Loading...
17SN0825 CASE NUMBER: 17SN0825 APPLICANT: Hanky, LLC CHESTERFIELD COUNTY, VIRGINIA BERMUDADISTRICT STAFF’S ANALYSIS AND RECOMMENDATION Board of Supervisors Hearing: NOVEMBER 15, 2017 Board of Supervisors Time Remaining: 365 DAYS Applicant’s Agent: DAN CASKIE (804-569-7060) Applicant’s Contact: MICHAEL HANKY(804-569-7060) 22.7 Acres – 13620 Bermuda Orchard Lane Planning Department Case Manager: RYAN RAMSEY (804-768-7592) REQUEST Rezoning from Agricultural (A) to Residential (R-12). Notes: A.The only condition that may be imposed is a buffer condition. The property owner may proffer conditions. B.Proffered conditions and an exhibit are located in Attachments 1- 2. SUMMARY A single-family residential subdivision with a minimum lot size of 12,000 square feetis proposed. Density for the development would be limited to a maximum of fifty-five (55) lots. Proffered conditions provide design and architectural standards (summarized on pages5 and 6) that are comparable in quality to that of existing and planned area development. RECOMMENDATIONS APPROVAL PLANNING COMMISSION PLANNING – APPROVAL Quality, design and architecture offered by the applicant provide for a convenient, attractive and harmonious community comparable in STAFF quality to that of the surrounding community. TRANSPORTATION – APPROVAL The development’s traffic impact will be addressed by providing cash payments. Providing a FIRST CHOICE community through excellence in public service SUMMARY OF IDENTIFIED ISSUES DepartmentIssue The Public Facilities Plan recommends a new elementary school in the vicinity of Ruffin Mill Road, Enon Church Road and Ramblewood Drive, a new middle school in the vicinity of Chester and West Hundred Roads, and SCHOOLS a new high school in the vicinity of Branders Bridge, Bradley Bridge, and Iron Bridge Roadsnorth of Swift Creek. At this time a budget has not been developed for the acquisition of land or construction of these school facilities as recommended in the Plan. The Public Facilities Plan recommends that the Enon Library should be expanded/replaced or a new facility shall be constructed in the general LIBRARIES vicinity at or near current site. Land for expansion or replacement of this facility or new facility has not been acquired. 217SN0825-2017NOV15-CPC-RPT 317SN0825-2017NOV15-CPC-RPT Comprehensive Plan Classification: SUBURBAN RESIDENTIAL II The designation suggests the property is appropriate for residential development at a maximum density of 2.0 to 4.0 dwellings per acre. Surrounding Land Uses and Development Bermuda Orchard Lane Bermuda Orchard Enon Oaks Enon Oaks Lane 417SN0825-2017NOV15-CPC-RPT PLANNING Staff Contact: Ryan Ramsey (804-768-7592) ramseyrp@chesterfield.gov Proposal A single family residential subdivisioncontaining a maximum of fifty-five (55) dwelling units is planned. Each lot within this development would, at a minimum,comply with R-12 development standards. Design High quality residential development addressesthe Comprehensive Plan goals for strong and sustainable neighborhoods that are visually attractive, well-planned and well-maintained. Further, the purpose and intent of the zoning ordinance to promote the health, safety, convenience and general welfare of the public includes the creation of convenient, attractive and harmoniouscommunities, protection against overcrowding of land, and protection of the natural environment. As such, developments that promote unique, viable and long lasting places and enhance the community are encouraged. The following provides an overview of design requirements offered as part of this request (Attachment 1 – Proffered Conditions 1 -4): Community Design Density limited to fifty-five (55) lots Landscaping and Yards Sodded and irrigated front and street side corner yards o Foundation planting beds along all dwelling facades facing a street o Two (2) supplemental yard trees to be planted or retained in front yard of each o dwelling A 20-foot buffer to be maintained along rear lot lines of those lots adjoiningEnon o Oaks Subdivision, as well as those lots with rear property lines along the northern property boundary (Exhibit A, Attachment 2) Lot Design Hardscaped driveways and front walkways House Design Minimum dwelling size (gross floor area) of 1,400 square feet (ranch/1-story) and 1,600 square feet (2-stories) All dwellings to have brick, stone EIFIS, stucco or horizontal siding, to include quality vinyl siding with minimum thickness of .044 inches Foundations of brick, stone or a combination of both. If facades are constructed entirely of stucco, then synthetic or natural stucco foundations may be permitted Varied roof designs and roof materials to be dimensional architectural shingles with minimum 30-year warranty Front porch, stoop, and chimney treatments Permitted projections limited for front-loaded garages, garage door treatments 517SN0825-2017NOV15-CPC-RPT Variation in front elevation treatments Initial screening of HVAC/whole house generators from public roads with landscaping or low maintenance material As suggested by the Comprehensive Plan goals and the Zoning Ordinance, the proffered conditions of this request include quality design and architectural elements that are comparablein quality to that of the surrounding community. BUDGET & MANAGEMENT Staff Contact: Natalie Spillman (804-318-8767) spillmann@chesterfield.gov County finance staff is responsible for managing the finances of the County and making recommendations to the County Administrator regarding the allocation of available resources for the provision of services and capital facilities to serve the citizens of the County. Finance staff will advise the County Administrator if changed economic circumstances require adjustments to the County’s budget or capital improvement program. COUNTY TRANSPORTATION Staff Contact: Jim Banks (804-748-1037) banksj@chesterfield.gov A proffered condition would limit development to a maximum of 55 dwelling units (Proffered Condition 13). Based on that number of lots and applying trip generation rates for a single- family dwelling, development could generate approximately 606 average daily trips. Traffic generated by development of the property will be initially distributed to via Bermuda Orchard Lane to East Hundred Road (Route 10). Bermuda Orchard Lane is a collector with a recommended right of way width of 70 feet, as identified on the County’s Thoroughfare Plan. Bermuda Orchard Lane is a two-lane road. In 2015, the traffic count on Bermuda Orchard Lane was 2,050 vehicles per day (Level of Service “C”). Route 10 is identified on the County’s Thoroughfare Plan.as a major arterial with a recommended right of way width of 120 to 200 feet. Route 10 is a six-lane divided road. In 2015, the traffic count on Route 10 west of Interstate 295 was 41,080 vehicles per day (Level of Service “C”). Section 19.1-231 of the County Code outlines the general requirements to meet the needs of the traffic generated by a proposed development, including acceptable levels of service. This proposed residential development would contribute to an identifiable need for transportation improvements. The applicant has offered the following: Dedication. (Proffered Condition 11) 35 feet of right-of-way along Bermuda Orchard Lane for the property frontage. 617SN0825-2017NOV15-CPC-RPT Vehicular Access. (Proffered Condition 12) One public road to Bermuda Orchard Lane. Road Improvements. (Proffered Condition 13) Left and right turn lanes along Bermuda Orchard Laneat theapproved access. Sidewalk along Bermuda Orchard Lane for the property frontage. The property is within Traffic Shed 15, which encompasses a large area in the eastern part of the County, east of I-95. Many roads in this part of the county have little or no shoulders, fixed objects (trees) adjacent to the edge of the pavement and poor vertical and horizontal alignments. The traffic volume generated from this proposed residential development will contribute to an identifiable need for transportation facility improvements to these roads in excess of existing transportation facility capacity. Roads in this shed or which serve this shed need to be improved or widened to address safety and accommodate increased traffic, including the increased traffic from the proposed development. An applicant may choose to address the development’s impact on the county’s road transportation network through dedication of property, construction of road improvements, or a cash proffer. If an applicant elects to offer cash to address the impact on the county’s road transportation network, Transportation staff has calculated the average impact of a single- family dwelling unit on the transportation network to be $12,652; however, the Board of Supervisors has adopted a policy establishing that it would accept a maximum cash proffer of $9,400 per dwelling unit as addressing the traffic impacts of residential development, with all of the funds to be dedicated towards improvements to the road network. As such, if the applicant chooses to address the development’s impacts on the county’s road network through payment of a cash proffer, $9,400 per dwelling unit for improvements to the road network would be appropriate. The traffic impact of the proposed development could be valued at $517,000 (55 x $9,400). The applicant has proffered to pay $9,400 for each dwelling unit (Proffered Condition 7). Staff supports the request. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Jonathan Phillippe(804-674-2560) jonathan.phillippe@vdot.virginia.gov To date, no comments have been received. 717SN0825-2017NOV15-CPC-RPT FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Mission The mission of Fire and Emergency Medical Services (EMS) is to protect life, property and the environment through a comprehensive fire and life safety program that ensures an adequate and timely response to emergencies. Response Times The proposed development is located in the urbanresponse zone for which Fire & EMS has a goal of responding to at least 90% of the calls for service in under seven(7) minutes. Fire and EMS is currently unable to meet that goal. Nearby Fire/EMS Facilities The Rivers BendFire Station, Company Number 18 Anticipated Fire & EMS Impacts/Needs Based on an average of 0.22 call per dwelling, it is estimated that this development will generate eleven (11) annual calls for Fire/EMS services. Additional Fire and EMS Comments When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. 817SN0825-2017NOV15-CPC-RPT SCHOOLS Staff Contact: Atonja Allen (804-318-8740) atonja_allen@ccpsnet.net Mission High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater access, flexible designs and locations that better meet the needs of the communities in which they are located. Capital Improvements The School Board FY2018 adopted Capital Improvement Plan (CIP) continues to support the 2013 voter approved school revitalization program that will replace or renovate ten schools and construct one new elementary school to add capacity in the Midlothian area of the county. The ten existing facilities that are part of the revitalization program are Providence Middle School, Monacan High School, Manchester Middle School, Beulah Elementary School, Enon Elementary School, Matoaca Elementary School, Harrowgate Elementary School, Reams Elementary School, Crestwood Elementary School, and Ettrick Elementary School. The project at Providence Middle School is currently in construction, a new Manchester Middle School is planned for construction on the existing school site, and the project at Monacan High School is complete. Additional information on the CIP can be found in the financial section of the CCPS Adopted Budget for FY2018. Anticipated School Impacts ElementaryMiddle High Total (1) 12 6 9 27 Anticipated Student Yield by School Type Schools Currently Serving AreaElizabeth ScottElizabeth Davis Thomas Dale Current Enrollment 988 1249 2266 Building Capacity (2) 1050 1675 3325 2016-17 (3) Functional Capacity 990 1324 3215 School Year Enrollment Percent of Total 100% 94% 70% Data Functional Capacity Total Number of Trailers 4 4 4 Number of Classroom Trailers 4 4 0 Note: Based upon average number of students per single family dwelling unit countywide at 0.48 students per unit. (1) Building capacity is the number of standard classrooms times the average class size of 25 students. (2) Functional capacity considers special programs occurring in the standard classrooms at less than average class size (3) 917SN0825-2017NOV15-CPC-RPT Public Facilities Plan Post 2020, the Plan recommends a new elementary school in the vicinity of Ruffin Mill Road, Enon Church Road and Ramblewood Drive, a new middle school in the vicinity of Chester and West Hundred Roads, and a new high school in the vicinity of Branders Bridge, Bradley Bridge, and Iron Bridge Roads north of Swift Creek, however at this time a budget has not been developed for the acquisition of land or construction of these school facilities as recommended in the Plan. LIBRARIES Staff Contact: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov Mission The public library system’s role in the county has expanded beyond its traditional function as a resource for information and materials, and now serves as a community gathering place for educational, cultural and informational services; community support during emergencies; economic development; and revitalization activities. Nearby Libraries Enon Library Public Facilities Plan The Public Facilities Plan suggests the Enon Library should be expanded/replaced or a new facility shall be constructed in the general vicinity at or near current site. Land for expansion or replacement of this facility or new facility has not been acquired. PARKS AND RECREATION Staff Contact: Stuart Connock (804-751-4484) ConnockS@chesterfield.gov To date, no comments have been received. 1017SN0825-2017NOV15-CPC-RPT UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov Existing Water and Wastewater Systems Currently Sizeof Closest Existing Connection Required by County Utility Type Serviced? Lines Code? Water No 8” & 12”Yes Wastewater No 8” Yes Additional Utility Comments This property is located in the mandatory water and wastewater connection area for residential subdivision development. Connection to the public water and wastewater systems will be required by county code and has been proffered by the applicant (Proffered Condition 8). There is an existing 12-inch waterline along Bermuda Orchard Lane and an existing 8-inch waterline along Enon Oaks Lane. The applicant is reminded of the Utilities Department standard to provide two supply points for redundant feeds in subdivisions of greater than 25 lots and to provide access to the public water for adjacent properties. There is an existing 8-inch gravity wastewater line along Enon Oaks Lane to the south of the site and an existing 8-inch gravity wastewater line along Back Stretch Court to the north of the site. The wastewater line along Enon Oaks Lane appears to have enough depth to serve the entire proposed development, however the applicant is advised that should a portion or all of the property need to be served by the wastewater line to the north along Back Stretch Court, easements will be needed from adjacent property owners in order to make the extension. The Utilities Department supports this case. 1117SN0825-2017NOV15-CPC-RPT Water and Wastewater Map - Existing Lines 1217SN0825-2017NOV15-CPC-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) WardR@chesterfield.gov Geography The subject property generally drains from south to north. The majority of the property drains to the northwest to an existing privately-owned pond, which discharges to Johnson Creek. A small portion of the property drains northeast to the existing roadside ditch and culvert under Bermuda Orchard Lane, which discharges to Johnson Creek. The entire property is located within the Johnson Creek Watershed. In the lower portion of the Johnson Creek Watershed, there are existing culverts under Enon Church Road which are inadequate and currently cause upstream flooding. Any increased runoff in this watershed upstream of the existing culverts will result in increased flooding along Johnson Creek and its tributaries. Environmental Features A Resource Protection Area Designation (RPAD) must be submitted and approved by the Department of Environmental Engineering-Water Quality Section prior to construction plan approval. In addition, wetlands shall not be impacted without approval from the U.S. Army Corps of Engineers and/or the Virginia Department of Environmental Quality. Drainage Due to existing inadequate culverts under Enon Church Road, any increased runoff from development in this watershed upstream of the existing culverts will result in increased flooding, which will impact private properties and public safety. As a result, the post-development 2, 10 and 100-year stormwater discharge rates shall not exceed the pre-development 2, 10 and 100 year- stormwater discharge rates, respectively. On-site detention/retention to pre-development rates will protect downstream properties and roadways from increased flooding. The applicant has offered Proffered Condition 9.a to address this impact. A large portion of the property drains to an existing old pond to the north. There have been concerns throughout the years with off-site drainage and the ability of the pond to handle any increase in runoff. As a result, stormwater discharge from the development shall be diverted directly to Johnson Creek to bypass the existing pond. The applicant has offered Proffered Condition 9.b to address this impact. Stormwater Management To protect downstream properties from a dam failure, if a stormwater management facility with a manmade embankment is proposed, a dam failure analysis may be required showing no homes will be detrimentally impacted. In addition, the dam embankment design should include, but not be limited to, a clay core or a syphon structure. The applicant has offered Proffered Condition 10to address this impact. 1317SN0825-2017NOV15-CPC-RPT The development is subject to the Part IIB technical criteria of the Virginia Stormwater Management Program Regulations for water quality and water quantity. Any areas of forest/open space used for stormwater quality compliance shall be outside the limits of the residential lots. 1417SN0825-2017NOV15-CPC-RPT CASE HISTORY Applicant Submittals 6/1/17 Application submitted 7/13/17 Revised application submitted 6/21, 7/27, Proffered conditionssubmitted 7/31, 8/17 & 8/24/17 Community Meeting 7/19/17Issues Discussed: Location and size of stormwater basin, drainage from basin to Proposed lot sizes and home sizes Discussion on connection to Enon Oaks Subdivision Tree retainment on property, preservation of vegetation along shared property with Enon Oaks, discussion of fence treatment Traffic concerns on area roadways, including Bermuda Orchard Lane Sidewalk and pedestrian connections in the subdivision Public utility connections required Phasing and completion timeline for development Treatment for driveways to individual homes Planning Commission 8/15/17Action – DEFERRED TO SEPTEMBER 19, 2017ON THE COMMISSION’S OWN MOTION WITH THE APPLICANT’S CONSENT. 9/19/17Action – DEFERRED TO OCTOBER 17, 2017 ON THE COMMISSION’S OWN MOTION WITH THE APPLICANT’S CONSENT. 10/17/17 Citizen Comments: No citizens spoke to this request. Recommendation –APPROVAL AND ACCEPTANCE OF THE PROFFERED CONDITIONS IN ATTACHMENT 1 Motion: Freye Second: Wallin AYES: Sloan, Jackson, Freye, Jones and Wallin The Board of Supervisors on Wednesday, November 15, 2017, beginning at 6:00 p.m., will consider this request. 1517SN0825-2017NOV15-CPC-RPT ATTACHMENT 1 PROFFERED CONDITIONS September 12, 2017 Note: Both the Planning Commission and Staff recommend acceptance of the following proffered conditions, as offered by the applicant. 1.Architectural Design Standards. All dwelling units developed on the Property shall be subject to the following architectural design standards: a.Exterior Facades. All dwelling units shall have brick, stone, EIFS, stucco or horizontal siding. Acceptable lap siding materials shall include natural wood or cement fiber board or may be premium quality vinyl siding with minimum wall thickness of .044 inches. Dutch lap style siding shall not be permitted. Synthetic Stucco (E.I.F.S.) siding shall be finished in a smooth, sand or level texture, no rough textures are permitted. b.Foundations. All foundations shall be constructed entirely of brick, stone, or a mixed combination of both. Synthetic or natural stucco foundations may be permitted for facades constructed entirely of stucco. c.Roofs. i.Varied Roof Line. Varied roof design and materials shall be used on facades of dwellings that face a street. Minimum main roof pitch shall be 6/12. ii.Roof Materials. Roofing material shall be dimensional architectural shingles with a minimum 30 year warranty. All flashing shall be copper or pre-finished aluminum (bronze or black). Standing seam metal may be used as a porch accent roof material. d.Porches and Stoops. i.Front Stoops and Front Porches. All front entry stoops and front porches shall be constructed with continuous masonry foundation wall or on 12”x12” masonry piers. Front porches shall be a minimum of five (5) feet deep. Space between piers under porches shall be enclosed with framed lattice panels. Handrails and railings shall be finished painted wood, vinyl rails or metal rail systems with vertical pickets or swan balusters. Pickets shall be supported on top and bottom rails that span between columns. e.Fireplaces, Chimneys and Flues. i.Chimneys. Side chimneys are permitted on roof planes or facades and must have masonry foundations. For gas fireplaces, metal flues may be used on the roof. All exterior materials and finishes used to enclose the chimney must be masonry or match the adjacent façade. 1617SN0825-2017NOV15-CPC-RPT ii.Direct Vent Fireplaces: Direct vent gas fireplace boxes which protrude beyond the exterior wall of the unit, are not permitted on facades facing a street. All exterior materials and finishes used to enclose the fireplace box must match the adjacent façade. f.Minimum dwelling sizes i.The minimum gross floor area for each single-family dwelling on Ranch/one story shall be 1,400 square feet and two stories shall be 1,600 square feet. g.Garages i.Front loaded attached garages shall be permitted to extend as far forward from the front line of the main dwelling as the front line of the front porch provided that the rooflines of the porch and garage are contiguous. Where the rooflines are not contiguous, garages shall be permitted to project a maximum of four (4) feet forward of the front porch. ii.Front loaded and corner side loaded garages shall have an upgraded garage door. An upgraded door is any door with a minimum of two (2) enhanced features. Enhanced features shall include windows, raised panels, decorative panels, arches hinge straps or other architectural features on the exterior that enhance the entry (i.e. decorative lintels, shed roof overhangs, arches, columns, keystones, eyebrows, etc.) Flat panel garage doors are prohibited. h.Variation in Front Elevations. i.Dwellings with the same elevations may not be located adjacent to, directly across from, or diagonally across from each other on the same street. This requirement does not apply to units on different streets backing up to each other. (P) 2.Front walks/Driveways a.All private driveways serving residential uses shall be constructed of brushed concrete, concrete pavers or asphalt). b.Front walks. A minimum of a three (3) foot concrete front walk shall be provided to the front entrance of each dwelling unit, to connect to drives, sidewalks or street. (P) 3.Landscaping and Yards. a.Sod and Irrigation. All front yards and corner yards shall be sodded and irrigated. b.Front Foundation Planting Bed. Foundation planting is required along all dwelling facades facing a street. Foundation Planting Beds shall be a minimum of 4’ wide, from the unit foundation. Planting beds shall include medium shrubs spaced a 1717SN0825-2017NOV15-CPC-RPT maximum of four (4) feet apart. Unit corners shall be visually softened with vertical accent shrubs (4’-5’) or small evergreen trees (6’-8’) at the time of planting. c.Supplemental Trees. Two (2) yard trees shall be planted or retained in the front yard of each dwelling with a minimum diameter of 2 inches measured at breast height. (4’ 10” above the ground). d.Buffer. Twenty (20)foot wide buffer shall be required along the rear property line of specified lots, as shown on Exhibit A. Except where necessary to accommodate access and utilities that run generally perpendicular through the buffer, existing trees with a caliper of four (4) inches or greater shall be maintained within the buffer except that any dead, diseased, or dying trees may be removed. (P) 4.Heating, Ventilation and Air Conditioning (HVAC) Units and Whole House Generators. a.Units shall initially be screened from view of public roads by landscaping or low maintenance material, as approved by the Planning Department. (P) 5.Dwelling Units. A maximum of fifty-five (55) dwelling units shall be permitted. (P) 6.Conceptual Plan. The site shall be designed as generally depicted on the concept plan dated September 12, 2017, entitled, “Mason Orchard, Bermuda District, Chesterfield County, Virginia” prepared by Bay Companies, Inc. (referred to herein as the “Concept Plan” attached hereto as Exhibit A provided, however the exact location of the lots, dwellings, streets, open space, common areas, and other improvements may be modified provided that the general intent of the Concept Plan is maintained.(P) 7.Cash Proffers a.The applicant, sub-divider, or assignee (s) shall pay $9,400 for each single-family dwelling unit to the County of Chesterfield for road improvements. b.Each payment shall be made prior to issuance of a building permit for dwelling unit unless state law modifies the timing of the payment. Should Chesterfield County impose impact fees at any time during the life of the development that are applicable to the property, the amount paid in cash proffers shall be in lieu of or credited toward, but in addition to, any impact fees, in a manner determined by the county.(B & M) 8.Water and Sewer a.Public water and wastewater shall be used. (U) 9.Post Development Runoff 1817SN0825-2017NOV15-CPC-RPT a.For portions of the property that are designated to drain to Johnson Creek, the post development runoff rate for the 2, 10, and 100 year storms shall not exceed the corresponding predevelopment runoff rate. b.Storm water drainage from the property, directed towards Tax ID 814-650-7955, will be piped directly to Johnson Creek, unless otherwise approved by the Department of Environmental Engineering. (EE) 10.Dam Failure Analysis. For any detention facility serving the site with a manmade embankment a dam failure analysis may be required, as determined by the Department of Environmental Engineering at the time of construction plan review, showing no homes will be detrimentally impacted. The dam embankment design should include, but not be limited to, a clay core or a syphon structure as determined by the Department of Environmental Engineering at the time of construction plan review.(EE) 11.Dedication. In conjunction with recordation of the initial subdivision plat or within 60 days from a written request by the Transportation Department, whichever occurs first, 35 feet of right of way along the west side of Bermuda Orchard Lane, measured from the centerline of that part of Bermuda Orchard Lane immediately adjacent to the property, shall be dedicated, free and unrestricted, to and for the benefit of Chesterfield County. (T) 12.Vehicular Access.Direct vehicular access from the property to Bermuda Orchard Lane shall be limited to one public road, generally aligning Green Orchard Drive. The exact location shall be approved by the Transportation Department.(T) 13.Road Improvements. In conjunction with initial development, the following road improvements shall be completed, as determined by the Transportation Department: a.Construction of additional pavement along Bermuda Orchard Lane to provide left and right turn lanes at each approved access. b.Construction of a sidewalk along the west side of Bermuda Orchard Lane for the entire property frontage. c.Dedication to Chesterfield County, free and unrestricted, of any additional right- of-way (or easements) required for the improvements identified above.(T) 1917SN0825-2017NOV15-CPC-RPT ATTACHMENT 2 EXHIBIT A – CONCEPTUAL LAYOUT PLAN 2017SN0825-2017NOV15-CPC-RPT