bottom rails that span between columns. F.Garages: 1.Front loaded attached garages shall be permitted to extend as far forward from the front line of the main dwelling as the front line of the front porch provided that the rooflines of the porch and garage are contiguous. Where the rooflines are not contiguous, garages shall be permitted to project a maximum of two (2) feet forward of the front line of the main dwelling. 2.Front loaded and corner side loaded garages shall use an upgraded garage door. An upgraded garage door is any door with a minimum of two (2) enhanced features. Enhanced features shall include: windows, raised panels, decorative panels, arches, hinge straps or other architectural features on the exterior that enhance the entry (i.e. decorative lintels, shed roof overhangs, arches, columns, keystones, eyebrows, etc.). Flat panel garage doors are prohibited. G.Heating, Ventilation and Air Conditioning (HVAC) Units and Whole House Generators. Units shall initially be screened from view of public roads by landscaping or low maintenance material, as approved by the Planning Department. (P) 1517SN0828-2017OCT25-BOS-RPT