Loading...
94SN0199May 25, lg94 BS REQUEST ANALYSIS AND RECOMMENDATION 94SN0199 Zwerdling, Oppleman and Paciocco Matoaca Magisterial District South of Hull Street Road REQUEST: Rezoning from Light Industrial (I-1) to General Business (C-5). PROPOSED LAND USE: General commercial uses are planned. PLANNING COMMISSION RECOMMENDATION RECOMMEND APPROVAL. STAFF RECOMMENDATION Recommend approval for the following reasons: Although the Northern Area Land Use and Transportation Plan designates the property for light industrial use, properties to the east and west along this portion of Hull Street Road are zoned and developed commercially. The proposed General Business (C-5) zoning is compatible with, and representative of, area general commercial development trends. Bo The request property is currently zoned for a mix of light industrial and general commercial uses. Rezoning to General Business (C-5) would allow a similar mix of uses. C. The development standards of the Zoning Ordinance ensure quality development. (NOTE: THE ONLY CONDITION THAT MAY BE IMPOSED IS A BUFFER CONDITION. THE PROPERTY OWNER MAY PROFFER OTHER CONDITIONS.) GENERAL INFORMATION Location: Fronts the south line of Hull Street Road and the east line of Price Club Boulevard. Tax Map 49-11 (1) Parcels 12 and 28 (Sheet 14). Existing Zoning: I-1 with Conditional Use Planned Development Size: 1.5 acres Existing Land Use: Industrial or vacant Adjacent Zoning & Land Use: North - South - East West A, C-3, C-5 and I-1 with Conditional Use Planned Development; Single family residential, office or commercial I-1 with Conditional Use Planned Development; Vacant I-1 with Conditional Use Planned Development; Industrial C-5, and C-3 with Conditional Use; Commercial PUBLIC FACILITIES Utilities: Public Water System There is an existing 8 inch water line located on-site. In addition, there is an existing 12 inch water line that fronts the request site. The use of the public water system is required by Ordinance. Results of a computer simulated flow test indicate that sufficient flow and pressure should be available to meet domestic and fire protection demands of the proposed use. Fire flow requirements are established and coordinated through Fire Administration. Public Wastewater System There is an existing 8 inch wastewater line located on-site. The use of the public wastewater system is required by Ordinance. The results of a computer simulated 2 94SN0199/WP/MAY25L hydraulic analysis indicate that sufficient capacity should be available to accommodate the domestic waste flows generated by the proposed use. Environmental: Drainage and Erosion: Property drains south to Horners Run via storm sewers and ultimately to Pocoshock Creek. No existing or anticipated on- or off-site drainage or erosion problems. Off- site easements and drainage improvements may be necessary to accommodate increased runoff from development. Fire Service: Wagstaff Fire Station, Company #10. Provide County water and fire hydrant placement for fire protection purposes in compliance with nationally recognized standards (i.e., National Fire Protection Association and Insurance Services Office). The proposed zoning and land uses will not generate additional need for fire protection services. Transportation: This proposed rezoning will have minimal impact on the existing transportation network. LAND USE General Plan: Lies within the boundaries of the Northern Area Land Use and Transportation Plan which designates the property for light industrial use. Area Development Trends: Properties along this portion of Hull Street Road are zoned and developed for a mix of office, commercial and industrial uses. Zoning History: On October 28, 1981, the Board of Supervisors, upon a favorable recommendation by the Planning Commission, approved rezoning from Agricultural (A) to Light Industrial (M-l) to permit general commercial uses and setback exceptions on the southernmost and easternmost portions of the request property (Case 81S104). 3 94SN0199/WP/MAY25 L On September 28, 1983, the Board of Supervisors, upon a favorable recommendation by the Planning Commission, approved rezoning from Agricultural (A) to Light Industrial (M-l) with Conditional Use Planned Development to permit a mini- warehouse facility and setback exceptions on the westernmost portion of the request property (Case 83S098). On November 28, 1984, the Board of Supervisors approved an amendment to Case 83S098 to permit revision of the approved Master Plan plus a heating and air conditioning business on the westernmost portion of the request property (Case 84S179). On April 26, 1989, the Board of Supervisors approved an amendment to Case 84S179 to permit contractor's shops on the westernmost portion of the request property (Case 89SN0162). Site Design: The request property lies within the Hull Street Road Emerging Growth Area. Redevelopment of the site or new construction must conform to the development standards of the Zoning Ordinance which address access, parking, landscaping, architectural treatment, setbacks, signs, buffers, utilities, and screening of dumpsters and loading areas. Architectural Treatment: Within Emerging Growth Areas, no building exterior which would be visible to any public right of way may consist of architectural materials inferior in quality, appearance, or detail to any other exterior of the same building. There is, however, nothing to preclude the use of different materials on different building exteriors, but rather, the use of inferior materials on sides which face adjoining property. No portion of a building constructed of unadorned concrete block or corrugated and/or sheet metal may be visible from any public right of way. No building exterior may be constructed of unpainted concrete block or corrugated and/or sheet metal. Mechanical equipment, whether ground-level or rooftop, must be shielded and screened from public view and designed to be perceived as an integral part of the building. Buffers & Screening: The Zoning Ordinance requires that solid waste storage areas (i.e., dumpsters, garbage cans, trash corn pactors, etc.) be screened from view of adjacent property and public rights of way by a solid fence, wall, dense evergreen plantings or architectural feature. In addition, sites must be designed and buildings oriented so that loading areas are screened from any property where loading areas are prohibited and from public rights of way. 4 94SN0199ANP/MAY25L With the approval of this request, outside storage would be permitted. Outside storage areas must be screened from view of adjacent properties which have no such areas and public rights of way. Conclusions: Although the Northern Area Land Use and Transportation Plan designates the property for light industrial use, the proposed General Commercial (C-5) zoning and land uses are representative of area commercial development trends along Hull Street Road. Further, the property is currently zoned for a mix of commercial and industrial uses. Rezoning to General Business (C-5) would allow all C-5 and I-1 uses on the property, subject to the development standards of the Zoning Ordinance which ensure quality development. Therefore, approval of this request is recommended. CASE HISTORY Planning Commission Meeting (4/26/94): The applicant accepted the recommendation. There was no opposition present. On motion of Mr. Easter, seconded by Mr. Cunningham, the Commission recommended approval of this request. AYES: Unanimous. The Board of Supervisors on Wednesday, May 25, 1994, beginning at 7:00 p. m., will take under consideration this request. 5 94SN0199/WP/MAY25L PRICE CLUB ROCKWOOD ~' UARE :::::) I---- ROCKWOOD PARK -5 v v ,4 94SN0199 REZ: Z-I TO SH. 14