18SN0836 CASE NUMBER: 18SN0836 APPLICANT: THALHIMER REALTY PARTNERS CHESTERFIELD COUNTY, VIRGINIA MIDLOTHIAN DISTRICT ANALYSIS AND RECOMMENDATION Board of Supervisors Hearing: DECEMBER 12, 2018 BOS Time Remaining: 365 DAYS : ANDREW CONDLIN (804-977-3373) Planning Department Case Manager: 5.8 Acres 14008 Midlothian Turnpike DARLA ORR (804-717-6533) WINTERFIELD REQUEST Rezoning from Residential (R-7) to Neighborhood Business (C-2) of 2.8 acres and Residential Townhouse (R-TH) of 3 acres plus conditional use planned development to permit exceptions to ordinance requirements on the entire 5.8 acre tract. Specifically, exceptions are requested to use, setbacks, buffers, parking, lot and building standards to accommodate over-shop housing in the C- 2 District and 50 townhomes in the R-TH District. Notes: A. Conditions may be imposed or the property owner may proffer conditions. B. Proffered conditions, Textual Statement, and exhibits are located in Attachments 1-6. SUMMARY A development including a maximum of 50 townhomes and neighborhood commercial uses with up to 15 above shop multi-family residential units is planned. Development will occur as generally depicted on the conceptual plan (Exhibit A, Attachment 4) with townhomes served by alleys, a common green and commercial uses at the corner of Midlothian Turnpike and Winterfield Road. The applicant has proffered design and architectural standards (discussed on pages 6 and 7) to ensure a well-designed, quality development comparable with the surrounding area. The applicant has proffered to realign the existing Winterfield Road roundabout and approaches and install/maintain of landscaping and features within the Winterfield roundabout to off-set the Providing a FIRST CHOICE community through excellence in public service RECOMMENDATIONS PLANNING APPROVAL COMMISSION PLANNING - APPROVAL Proposal provides a mixed-use development suggested appropriate in the Village Fringe area of the Midlothian Area Community Plan Quality design and architecture offered by the applicant provide for a STAFF convenient, attractive and harmonious community that should enhance the surrounding area. TRANSPORTATION - APPROVAL Dproviding road improvements. SUMMARY OF IDENTIFIED ISSUES Department Issue Post 2020, the tǒĬƌźĭ CğĭźƌźƷźĻƭ tƌğƓ recommends a new high school in the vicinity of Genito and Otterdale Roads northwest of Swift Creek Reservoir, SCHOOLS however at this time a budget has not been developed for the acquisition of land or construction of this school facility as recommended in the tƌğƓ. 2 18SN0836-2018DEC12-BOS-RPT 3 18SN0836-2018DEC12-BOS-RPT TABLE A REQUEST PROPERTIES Tax Identification Number Address 725-709-9433 1105 WINTERFIELD RD 725-709-9911 14030 WINTERFIELD LN 726-708-0495 14028 WINTERFIELD LN 726-708-1397 14022 WINTERFIELD LN 726-708-3588 14008 MIDLOTHIAN TPKE 726-709-0149 1109 WINTERFIELD RD 726-709-0434 1101 WINTERFIELD RD 726-709-0813 14024 WINTERFIELD LN 726-709-1718 14018 WINTERFIELD LN 726-709-2430 14012 WINTERFIELD LN 726-709-3003 14010 WINTERFIELD LN 4 18SN0836-2018DEC12-BOS-RPT Comprehensive Plan Midlothian Area Community Plan Classification: VILLAGE RESIDENTIAL AND VILLAGE FRINGE This designation suggests the property is appropriate for mixed use development compatible with surrounding neighborhoods, including office, residential, multi-family, community facilities and personal service uses using special design standards to preserve pedestrian scale. Surrounding Land Uses and Development Winterfield Road Westfield Road Commercial and multi- family residential zoning and land use Single family residential use or vacant Midlothian Tpk 5 18SN0836-2018DEC12-BOS-RPT PLANNING Staff Contact: Darla Orr (804-717-6533) orrd@chesterfield.gov Proposal Rezoning is proposed from Residential (R-7) to Neighborhood Business (C-2) of 2.8 acres and Residential Townhouse (R-TH) of 3 acres, as identified on the zoning map (Page 3), plus conditional use planned development to permit exceptions to ordinance requirements on the entire 5.8 acre tract. A 50-lot townhome development is planned on the portion of the property proposed for rezoning to R-TH, and Neighborhood Commercial (C-2) uses with a maximum of 15 over-shop multi-family residential units are planned on the portion of the property to be zoned C-2. Development would conform to the Conceptual Plan (Exhibit A, Attachment 4). Exceptions are requested to ordinance requirements to accommodate the mixed-use design, as outlined below and in the Textual Statement (Attachment 2): Reduction in setbacks for buildings, parking and drives Modification to permit on-street parking to count towards required spaces; parking for over-shop multi-family residential units shared with commercial uses Modification of R-TH District standards (Schedule 1, Attachment 3) Elimination of the buffer and setbacks between C-2 and R-TH zoning boundary Use exception of permit over-shop multi-family residential units and fast-food restaurant without drive-in or drive-thru Overall Design The following provides an overview of design requirements offered as part of this request (Attachments 1 -6 Proffered Conditions, Textual Statement and exhibits): Community Design Designed in general conformance with the Conceptual Plan (Exhibit A, Attachment 4) o Pedestrian scale decorative exterior lighting along Midlothian Turnpike o Sidewalks and crosswalks throughout development and along adjacent rights of way o Street trees along adjacent rights of way and both sides of internal drive aisles o Minimum of 0.5 acre of open space to serve the townhome and multi-family o residential uses planned; includes central green (Exhibit A, Attachment 4) Wet stormwater management facility designed as a visual amenity including o pedestrian areas and fountain Residential Townhome Design High quality residential development addresses the Comprehensive Plan goals for strong and sustainable neighborhoods that are visually attractive, well-planned and well- maintained. Further, the purpose and intent of the zoning ordinance to promote the health, safety, convenience and general welfare of the public includes the creation of convenient, attractive and harmonious communities, protection against overcrowding of land, and protection of the natural environment. As such, developments that promote unique, viable and long-lasting places and enhance the community are encouraged. 6 18SN0836-2018DEC12-BOS-RPT The following provides an overview of R-TH design requirements offered as part of this request (Attachments 1- 4 and 6) Proffered Conditions, Textual Statement, Schedule 1, and Exhibits A and C): Lots Maximum of 50 townhomes permitted o o Sodded front and corner side yards and foundation planting beds o All units served by alleys o Buildings and Architecture Architectural treatment comparable to Exhibit C (Attachment 6) o Exterior facades constructed of brick, stone or cultured stone and cementitious o siding or comparable materials approved by Planning; no vinyl Variety of frontal elevations, roof lines and setbacks to maintain visual interest o along the streetscape Up to 12 attached townhomes in a group; Maximum of 3.5 stories or 41 feet o Foundations of brick or stone extending a minimum of 18 inches above grade for o units constructed on slab; raised front façade porches (minimum finished floor elevation of 15 inches above grade); porch foundations and exposed piers faced with brick or stone 30-year roof materials (standing seam, architectural dimensional shingle or o better) No front-loaded garages; all garages served by alleys o Screening of mechanical equipment o Commercial Design Development of commercial uses will comply with Midlothian Special Design District standards, except as outlined in the Textual Statement. In addition, the following design standards have been offered as part of this request. Attachments 1 2 and 4 5) Proffered Conditions, Textual Statement and Exhibits A and B): Maximum 45,000 square feet of commercial space; No individual tenant size shall exceed 15,000 square feet of gross floor area Buildings located with no parking between or drives between buildings and public roads Architectural treatment of buildings comparable to Exhibit B (Attachment 5) Buildings to incorporate 4-sided equal architectural treatment; maximum height of 3 stories Buildings constructed of brick, stone, cultured stone or cementitious siding or comparable materials as approved by Planning No loading docks permitted; no service doors facing Midlothian Turnpike or Winterfield Road unless screened As suggested by the Comprehensive Plan goals and the Zoning Ordinance, the proffered conditions offered with this request include quality design and architectural elements comparable to that of the surrounding community. 7 18SN0836-2018DEC12-BOS-RPT BUDGET & MANAGEMENT Staff Contact: Natalie Spillman (804-318-8767) spillmann@chesterfield.gov County finance staff is responsible for managing the finances of the County and making recommendations to the County Administrator regarding the allocation of available resources for the provision of services and capital facilities to serve the citizens of the County. Finance staff will advise the County Administrator if changed economic circumstances require COUNTY TRANSPORTATION Staff Contact: Steve Adams (804-748-1037) adamsSt@chesterfield.gov The applicant has committed to a maximum commercial and residential development (Proffered Condition 15 and 17, and Textual Statement III.A.). Based on the trip generation rates for the maximum development density (50 townhome units, 15 multi-family units, and 45,000 square feet of retail/shopping center), the proposed development could generate approximately 3,850 average daily trips. Traffic generated by development of the property will be initially distributed along Winterfield Road to Midlothian Turnpike (Route 60). Winterfield Road is a collector road with a recommended right of way width of 70 feet, as ŷƚƩƚǒŭŷŅğƩĻ tƌğƓ. Winterfield Road is a two-lane road. Sections of the road have been improved and realigned in conjunction with residential development. maintained in its existing condition. Midlothian Turnpike (Route 60) is identified ŷƚƩƚǒŭŷŅğƩĻ tƌğƓ as a major arterial with a recommended right of way width of 120 to 200 feet. Midlothian Turnpike is a four-lane divided roadway. In 2015, the traffic count on Midlothian Turnpike between Route 288 and Winterfield Road was Section 19.1-231 of the County Code outlines the general requirements to meet the needs of the traffic generated by a proposed development, including acceptable levels of service. The proposed mixed-use development would contribute to an identifiable need for transportation and access improvements. The applicant has offered: Right-of-Way Dedications (Proffered Condition 9): Sixty (60) foot right-of-way for an East West Local Road through the property. Thirty-five (35) foot right-of-way from the centerline of Winterfield Road. Vehicular Access Control (Proffered Condition 10): Limited to two (2) entrances/exits to Winterfield Road. No direct access to Route 60. Road Improvements (Proffered Condition 11): Construction of two lanes for the East West Local Road through the property. (a) Separate right turn lane along Winterfield Road to serve the south access. (b) 8 18SN0836-2018DEC12-BOS-RPT Raised median within Winterfield Road to preclude left turns at the south access. (c) Sidewalks along Route 60, Winterfield Road, and the East West Local Road. (d) Abandon and removal of existing Winterfield Lane on the property. (e) Construction of cul-de-sac or turnaround at new terminus of Winterfield Lane. (f) Realignment of the existing Winterfield Road roundabout and approaches. (g) Installation/maintenance of landscaping & features within the Winterfield roundabout. (h) The property is within Traffic Shed 2, which encompasses the northwest area of the County, west of Huguenot Road and north of Midlothian Turnpike. Several roads in this part of the county have little or no shoulders, fixed objects (trees) adjacent to the edge of the pavement and poor vertical and horizontal alignments. The traffic volume generated from this proposed mixed-use development will contribute to an identifiable need for transportation facility improvements to these roads in excess of existing transportation facility capacity. Roads in this shed or which serve this shed need to be improved or widened to address safety and accommodate increased traffic, including the increased traffic from the proposed development. network through dedication of property, construction of road improvements, or a cash proffer. If an applicant elects to offer cash to address the proposed residential transportation network, Transportation staff has calculated the average impact of a single-family dwelling unit on the transportation network to be $12,652; however, the Board of Supervisors has adopted a policy establishing that it would accept a maximum cash proffer of $9,400 per dwelling unit as addressing the traffic impacts of residential development, with all of the funds to be dedicated towards improvements to the road network. The Policy allows the county to consider mitigating circumstances about a proposed development. In this case, the residential development is limited to townhome and multi-family (apartment/condominium) uses, which generate approximately 63% and 60% of the traffic of single-family dwelling units, respectively. Because of this, the traffic impact could be addressed with $5,922 (63% of $9,400) per townhome dwelling unit and $5,640 (60% of $9,400) per multi-family dwelling unit. The traffic impact of the proposed development could be valued at $380,700 (50 x $5,922 + 15 x $5,640). As previously noted, the applicant has proffered to construct specific off-site road improvements along Winterfield Road (Proffered Conditions 11.g and 11.h). The condition requires the applicant to complete all road improvements prior to issuance of an occupancy permit. The applicant has provided information that the estimated cost of the off-site road improvements is $396,000 however, that the actual cost to provide these improvements could be more or less than this amount. Staff supports this request. FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Mission The mission of Fire and Emergency Medical Services (EMS) is to protect life, property and the environment through a comprehensive fire and life safety program that ensures an adequate and timely response to emergencies. 9 18SN0836-2018DEC12-BOS-RPT Response Times The proposed development is located in the urban response zone for which Fire & EMS has a goal of responding to at least 90% of the calls for service in under seven (7) minutes. Fire and EMS is currently unable to meet that goal. Nearby Fire and Emergency Medical Service (EMS) Facilities Fire Station The Midlothian Fire Station, Company Number 5 EMS Facility The Forest View Volunteer Rescue Squad Anticipated Fire & EMS Impacts/Needs Based on an average of .175 calls per dwelling, it is estimated that this development will generate 11 annual calls for Fire/EMS services. Additional Fire and EMS Comments When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. SCHOOLS Staff Contact: Atonja Allen (804-318-8740) atonja_allen@ccpsnet.net Mission High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater access, flexible designs and locations that better meet the needs of the communities in which they are located. Capital Improvements The School Board FY2019 adopted Capital Improvement Plan (CIP) continues to support the 2013 voter approved school revitalization program that will replace or renovate ten schools and construct one new elementary school to add capacity in the Midlothian area of the county. The ten existing facilities that are part of the revitalization program are Beulah Elementary School, Crestwood Elementary School, Enon Elementary School, Ettrick Elementary School, Harrowgate Elementary School, Matoaca Elementary School, Reams Elementary School, Manchester Middle School, Providence Middle School, and Monacan High School. A replacement Enon Elementary School is currently in construction on the existing school site, a replacement Manchester Middle School is planned for construction on the existing school site, and the Beulah Elementary School, Providence Middle School, and Monacan High School projects are complete. Additional school construction projects include a Matoaca Middle School addition on the east campus site, and the new Matoaca Elementary School will be constructed on the existing west campus site. Upon completion of the east campus addition, the current west campus building will be demolished, and Matoaca Middle School will operate as a single, unified campus. Information on the CIP and School Board approved construction projects can be found in the financial section of the CCPS Adopted Budget for FY2019. 10 18SN0836-2018DEC12-BOS-RPT Anticipated School Impacts Elementary Middle High Total (1) Anticipated Student Yield by 10 6 7 23 School Type Schools Currently Serving Area Watkins Midlothian Midlothian 1,230 1,328 1,629 Current Enrollment 2017-18 Design Capacity (2) 1,022 1,400 2,155 School Year 120% 95% 76% Enrollment Percent of Design Capacity 24 3 0 Total Number of Trailers Number of Classroom Trailers 23 0 0 Note: Based upon average number of students per townhome dwelling unit countywide at 0.35 and average number of (1) students per multifamily dwelling unit countywide at 0.34. Student Generation Factor (2017) is the actual total number of students by grade level divided by the actual total number of housing units by housing type. Design capacity is the maximum number of students the building can accommodate based on the Virginia Department (2) of Education Standards of Quality and the architectural program design of the existing building including all interior and exterior renovations to date and an inventory of all available space. Design capacity does not include site-based initiatives and is thus not subject to frequent change and represents prototypical design capacity using VDOE standards. Public Facilities Plan The tǒĬƌźĭ CğĭźƌźƷźĻƭ tƌğƓ recommends a new elementary school be located in the vicinity of Old Hundred and Otterdale Roads, north of Genito Road and south of Midlothian Turnpike. In October 2016 the Board of Supervisors approved Case 17PD0105 for substantial accord to permit an elementary school located at 1501 Old Hundred Road, and the school division has acquired this property and construction is in progress. Post 2020, the tƌğƓ also recommends a new high school in the vicinity of Genito and Otterdale Roads northwest of Swift Creek Reservoir, however at this time a budget has not been developed for the acquisition of land or construction of this school facility as recommended in the tƌğƓ. UTILITIES Staff Contact: Mike Larson (748-1338) larsonm@chesterfield.gov Existing Water and Wastewater Systems Currently Size of Closest Existing Connection Required by County Utility Type Serviced? Lines Code? Water Yes 12, 24 Yes Wastewater Yes 8 Yes The property is located in the mandatory water and wastewater connection area for residential and non-residential development per Sections 18-60 A and B of the County Code. Public water is available through a 12- 11 18SN0836-2018DEC12-BOS-RPT Winterfield Ln. Any new structure(s) proposed for the site would be required to use the public water and wastewater system. The applicant is reminded of the Utilities Department Standards to provide a second water feed for residential developments with more than 25 lots. The Utilities Department will also require that the Developer design and construct the water and wastewater lines, properly sized and at an appropriate location, to permit future extensions to the east of this development. The applicant has proffered the use of public water and wastewater (Proffered Condition 8). The Utilities Department supports this case. 12 18SN0836-2018DEC12-BOS-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) WardR@chesterfield.gov Geography The subject properties generally drain form northeast to southwest to an existing culvert under Winterfield Road and into the existing pond within the Midlothian Town Center development. The properties are all located within the James River Watershed. Environmental Features A Resource Protection Area Designation (RPAD) must be submitted to and confirmed by the Environmental Engineering Water Quality Section prior to the approval of any site plans, preliminary plats, and/or construction plans. Any areas of wetlands shall not be impacted without prior approval from the U.S. Army Corps of Engineers and/or the Virginia Department of Environmental Quality. Stormwater Management The development of the subject properties will be subject to the Part IIB technical criteria of the VSMP Regulations for water quality and quantity. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Jonathan Phillippe (804-674-2560) jonathan.phillippe@vdot.virginia.gov LIBRARIES Staff Contact: Jennifer Stevens (804-751-4998) stevensj@chesterfield.gov PARKS AND RECREATION Staff Contact: Stuart Connock (804-751-4484) ConnockS@chesterfield.gov To date, no comments have been received. 13 18SN0836-2018DEC12-BOS-RPT CASE HISTORY Applicant Submittals 6/8/18 Application submitted 10/9 and Application amended 11/13/18 8/16, 8/21, Revisions to Proffered Conditions, Textual Statement and exhibits submitted 9/13, 10/10, 10/11, 10/12, 10/15, 10/18, 10/31, 11/7, 11/9 and 11/13/18 Community Meeting 10/15/18 Issues Discussed: Overall development design and architecture Area traffic impacts and concerns; road improvements to be made with development Roundabout on Winterfield not designed well; Potential in this case to improve roundabout design Planning Commission 1/20/18 Citizen Comments: Development in village impacts Westfield Road community; history of area Important to engage Westfield area as developments and Plan proposed Buffers as transition to single family residential use Support for architecture and design ld Road community but will meet did participate in community meeting Commission Discussion: Mr. Jones noted he agrees that the historic importance of the Westfield Road community is important to area. He added that the proposed owner-occupied townhomes would be compatible with residential use east of Winterfield Road. Recommendation APPROVAL AND ACCEPTANCE OF THE PROFFERED CONDITIONS IN ATTACHMENT 1 Motion: Jones Second: Jackson AYES: Sloan, Jackson, Freye, Jones and Stariha The Board of Supervisors on Wednesday, December 12, 2018, beginning at 6:00 p.m., will consider this request. 14 18SN0836-2018DEC12-BOS-RPT ATTACHMENT 1 PROFFERED CONDITIONS November 13, 2018 Note: The Planning Commission and staff recommend acceptance of the following proffered conditions, as offered by the applicant. The Owner-Applicant in this rezoning Case 18SN0836, pursuant to Section 15.2-2298 of the Code of Virginia (1950 as amended) and the Zoning Ordinance of Chesterfield County, Virginia, for itself and its successor or assigns, proffers that the development of the Property will be developed as set forth below; however, in the event the request is denied or approved with conditions not agreed to by the Owner-Applicant, these proffers shall be immediately null and void and of no further force or effect. The following proffers shall apply to the entirety of the Property: Master Plan. The Textual Statement last revised November 13, 2018, shall be considered 1. the Master Plan. (P) Concept Plan Requirements. The site shall be designed as generally depicted on 2. and parking areas may be modified provided that the general intent of the Concept Plan is maintained with respect to location of uses, internal road network and pedestrian environment. (P) Common Area. The common area shown on the Concept Plan in the center of the 3. Property shall serve as a focal point upon entry into the Property and shall serve both the residential and commercial portions of the Property. The common area shall include public spaces designed to include amenities that add high visual interest, such as, but not limited to: hardscaped areas; decorative paving units; decorative pedestrian-style lighting; benches; landscaped areas; plantings; bike racks; plazas; gathering areas; and other similar pedestrian elements. (P) Street Lights. Decorative goose neck street lights will be provided along the Property 4. boundary as it adjoins Midlothian Turnpike with a spacing of approximately 80 feet on center. The specific light fixture and spacing shall be approved by the Planning Director in conjunction with plan approval. The installation of the street lights may be phased as approved by the Planning Director based on the extent of the plan approval. (P) Street Trees. Street trees shall be provided along Midlothian Turnpike and Winterfield 5. Road along the entire property frontage at a minimum of 40 feet on center unless there are conflicts with utilities, sightlines, and/or driveway areas and as otherwise 15 18SN0836-2018DEC12-BOS-RPT approved by the Planning Director at time of plan approval. Street trees shall also be provided within the site along both sides of drive aisles (not including alleys) planted every 40 feet on center unless there are conflicts with utilities, sightlines, and/or driveway areas and as otherwise approved by the Planning Director at time of plan approval. (P) Sidewalks. There shall be an internal system of sidewalks and crosswalks within the 6. development to provide pedestrian connections within the site and to the sidewalks provided along the adjoining roads. Sidewalk connections to adjoining properties shall be made along the East West Local Road, as hereinafter defined, and near the terminus of Winterfield Lane. The design, materials and exact location of such sidewalks and crosswalks shall be approved by the Planning Director at the time of plan review. (P) Burning ban. The Developer shall not use burning to clear or timber the Property. (F) 7. Utilities. Public water and wastewater systems shall be used. (U) 8. Dedication. The following rights-of-way on the Property shall be dedicated, free and 9. unrestricted, to Chesterfield County prior to any site plan approval, in conjunction with the recordation of the initial subdivision plat, or within sixty (60) days of a written request by the Transportation Department, whichever occurs first. a.A sixty (60) foot wide right-of- line or in an alternative location acceptable to the Transportation Department. The exact location of this right-of-way shall be approved by the Transportation Department. b.Thirty-five (35) feet of right-of-way, on the east side of Winterfield Road, measured from the centerline of that part of Winterfield Road immediately adjacent to the Property. (T) Access. Access to and from the Property shall be as follows: 10. a.Direct vehicular access from the Property to Winterfield Road shall be limited to the East--West Local -turns-in and right-turns-out only Transportation Department. b.There shall be no direct vehicular access from the Property to Midlothian Turnpike (Route 60). (T) 16 18SN0836-2018DEC12-BOS-RPT Road Improvements. Prior to issuance of an occupancy permit on the Property, the 11. developer shall be responsible for the following road improvements. The exact design and length of the improvements shall be approved by the Transportation Department: a.Construction of two lanes of the East West Local Road, to VDOT Urban Local Road standards, with modifications approved by the Transportation Department, from Winterfield Road to the eastern property line. The exact location of the East West Local Road shall be approved by the Transportation Department. b.Construction of additional pavement along the northbound lanes of Winterfield Road at the approved South Access to provide a separate right turn lane. c.Construction of a raised median within Winterfield Road from the Winterfield Road roundabout to just south of the South Access to preclude left turns at the South Access. d.Construction of VDOT standard sidewalks along the entire property frontage to Route 60, Winterfield Road, and the East West Local Road. e.Abandonment and removal of existing Winterfield Lane on the property, if approved by VDOT and the Transportation Department. f.Construction of a cul-de-sac or other acceptable turnaround or other treatment approved by VDOT, at the proposed terminus of Winterfield Lane on the Property towards the eastern Property line, with modification approved by the Transportation Department. g.Realignment of the existing Winterfield Road roundabout and approaches to provide symmetric alignment with Winterfield Road. h.Installation and maintenance of landscaping and ornamental features within the Winterfield Road roundabout, as determined by the Transportation Department and as approved by the Virginia Department of Transportation. i.Dedication to Chesterfield County, free and unrestricted, of any additional right- of-way (or easements) required for the improvements identified above. (T) The following proffers shall apply to the area of the Property zoned C-2: Architecture. Buildings shall be generally compatible with respect to building materials 12. and architectural style with the elevations attached hereto as Exhibit B and dated October 5, 2018. All buildings shall have exterior wall surfaces constructed of brick, stone or cultured stone, and cementitious siding, exclusive of windows, doors, cornices, and accent treatments, or other comparable or better materials as approved by the Director of Planning. All buildings shall incorporate equal four sided architecture such that no building exterior (whether front, side or rear) shall consist of inferior materials or be inferior in quality, appearance or detail to any other exterior of the same building. No loading docks shall be permitted. No service doors shall face Midlothian Turnpike or Winterfield Road unless they are screened from view of public roads by landscaping, or low maintenance material, such as an opaque fence or wall, as approved by the 17 18SN0836-2018DEC12-BOS-RPT Planning Director. (P and BI) Building Height. Buildings shall be limited to a maximum of three stories in height. (P 13. and BI) Building Location. Buildings shall be generally located such that no parking or drives 14. are between the buildings and Midlothian Turnpike and Winterfield Road; however, the location of the buildings, parking and drives may be modified as approved by the Planning Director at the time of plan approval. (P) Density. No more than 45,000 total square foot of commercial space shall be permitted 15. on the area of the Property zoned C-2. No individual tenant shall exceed 15,000 square feet of gross floor area. (P and BI) Water Features. Any wet stormwater management facility shall be designed as a visual 16. amenity to create water features, which shall include pedestrian areas and fountain type aerators, unless specifically prohibited or restricted by law or government regulation, and as determined by Environmental Engineering. Any commercial building adjoining any such water feature shall include at least one entrance for a customer or guest access point facing such water feature, which shall be permitted to be a secured or unsecured patio or dining area. (P and EE) The following proffers shall apply to the area of the Property zoned R-TH: Density. No more than 50 townhouse dwelling units shall be permitted on the area of 17. the Property zoned R-TH. (P) Front Walks. A minimum of a 42-inch-wide concrete front walk shall be provided to the 18. front entrance of each townhouse unit, to connect to drives, sidewalks or streets. (P) Landscaping: 19. a.Except for foundation planting beds, front and corner side yards shall be sodded and irrigated. b.Foundation planting is required along the entire front façade of all townhouse units, and shall extend along all sides facing a street. Foundation planting beds shall be a minimum of 3 feet wide from the dwelling foundation. Planting beds shall be defined with a trenched edge or suitable landscape edging material. Planting beds shall include medium shrubs, spaced a maximum of four (4) feet apart, and may include spreading groundcovers. Dwelling corners shall be 18 18SN0836-2018DEC12-BOS-RPT -n height at the time of planting). Planting bed deviations may be approved by the Planning Director at time of plan review due to unique design circumstances. (P) Architecture and Materials: 20. a.Townhouse units shall be generally compatible with respect to building materials and architectural style with the elevations shown on the rendering attached hereto as Exhibit C and dated October 5, 2018. All buildings shall have exterior wall surfaces constructed of brick, stone or cultured stone, and cementitious siding, exclusive of windows, doors, cornices, and accent treatments, or other comparable or better materials as approved by the Director of Planning. b.Townhouse units with the same elevations and color palette may not be located adjoining to or directly across from each other on the same street or access road. In either case, this requirement does not apply to dwellings on different streets or access roads backing up to each other. c.If the townhouse unit is constructed on a slab, brick or stone shall be employed around the base of the dwelling a minimum eighteen (18) inches above grade as to give the appearance of a foundation. Front façade porches shall have a minimum finished floor elevation of not less than 15 inches above grade at the - line. All exposed portions of the foundation and exposed piers supporting front porches of each townhouse unit shall be faced with brick or stone veneer. d.Rooflines for each townhouse unit shall vary from adjoining, connected dwellings. Roofing materials for townhouse units shall be standing steam metal or dimensional architectural shingles or better with a minimum 30-year warranty. (P and BI) Heating, Ventilation and Air Conditioning (HVAC) Units and Generators. Heating, 21. ventilation and air conditioning (HVAC) units and generators shall be screened from view of public roads by landscaping, or low maintenance material, such as an opaque fence or wall, or parapet wall, all as approved by the Planning Director. (P) Alley Access. All garages for townhouse units shall be served by an alley, as generally 22. shown on the Concept Plan, unless otherwise approved by the Planning Director at the time of plan review. (P) 19 18SN0836-2018DEC12-BOS-RPT ATTACHMENT 2 TEXTUAL STATEMENT Last Revised November 13, 2018 Re: Request to rezone property to C-2 and R-TH with a Conditional use Planned Development. The development is intended to create a mixed use community containing commercial uses fronting on Midlothian Turnpike with for sale single family attached townhomes providing a transition to the single family detached homes along Winterfield Road. The design of the development will include road improvements to provide connection to Winterfield Road and properties to the east of the site. Development of the Property shall comply with the Zoning Ordinance requirements except as outlined herein. I.General Requirements: A.Parking. i.Parking for all uses within the C-2 zoned area of the Property (the minimum of four (4) spaces per one thousand (1,000) square feet of rentable commercial space. Parking for all dwelling units on the RTH zoned area of the Property shall be required to have on the Property a minimum of two (2) spaces for each dwelling unit, which may include those spaces located in a garage and in the driveway. No parking is required for any dwelling unit in the C-2 zoned area of the Property. Parking along the east/west local road from Winterfield Road through the property to the eastern property line may be counted toward the parking required herein. ii.Parking spaces shall be provided pursuant to the provisions of I(A)(i) above based on the collective sum of the calculation of each such use. Such parking must be provided within the development as a whole but shall not be required on each parcel/site or within any particular area of the Property. Parking along any street or drive aisle within the project shall be counted towards the required parking. Through plan review, a reduction in the required number of spaces may be granted if it is determined by the Planning Department that uses will have different time demands, or sidewalks or pedestrian ways will be provided between uses. B.Buffer. No buffer shall be required between the C-2 and R-TH zoned portions of the Property. Providing a FIRST CHOICE community through excellence in public service II.R-TH Standards: A.Table 19-111. Development of the portion of the R-TH portion of the Property shall comply with the R-TH Zoning Ordinance with the exception of Table 19.1-111 of the County Zoning Ordinance, which shall be replaced with the attached Schedule 1, dated November 9, 2018. III.Commercial Standards: A.Uses. Uses shall be permitted as follows: i.Uses permitted by right or with restrictions in the Neighborhood Business (C-2) Districts, except the following uses shall be prohibited: a.Automobile sales and rental, including consignment lots b.Automobile service stations c.Automobile wash d.Check cashing e.Flea markets f.Funeral homes g.Gasoline sales h.Halfway Houses i.Hospitals j.Kennels, commercial k.Mortuary l.Motorcycle, Go Cart, All-Terrain Vehicle, or similar type vehicle track or operation m.Pawnbroker n.Veterinary hospital with outside runs o.Video rental and sales store p.Worship, place of ii.Fast food restaurants, except there shall be no restaurant drive in or drive thru permitted. iii.Multiple-family dwelling units shall be permitted provided that any such dwelling units are located above the first floor and no more than 15 dwelling units shall be permitted. 2118SN0836-2018NOV20-CPC-RPT B.Setbacks. Structures, parking areas, drive aisles and access roads shall not have any setback requirements from interior property lines or the eastern (rear) property line. 2218SN0836-2018NOV20-CPC-RPT ATTACHMENT 3 Schedule 1 November 9, 2018 DIVISION 11. R-TH RESIDENTIAL TOWNHOUSE DISTRICT Sec. 19.1-110. Purpose and Intent of R-TH District. Reserved. Sec. 19.1-111. Required Conditions R-TH District for Subdivision Recorded on or after 11/13/1985 and Which Did Not Have Valid Preliminary Plat Originally Approved Prior to 11/13/1985. . A.Subdivision Standards Table 19.1-111. A. Required Conditions R-TH District-Subdivision Standards Notes for Table 19.1-111. A. \[1\] A. Subdivision Size 2.5 acres \[1\]Minimum acreage requirements do B. Density 50 dwelling units not apply to the Enon and Chester C. Private Pavement Setbacks Special Design Districts. 1. Major arterial 20 feet \[2\]Within required common area, except 2. Other road 5 feet where lots abut a public street, a 5 foot wide common area shall be 20% of subdivision \[2\]\[3\] D. Common Area provided around the perimeter of each acreage group of attached lots. E. Maximum Number of Attached Lots 12 \[4\] in Each Group \[3\]Within the common area of the project, a minimum of .5 acres shall be provided for passive and active recreational use and community space, including pedestrian areas, the central common area shown on the Concept Plan and other uses deemed appropriate during plan review. Unless a phasing plan is approved through preliminary plat review, construction shall be completed prior to issuance of building permits for individual townhouse units. An approved phasing plan may include limitations on the issuance of building permits for individual townhouse units. \[4\]The number of lots in each group of attached lots shall be varied throughout the subdivision. 2318SN0836-2018NOV20-CPC-RPT B.Other Required Subdivision Standards. 1.Common Areas Ownership. Areas which are not contained in roads or in lots that are conveyed to individual owners shall be maintained by, and be the sole responsibility of, the developer and/or owner of the townhouse development, unless and until the developer and/or owner conveys such areas to a nonprofit corporate owner, whose members shall be all of the individual owners of townhouses in the development, or to a nonprofit council of co-owners as provided under the Code of Virginia. The land shall be conveyed to, and be held by, the nonprofit corporate owner or the nonprofit council of co-owners and used for the recreational and parking purposes of the individual townhouse lot owners. If the developer and/or owner makes the conveyance to a nonprofit corporate owner, deed restrictions and covenants, in a form and substance satisfactory to the county attorney, shall provide, among other things, that any assessments, charges and costs of the maintenance of such areas shall constitute a pro rata lien against the individual townhouse lots, inferior in dignity only to taxes and bona fide duly recorded deeds of trust on each townhouse lot. An applicant seeking to subject property to townhouse development under this section whose ownership or interest in the property is held by a valid lease, shall provide for an initial term of not less than 99 years in such lease. 2.Roads and Private Pavement. All roads and private pavement shall have concrete curb and gutter, except for alley access roads that access the rear of the dwelling unit. 3.Architecture. Buildings shall be designed to impart harmonious proportions and avoid monotonous facades or large bulky masses. Townhouse buildings shall possess architectural variety while at the same time have an overall cohesive residential character. Residential character may be achieved through the creative use of design elements such as, but not limited to, balconies, terraces, articulation of doors and windows, sculptural or textural relief of facades, architectural ornamentation, varied rooflines, or other appurtenances such as lighting fixtures and planting. 4.Architectural and Landscaping Plans. In conjunction with construction plan submission, landscape and architectural renderings or elevations shall be submitted for approval. 2418SN0836-2018NOV20-CPC-RPT . C.Lot and Building Standards Table 19.1-111.C. Required Conditions R-TH District- Lot and Building Standards A. Lot Standards 1. Lot area (square feet) a. Internal lot 1040 b. End lot in row of less than 5 attached lots 1040 c. End lot in row of 5 or more attached lots 1040 2. Lot width (feet) a. Internal lot 16 b. End lot in row of less than 5 attached lots 16 c. End lot in row of 5 or more attached lots 16 3. Lot coverage (maximum %) 65 B. Road Frontage for Townhouse Units \[1\] C. Principal Building Setbacks (feet) \[2\] 1. Major arterial all yards 20 2. Front yard \[3\]\[4\] a. Non cul-de-sac 10 b. Permanent cul-de-sac 10 3. Side yard a. End unit in a row of less than 5 attached lots 5 b. End unit in a row of 5 or more attached lots 5 4. Corner side yard 5 5. Rear yard a. Non through lot 5 b. Through lot 5 D. Principal Building Height (maximum) \[5\] 1. Midlothian Core and Lesser of 3.5 stories or 41 feet Chester Corridor East Special Design Districts 2. Other Lesser of 3 stories or 40 feet E. Accessory Building Requirements Subject to Section 19.1-304 Notes for Table 19.1-111.C. \[1\]All lots shall have frontage on a road. If approved by the director of transportation, lots may front on private pavement which has direct access to a public road when the private pavement is designed and constructed in accordance with the provisions of Chapter 17 for alleys and private pavement. \[2\]Setbacks may be impacted by Buffer, Setbacks --Generally, Permitted Yard Encroachments for Principal Buildings, Floodplain, Chesapeake Bay or Upper Swift Creek Watershed regulations. \[3\]Minimum setbacks shall be increased where necessary to obtain the required lot width at the front building line. \[4\]The front yard setback of each unit shall be varied at least 2 feet from the adjacent unit and every third unit shall be varied at least 4 feet from the adjacent unit. \[5\]Height limits are subject to Article IV, Division 2. 2518SN0836-2018NOV20-CPC-RPT ATTACHMENT 4 EXHIBIT A Conceptual Plan 2618SN0836-2018NOV20-CPC-RPT ATTACHMENT 5 EXHIBIT B Commercial Elevations 2718SN0836-2018NOV20-CPC-RPT 2818SN0836-2018NOV20-CPC-RPT ATTACHMENT 6 EXHIBIT C RESIDENTIAL ELEVATIONS 2918SN0836-2018NOV20-CPC-RPT 3018SN0836-2018NOV20-CPC-RPT