18SN0710
CASE NUMBER: 18SN0710
APPLICANT: Hamlin Investments LLC
CHESTERFIELD COUNTY, VIRGINIA
BERMUDA DISTRICT
AND RECOMMENDATION
Board of Supervisors Hearing:
MAY 23, 2018
Board of Supervisors Time Remaining:
365 DAYS
ANDREW M. SCHERZER (804-794-0571)
MICHAEL BARR (804-897-3002)
1.0 Acre 4201 Hamlin Creek Parkway
Planning Department Case Manager:
JANE PETERSON (804-748-1045)
REQUEST
Rezoning from General Business (C-5) to Community Business (C-3) plus conditional use planned
development to permit exceptions to ordinance requirements. Specifically, reductions in a required
buffer and parking setbacks are proposed.
Notes:
A.Conditions may be imposed or the property owner may proffer conditions.
B.Proffered conditions, Textual Statement, preliminary sample sketch and approved zoning conditions are
located in Attachments 1 - 4.
SUMMARY
Commercial uses are proposed. Proffered conditions limit uses to those permitted by right or with
restrictions in the Neighborhood Business (C-2) District with exclusions, plus a fast food or drive-in
restaurant limited to service of primarily coffee or donuts.
To accommodate site access, an exception to a required 75-foot buffer and a reduction in the
required 30-foot driveway setback are requested along the southern property line adjacent to
residentially-zoned property. A variable width buffer and fencing are proposed in this location.
RECOMMENDATIONS
PLANNING APPROVAL
COMMISSION
APPROVAL
The proposed C-3 is closer in alignment to the Community Business (C-3)
uses anticipated by the Plan as part of a Community Mixed Use area.
STAFF
As conditioned, the uses provide a more appropriate land use transition
to existing residential development south of the request property.
Exceptions provide flexibility to accommodate development while
maintaining sufficient separation from adjacent residential uses.
Providing a FIRST CHOICE community through excellence in public service
SUMMARY OF IDENTIFIED ISSUES
Department Issue
An exception to Zoning Ordinance will be required from the Board of
ENVIRONMENTAL
Supervisors for any improvements proposed within the limits of the
ENGINEERING
Resource Protection Area.
218SN0710-2018MAY23-BOS-RPT
318SN0710-2018MAY23-BOS-RPT
Comprehensive Plan (THE CHESTER PLAN)
Classification: COMMUNITY MIXED USE
The designation suggests the property is appropriate for community-scale commercial uses, including
shopping centers, service and office uses, that serve community-wide trade areas.
Surrounding Land Uses and Development
Chester
Rd
Hamlin Creek
Pkwy
Commercial
Commercial
Self
storage
Vacant
Hilltop Farms
Subdivision
418SN0710-2018MAY23-BOS-RPT
PLANNING
Staff Contact: Jane Peterson (804-748-1045) petersonj@chesterfield.gov
Zoning History
Case Number Request
Rezoning to Residential (R-12) of 128.3 acres; Residential (R-15) of 12 acres;
and General Business (B-3) of 47 acres. Single family uses were proposed,
79SN0118
along with General Business (B-3) uses fronting Chester Road and Route 288.
Approved
Uses within the B-3 District (now C-5) property limited primarily to those
(1/1980)
permitted in the Community Business (B-2) District (now C-3), with specified
B-3 (now C-5) uses, as well as prohibited uses (Attachment 4).
Proposal
Commercial uses are proposed, as limited by proffered conditions. In addition, exceptions to
Ordinance requirements to provide a variable width buffer and reduced driveway setback along
the southern property boundary adjacent to Hilltop Farms subdivision, all as outlined below.
Uses
The request property is zoned General Business (C-5). Conditions of Case 79SN0118 limit uses to
those permitted by right or with restrictions in the Community Business (C-3) District, plus
additional and prohibited uses. Rezoning to Community Business (C-3) is proposed. Proffered
conditions limit uses to those permitted by right or with restrictions in the Neighborhood Business
(C-2) District, plus additional and prohibited uses.
The following chart outlines current and proposed uses, both permitted and prohibited:
USES
CURRENT C-5 PROPOSED C-3
(CASE 79SN0118) (CASE 18SN0710)
C-3 uses, plus two C-5 uses: C-2 uses, plus one C-3 use:
Fast food or drive-in restaurant
Motel
PERMITTED
limited to service of primarily coffee
Utility trailer and truck
or donuts
rental
Feed, seed, fuel and ice sales Public utility service buildings
Office-warehouse (warehouse Veterinary clinics
limited to 25,000 sf) (Note: Of the prohibited uses listed
under Case 79SN0118, the two uses
Motor vehicle sales, service and
PROHIBITED
noted herein are the only uses that
repair
would otherwise be permitted in a C-2
Public utility service buildings
District)
Veterinary hospitals, boarding
kennels or clinics
518SN0710-2018MAY23-BOS-RPT
Buffer and Setback Exceptions
With the proposed C-3 zoning, a 75-foot buffer would be required along the southern boundary
adjacent to property zoned Residential (R-9), developed as lots within the Hilltop Farms
subdivision.
The Hilltop Farms development was zoned in 1984, subsequent to the commercial zoning of the
request property. The need for a buffer adjacent to this C-5 parcel was acknowledged in the
zoning case for this subdivision. As such, the subdivision was recorded with the provision of a
fifty (50) foot buffer adjacent to this C-5 parcel, as depicted below.
With this request, the 75-foot buffer adjacent to Hilltop Farms would become a variable width
buffer, and landscaped in accordance with Ordinance requirements for 50-foot buffers. In
addition, a solid privacy fence would be provided from the eastern edge of the Hilltop buffer
(lot 14), 150 feet west along southern boundary of the request property. This variable width
buffer and fence location are depicted on the Preliminary Sample Sketch (Attachment 3).
The Ordinance requires a 30-foot side yard parking/driveway setback when adjacent to
residentially-zoned property, reduced to 10 feet when adjacent to commercially-zoned
property. To accommodate development access, a reduction in this setback is requested to 10
feet along the southern boundary adjacent to Hilltop Farms (lot 14), and subject to provisions
for the variable width buffer. This setback is also depicted in Attachment 3.
618SN0710-2018MAY23-BOS-RPT
Dumpster Servicing Hours
The Ordinance limits the servicing of dumpsters located in proximity to residentially-zoned
property to between the hours of 6 a.m. and 9 p.m. Proffered Condition 4 further restricts these
hours to between 7 a.m. and 7 p.m.
Given the following, staff supports the proposed zoning and Ordinance exceptions:
The proposed C-3 is closer in alignment to the Community Business (C-3) uses
anticipated by the Plan as part of a Community Mixed Use area.
As conditioned, the uses provide a more appropriate land use transition to existing
residential development south of the request property.
The proposed variable width buffer in combination with the Hilltop Farms buffer,
provides both a physical and visual separation consistent with that typically anticipated
between C-2/C-3 uses and residential developments.
COUNTY DEPARTMENT OF TRANSPORTATION
Staff Contact: Steve Adams (804-751-4461) adamsst@chesterfield.gov
The /ƚƒƦƩĻŷĻƓƭźǝĻ tƌğƓ, which includes the ŷƚƩƚǒŭŷŅğƩĻ tƌğƓ, identifies county-wide
transportation needs that are expected to mitigate traffic impacts of future growth. The
anticipated traffic impact of the proposal has been evaluated and it is anticipated to have a
similar impact based on the existing zoning, which will be minimal.
VIRGINIA DEPARTMENT OF TRANSPORTATION
Staff Contact: Jonathan Phillippe (804-674-2560) jonathan.phillippe@vdot.virginia.gov
To date, no comments have been received.
FIRE AND EMERGENCY MEDICAL SERVICES
Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov
Nearby Fire and Emergency Medical Service (EMS) Facilities
Fire Station The Centralia Fire Station, Company Number 17
EMS Facility The Centralia Fire Station, Company Number 17
Additional Fire and EMS Comments
When the property is developed, the number of hydrants, quantity of water needed for fire
protection, and access requirements will be evaluated during the plans review process.
718SN0710-2018MAY23-BOS-RPT
UTILITIES
Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov
The are detailed in the chart below:
Water and Wastewater Systems
Currently Size of Existing Line Connection Required by County Code?
Serviced?
Water No 16 Yes
Wastewater No 30 Yes
Additional Information:
This property is located in the mandatory water and wastewater connection area for non-
residential development. Connection to the public water and wastewater systems will be required
by county code.
The applicant has proffered to connect to public water and wastewater. (Proffered Condition 3)
818SN0710-2018MAY23-BOS-RPT
918SN0710-2018MAY23-BOS-RPT
ENVIRONMENTAL ENGINEERING
Staff Contact: Rebeccah Ward (804-748-1028) wardr@chesterfield.gov
Geography
The majority of the subject property generally drains from east to west directly to Great
Branch, which parallels the western property line along Chester Road. The entire property is
located within the Proctors Creek Watershed.
Environmental Features
A Resource Protection Area Designation was completed by the applicant, and reviewed and
confirmed by the Department of Environmental Engineering - Water Quality Section. The western
third of the property contains Resource Protection Area (RPA) along Great Branch. The
Preliminary Sample Sketch shows parking encroaching into the RPA. A Water Quality Impact
Assessment must be submitted to and approved by the Department of Environmental Engineering
and the Board of Supervisors for any improvements which encroach into the RPA.
The western half of the property contains 100-year floodplain along Great Branch. The Preliminary
Sample Sketch shows parking and a portion of the building encroaching into the floodplain.
Approval from FEMA and/or the Department of Environmental Engineering is required prior to any
activities within the floodplain.
Stormwater Management
The development of the subject properties will be subject to the Part IIB technical criteria of the
VSMP Regulations for water quality and quantity.
1018SN0710-2018MAY23-BOS-RPT
CASE HISTORY
Applicant Submittals
12/8/17 Application submitted
3/20/18 Application amended; revised proffered conditions and textual statement
submitted
4/3/18 Revised proffered conditions and textual statement submitted.
Community Meeting
1/31/18 No citizens attended this meeting.
Planning Commission
2/20/18 Action DEFERRED TO APRIL 17, 2018
3/20/18 Citizen Comments:
No citizens spoke to this case.
Recommendation APPROVAL AND ACCEPTANCE OF THE PROFFERED
CONDITIONS IN ATTACHMENT 1
Motion: Jones Second: Stariha
AYES: Sloan, Jackson, Jones and Stariha ABSENT: Freye
The Board of Supervisors on Wednesday, May 23, 2018, beginning at 6:00 p.m., will
consider this request.
1118SN0710-2018MAY23-BOS-RPT
ATTACHMENT 1
PROFFERED CONDITIONS
(April 3, 2018)
Note: Both the Planning Commission and Staff recommend acceptance of the following
proffered conditions, as offered by the applicant.
1.Master Plan. The Textual Statement, last revised April 3, 2018, shall be considered the
Master Plan. (P)
2.Uses. Permitted uses shall be limited to the following:
a.Those uses permitted by right and with restrictions in the C-2 District, excluding
a veterinary clinic and utility uses requiring a structure;
b.Restaurant, fast food or drive-in, provided the primary business (a minimum of
fifty (50) percent of its gross receipts) is the sale of coffee or donuts. (P)
3.Utilities. Public wastewater and water systems shall be used. (P)
4.Dumpster Service. Dumpster service shall not be allowed between 7:00 p.m. and 7:00
a.m. (P)
1218SN0710-2018MAY23-BOS-RPT
ATTACHMENT 2
TEXTUAL STATEMENT
(April 3, 2018)
I.Requirements and Exceptions.
A.Buffer. An exception to the seventy-five (75) foot buffer requirement along the
adjacent residential use. The developer/owner will instead provide the following:
i.A variable width buffer, as identified on the Preliminary Sample Sketch
dated April 3, 2018, shall be maintained in accordance with Zoning
Ordinance requirements for fifty (50) foot buffers along the southern
property line adjacent to the residential properties, identified as Tax IDs
787-664-5165, 787-664-6168, 787-664-6964, 787-664-7665, and 787-
664-8364.
B.Fence. A six (6) foot natural-colored solid wood or composite material fence shall
be installed along the southern property line, starting from 50 feet inward of the
property located on Tax ID 787-664-5165, extending approximately 150 feet
west, as generally shown on the Preliminary Sample Sketch dated April 3, 2018.
C.Setbacks. The parking setback along the southern property line adjacent to Tax
ID 787-664-5165, as identified on the Preliminary Sample Sketch dated April 3,
2018, may be reduced to 10 feet provided such reduction still accommodates
the variable width buffer described herein.
1318SN0710-2018MAY23-BOS-RPT
ATTACHMENT 3
PRELIMINARY SAMPLE SKETCH
1418SN0710-2018MAY23-BOS-RPT
ATTACHMENT 4
APPROVED CONDITIONS (CASE 79SN0118)
1518SN0710-2018MAY23-BOS-RPT
1618SN0710-2018MAY23-BOS-RPT
1718SN0710-2018MAY23-BOS-RPT