Loading...
17SN0791 CASE NUMBER: 17SN0791 APPLICANTS: Joseph Ziadeh Santana CHESTERFIELD COUNTY, VIRGINIA MIDLOTHIAN DISTRICT STAFF’S ANALYSIS AND RECOMMENDATION Board of Supervisors Hearing: FEBRUARY 28, 2018 BOS Time Remaining: 365 DAYS Applicants’ Contact: JOSEPH SANTANA (804-790-9020) Planning Department Case Manager: DARLA ORR (804-717-6533) 6.9 Acres – 11188 Robious Road REQUEST Conditional Use to permit a group care facility in an Agricultural (A) Zoning District. Note: A. Conditions may be imposed or the property owner may proffer conditions. B.Proffered conditions and exhibits are located in Attachments 1 – 3. SUMMARY An assisted living and memory care facility is planned. Specifically, care for up to 132 individuals is planned in a two-story facility as identified in the Conceptual Site Layout and Elevations in Exhibits A and B in Attachments 3 and 4. RECOMMENDATIONS PLANNING APPROVAL COMMISSION STAFF PLANNING – DENIAL While the applicant has proffered conditions that add quality components to the development comparable to surrounding area development, the proposed zoning and land use do not comply with the recommendations of the Comprehensive Plan as it fails to aggregate surrounding properties. TRANSPORTATION – APPROVAL As conditioned, the traffic impact of the development will be addressed. Providing a FIRST CHOICE community through excellence in public service SUMMARY OF IDENTIFIED ISSUES Department Issue Failure to aggregate surrounding properties will likely not achieve the PLANNING highest and best land use suggested by the Plan. 217SN0791-2018FEB28-BOS-RPT 317SN0791-2018FEB28-BOS-RPT Comprehensive Plan Classification: MEDIUM-HIGH DENSITY RESIDENTIAL The designation suggests the property is appropriate for minimum 4.0 to 8.0 dwellings per acre. Surrounding Land Uses and Development Belvedere apartments Ballard Oaks& Greenfield Subdivisions Sunrise Assisted Living Vacant Cranbeck Road Single-family uses Vacant Robious Road Clairmont at Chesterfield apartments 417SN0791-2018FEB28-BOS-RPT PLANNING Staff Contact: Darla Orr (804-717-6533) orrd@chesterfield.gov Proposal The applicant plans to demolish the existing structures on the request property and construct a 132-bed group care facility. The applicant has indicated that the facility will provide resident services and memory care to elderly adultsrequiring rehabilitation or personal services. A group care facility is first permitted in a Neighborhood Office (O-1) Zoning District. The subject property is zoned Agricultural (A). Approval of a Conditional Use is required to permit a group care facility in an Agricultural (A) District. The applicant worked with area property owners to finalize the proposal, offering conditions to address their questions/concerns relative to: Buffers and prohibiting access to Ermavedo Drive Maximum building height and facility size (number of beds) Parking, hours, and lighting Drainage The following provides an overview of the development standards offered by the applicant : General Overview Requirements Details Development will generally conform to plan Conceptual Plan Existing buildings to be demolished Exhibit A and Proffered Conditions 6 and 7 Maximum of 132 Number of Beds Proffered Condition 5 Except where Agricultural (A) standards are greater, will meet Development Standards Emerging Growth District Standards for office use Proffered Condition 4 50-foot buffer along northern property boundary (adjacent to Ballard Oak subdivision) Buffers 25-foot wide buffer along side property boundaries Proffered Condition 8 Compatible with elevations in Exhibit B Buildings not exceed 2 stories 60% of front facades and side or rear facades visible to public Architecture streets shall be brick or stone Vinyl, plywood and metal siding not permitted Proffered Conditions 10 and 11 Required parking and drives paved as required by Ordinance Overflow parking may use permeable pavement Parking and Lighting Freestanding light fixtures maximum height of 15 feet Proffered Conditions9 and 15 Solid waste storage areas cannot be serviced between 8 p.m. Servicing Hours Limitation and 7 a.m. Proffered Condition 14 517SN0791-2018FEB28-BOS-RPT USE AND COMPREHENSIVE PLAN Area properties are zoned for a mix of office and single and multi-family residential uses, or area zoned Agricultural and occupied by single-family dwellings or remain vacant. Two (2) vacant properties to the west (11230 and 11240 Robious Road, containing 3.6 acres) and three (3) properties to the east (2001 Ermavedo Drive and 11160 and 11170 Robious Road containing 5.7 acres) all have development potentialwith a combined area of 9.3acres The Comprehensive Plan suggests the block, including the subject property, fronting the north line of Robious Road between Cranbeck Road to the west, Ballard Oaks subdivision to the north, and Greenfield subdivision to the east, as an area appropriate for medium-high density residential development. Ballard Oaks subdivision Greenfield subdivision While the Plan would not suggest O-1 zoning, a district where agroup care facility is first permitted, with the aggregation of properties within this block, staff believes the proposed use may be appropriate in achieving land use transitionbetween Robious Road and single family residential use to the north and east. Land aggregation is encouraged by the Plan where development of individual parcels would be constrained in size or shape in consideration of compliance with ordinance development standards and compatibility or transition. Without aggregation, development of the remaining properties (3.6 acres and 5.7 acres east and west of the subject property) will be adversely impacted due to their size and separation. Staff is unable to support this request. 617SN0791-2018FEB28-BOS-RPT COUNTY DEPARTMENT OF TRANSPORTATION Staff Contact: Jim Banks (804-748-1037) banksj@chesterfield.gov The applicant plans to develop a group care facility with a maximum of 132 beds (Proffered Condition 5). Based on trip generation rates for assisted living, development could generate approximately 330 average daily trips. Traffic generated by development of the property would be initially distributed along Robious Road. Robious Road is a major arterial with a recommended right of way width of 90 feet, as identified on the County’s Thoroughfare Plan. Robious Road is afour-lane divided facility. In 2015, the traffic count on Robious Roadwas 20,316vehicles per day (Level of Service ‘B’). Section 19.1-231 of the County Code outlines the general requirements to meet the needs of the traffic generated by a proposed development, including acceptable levels of service. The applicant has offered: Right of Way Dedication (Proffered Condition 1) 45 feet along Robious Road for the property frontage Vehicular Access Control (Proffered Condition 2) One (1) accessand one (1) emergency access to Robious Road. To address citizen concerns, applicant has proffered no access to Ermavedo Drive. Road Improvements (Proffered Condition 3) Right turn lane at the approved access to Robious Road. Staff supports the request. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Jonathan Phillippe (804-674-2560) jonathan.phillippe@vdot.virginia.gov To date, no comments have been received. FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Mission The mission of Fire and Emergency Medical Services (EMS) is to protect life, property and the environment through a comprehensive fire and life safety program that ensures an adequate and timely response to emergencies. Nearby Facilities The Midlothian Fire Station, Company Number 5 The Forest View Volunteer Rescue Squad 717SN0791-2018FEB28-BOS-RPT Additional Fire and EMS Comments A second access will be required for the development. To address concerns of area citizens, no access from the property is permitted to ErmavadoDrive. Both accesses are planned to Robious Road. Since the spacing of the entrances will not meet separation distances required by Transportation and VDOT, the FireDepartment will support an emergency access as the second entrance. The emergency access will have to meet Fire and EMS standards. (Proffered Conditions 2 and7) When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov The proposal’s impacts on the County’s utility system are detailed in the chart below: Water and Wastewater Systems Currently Size of Closest Connection Required by County Code? Serviced? Existing Line Water No 16” & 8”Yes Wastewater Yes and No 15”Yes Additional Information Both parcels are located in the mandatory water and wastewater connection areas for non- residential development and thus connection to public water and wastewater is required. Water and wastewater are both available in Robious Road. The owner/developer has proffered the use of public water and wastewater. (Proffer Condition #12). The existing building located at 11188 Robious Road is currently connected to the public water and wastewater systems. After demolition, the proposed new building(s) may require an increase to the existing water service and water metersize. If a larger water service/meter is needed, a new service line and meter box will need to be installed and the difference in connection fees would be required prior to setting a new meter. Existing water services and laterals not utilized as part of the proposed development must be abandoned per the Water and Sewer Specifications and Procedures. The existing building located at 11210 Robious Road is currently connected to the public water system. There is a wastewater lateral installed to the property however it does not appear the structure was ever connected. Any new construction on this property will be required to connect to both public water and wastewater. The proposed use may require an increase to the water service and water meter size. If a larger water service/meter is needed, a new service line and meter would need to be installed and the difference in connection fees would be required prior to setting the new meter. Existing water services and laterals not utilized as part of the proposed development must be abandoned per the Water and Sewer Specifications and Procedures. Utilities supports this case. 817SN0791-2018FEB28-BOS-RPT 917SN0791-2018FEB28-BOS-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) wardr@chesterfield.gov Geography The majority of the subject properties drains north and northeast into the existing Ballard Oaks subdivision and then into an existing storm sewer system in the Greenfield subdivision. The storm sewer outfalls into the headwaters of Powhite Creek. The front portions of the properties drain into the existing storm sewer system along Robious Road, which outfalls into an unnamed tributary to Pocoshock Creek. The northern 65% of the subject properties is located within the Powhite Creek Watershed. The southern 35% is located within the Falling Creek Watershed. Environmental Features A Resource Protection Area Designation (RPAD) must be approved by the Environmental Engineering-Water Quality Section prior to the submittal of anysite plans.Wetlands shall not be impacted without approval from the U.S. Army Corps of Engineers and/or the Virginia Department of Environmental Quality. Drainage A portion of the subject properties currently drains north and east towards and into existing residential lots in the Greenfield and Ballard Oaks subdivisions. The existing ditches and culverts within these subdivisions are older systems which were not designed to handle runoff from a high intensity commercial development; therefore, to the maximum extent practicable, drainage shall be diverted into the existing storm sewer system along Robious Road. In addition, drainage shall be designed so that runoff from buildings, sidewalks, driveways, and other impervious surfaces is directed away from these existing lots. The applicant has offered Proffered Conditions 13.A and 13.B to address this impact. The existing roadside ditches and culverts in the Ballard Oaks subdivision should be evaluated to verify that existing private properties will not be negatively impacted by increased stormwater runoff created by the development. For the portion of the property which drains to the Ballard Oaks subdivision, the maximum post-development discharge rate for the 10-year storm shall be based on the maximum capacity of the existing roadside ditches and culverts along Ermavedo Drive. In addition, the 2-year and 100-year post-development peak discharge rates shall not exceed the 2-year and 100-year pre-development peak discharge rates, respectively. The applicant has offered Proffered Condition 13.C to address this impact. To protect downstream properties from flooding in the event of a dam failure, any detention facility serving the development shall be a dry facility constructed below the existing ground, such that no manmade compacted embankment is required. If some level of manmade embankment is necessary, a dam failure analysis will be required to verify that no homes will be detrimentally impacted. The dam embankment design should include, but is not limited to, a clay core and/or a syphon structure. The applicant has offered Proffered Condition 13.D to address this impact. Stormwater Management The development of the subject property will be subject to the Part IIB technical criteria of the VSMP Regulations for water quality and quantity. Any areas of forest/open space used for stormwater quality compliance must be recorded within an easement prior to issuance of a building permit. 1017SN0791-2018FEB28-BOS-RPT CASE HISTORY Applicant Submittals 2/14/17 Application submitted 12/1, 12/6 Proffered conditions and exhibits submitted. and 12/21/17 Community Meetings 3/16/17Issues Discussed: Access into request property and potential emergency access 8/7/17 Issues Discussed: Plans to remodel and use existing building Proposed new building – reduce height and provide elevations Use of Ermavedo Drive for emergency access; possibility of emergency access to Robious Road in addition to main access On-site and overflow parking Stormwater run-off Potential to reduce proposed number of beds Buffer adjacent to neighborhood and property values 10/16/17 Issues Discussed: No access to Ermavedo Drive Demolition of existing structures Architectural standards to include 60% of front facades constructed with brick or stone masonry Building height Buffer along the northern property boundary Planning Commission 10/17/17 Action – DEFERRED TO NOVEMBER 21, 2017 ON ITS OWN MOTION WITH THE APPLICANT’S CONSENT. 11/21/17 Action – DEFERRED TO JANUARY 16, 2018 ON ITS OWN MOTION WITH THE APPLICANT’S CONSENT. 1/16/18Citizen Comments: A citizen requested confirmation that all of the existing buildings will be demolished. Commission Discussion: Mr. Jones expressed support for the case noting that the applicant had worked to address concerns of area citizens. Recommendation – APPROVAL SUBJECT TO THE PROFFERED CONDITIONS IN ATTACHMENT 1 Motion: Jones Second: Sloan AYES: Sloan, Jackson, Freye, Jones and Wallin The Board of Supervisors on Wednesday, February 28, 2018, beginning at 6:00 p.m., will consider this request. 1117SN0791-2018FEB28-BOS-RPT ATTACHMENT 1 PROFFERED CONDITIONS (December 21, 2017) Note: The following proffered conditions are recommended by the Planning Commission. 1.Dedication.Prior to any site plan approval, or within sixty (60) days of a written request by the Transportation Department, whichever occurs first, forty-five (45) feet of right- of-way on the north side of Robious Road, measured from the centerline of that part of Robious Road immediately adjacent to the Property, shall be dedicated, free and unrestricted, to and for the benefit of Chesterfield County. (T) 2.Access. Direct vehicular access from the Property to Robious Road shall be limited to one (1) entrance/exit and one (1) emergency access. The exact location and design of these accesses shall be approved by the Transportation Department and the Fire Department. No direct vehicular access shall be permitted to Ermavedo Drive. (T and F) 3.Road Improvements. Prior to issuance of a certificate of occupancy on the Property, the following road improvements shall be completed, as determined by the Transportation Department: a.Construction of an additional pavement along the westbound lanes of Robious Road at the approved access to provide a separate right turn lane; and b.Dedication to Chesterfield County, free and unrestricted, of any additional right- of-way (or easements) required for the improvements identified above. (T) 4.Development Standards. Except where the underlying Agricultural (A) District standards are more restrictive, development of the property shall conform to the Zoning Ordinance requirements for Corporate Office (O-2) development within the Emerging Growth Design District. (P) 5.Maximum Number of Beds. The assisted living/memory care facility shall be limited to a maximum of 132 beds. (P and BI) 6.Demolition of Existing Structures. Prior to the issuance of a building permit for the assisted living/memory care facility, all existing structures on the properties shall be demolished. (P and BI) 7.Conceptual Plan. The plan, dated November 22, 2017 and last revised November 30 prepared by E. D. Lewis and Associates and identified as Exhibit A, shall be considered the conceptual site plan. Development of the site shall generally conform with this plan. (P) 8.Buffer.A fifty (50) foot wide buffer shall be provided along the northern property boundary adjacent to Ballard Oak subdivision and twenty-five (25) foot buffers shall be provided along the side property boundaries. Such buffers shall be inclusive of setbacks and shall comply with ordinance standards for fifty (50) foot buffers.(P) 1217SN0791-2018FEB28-BOS-RPT 9.Parking. A minimum of 42 parking space shall be provided in accordance with Zoning Ordinance standards. Spaces provided in excess of ordinance required spaces shall be permitted to be designed to incorporate the use of permeable pavement, such as, but not limited to, permeable concrete, permeable asphalt or permeable paver systems. (P and EE) 10.Building Height. Maximum height for all buildings shall be limited to two (2) stories. (P) 11.Architectural Standards. Architectural treatment of buildings shall be generally compatible with Exhibit B, dated November 22, 2017 and last revised November 30 prepared by E. D. Lewis and Associates. In addition, buildings shall be subject to the following: A minimum of 60% of the front facades of all buildings shall be brick or stone masonry. The side or rear façade of a building that is visible from public streets shall have at least 60% brick or stone masonry. The height of the brick and stone shall be permitted to vary to allow for a mixture of design features. Measurement of the requirement for masonry façade treatment shall be exclusive of roof gable ends, windows, doors, balconies, porches and sunrooms. Horizontal lap siding shall be manufactured from natural wood or cement fiber board. Vinyl, plywood and metal siding are not permitted. (P and BI) 12.Utilities. The public water and wastewater systems shall be used. (U) 13.Drainage/Stormwater. To the maximum extent practicable, drainage shall be diverted to the existing storm A. sewer system along Robious Road. No impervious areas shall sheet flow through the Greenfield and Ballard Oaks B. Subdivisions. For the portion of the property which drains or will drain to the Ballard Oaks C. Subdivision, the maximum post-development drainage discharge rate for the 10- year storm shall be based on the maximum capacity of the existing roadside ditch and driveway culverts along Ermavedo Drive. In addition, the 2-year and 100-year post-development peak discharge shall not exceed the 2-year and 100-year pre- development peak discharge, respectively. To protect downstream properties from flooding in the event of a dam failure, any D. detention facility serving the property should be a dry facility below the existing ground so no manmade compacted embankment is required. If some level of manmade embankment is necessary, a dam failure analysis will be required showing no homes will be detrimentally impacted. The dam embankment design should include, but not be limited to, a clay core or a syphon structure. (EE) 14.Servicing Hours Limitations. Solid waste storage areas shall not be serviced between the hours of 8:00 p.m. and 7:00 a.m. A sign, not to exceed six (6) square feet in area, designating the hours which such solid waste storage areas may be serviced shall be prominently posted. (P) 15.Lighting: Freestanding light fixtures shall not exceed a height of fifteen (15) feet (P). 1317SN0791-2018FEB28-BOS-RPT ATTACHMENT 2 EXHIBIT A - CONCEPTUAL SITE LAYOUT 1417SN0791-2018FEB28-BOS-RPT ATTACHMENT 3 EXHIBIT B - CONCEPTUAL ELEVATIONS 1517SN0791-2018FEB28-BOS-RPT