Loading...
19SN0579 CASE NUMBER: 19SN0579 APPLICANTS: Chesterfield County Board of Supervisors CHESTERFIELD COUNTY, VIRGINIA MATOACA DISTRICT AND RECOMMENDATION Board of Supervisors (BOS) Hearing: March 13, 2019 BOSTime Remaining: 365 DAYS : ANDREW GILLIES (804-748-1395) Planning Department Case Manager: 22.8 Acres 20910 Chesterfield Avenue DREW NOXON (804-796-7122) ETTRICK ELEMENTARY SCHOOL, FIRE STATION AND NEIGHBORHOOD PARK REQUEST Rezoning from Neighborhood Business (C-2) to Corporate Office (O-2) on 5.6 acres including 1 acre of public rights-of-way, Community Business (C-3) to Corporate Office (O-2) on 2.2 acres, Residential (R-7) to Corporate Office (O-2) on 15.0 acres plus Conditional Use Planned Development for exceptions to Ordinance requirements on the overall 22.8 acres to permit a fire station, an elementary school, and a neighborhood park. Notes: A.Conditions may be imposed or the property owner may proffer conditions. B.Conditions, Textual Statement and Exhibits are located in Attachments 1 5. SUMMARY An elementary school, fire station and neighborhood park are planned. The proposal would provide for the replacement of Ettrick Elementary School, relocation of Ettrick Fire Station #12, and a new neighborhood park. Exceptions to Ordinance requirements (Ettrick Special Design District standards) are requested to permit adjustments to building setbacks, height, square-footage and design standards; parking setbacks; and signage to accommodate the collocation of multiple public facilities. Providing a FIRST CHOICE community through excellence in public service RECOMMENDATIONS APPROVAL PLANNING COMMISSION APPROVAL Provides replacement of existing fire station and school as recommended by the Public Facilities Plan STAFF Addresses demand issues and delivery of service for Fire Department Provides flexibility of development standards to accommodate collocation of multiple public facilities in accordance with the Plan As conditioned, minimizes impacts on area development 219SN0579-2019MAR13-BOS-RPT SUMMARY OF IDENTIFIED ISSUES Department Issue The Public Facilities Plan identifies the need for a regional park facility of 200 PARKS acres, nearest this location. Land for this park has not been acquired. 319SN0579-2019MAR13-BOS-RPT 419SN0579-2019MAR13-BOS-RPT TABLE A REQUEST PROPERTIES Tax Identification Number Address 794-611-4639 21004 RUTLEDGE AVE 794-611-7377 20910 CHESTERFIELD AVE 794-612-2305 20800 CHESTERFIELD AVE 794-612-4716 20808 CHESTERFIELD AVE 794-612-5726 20810 CHESTERFIELD AVE 794-612-6226 20816 CHESTERFIELD AVE 794-612-6824 20818 CHESTERFIELD AVE 794-612-7324 20820 CHESTERFIELD AVE 794-612-7923 20822 CHESTERFIELD AVE 794-612-8422 20824 CHESTERFIELD AVE 794-612-8920 20826 CHESTERFIELD AVE 794-612-9419 20828 CHESTERFIELD AVE 795-612-0314 20910 JAMES ST 795-612-0725 20830 CHESTERFIELD AVE 795-612-1322 20834 CHESTERFIELD AVE 519SN0579-2019MAR13-BOS-RPT Comprehensive Plan (Ettrick VSU Special Area Plan) Classification: RESIDENTIAL MIXED USE AND SUBURBAN RESIDENTIAL II The designation suggests portions of the property are appropriate for an integrated mixture of higher density residential and concentrated commercial uses and for residential use with a maximum of 2.0 to 4.0 dwelling units per acre. Surrounding Land Uses and Development River Rd. Granger St. Virginia State University (VSU) River Rd. Existing Elementary School Chesterfield Ave. Existing Fire Vacant - Zoned Station #12 Paine St. industrial American Legion Single-family use -Orange Hill 619SN0579-2019MAR13-BOS-RPT PLANNING Staff Contact: Drew Noxon (804-796-7122) noxona@chesterfield.gov Proposal Development of the site for a public elementary school, fire and EMS station and a public neighborhood park is planned as detailed below. Replacement of Ettrick Elementary School: The existing Ettrick Elementary School will be replaced with a new facility containing approximately 100,000 gross square feet. Located to the west of the existing facility, the new school will provide a necessary replacement of an obsolete building constructed in 1967. The Public Facilities Plan recommends revitalization/replacement of the school between 2014 and 2020. Relocation/Replacement of Ettrick Fire Station #12: The Ettrick Fire/EMS Station #12 will be relocated from its current site at 21200 Chesterfield Avenue to a portion of the subject property adjacent to the intersection of Chesterfield Avenue, Granger Street and River Road. This facility would contain approximately 16,000 gross square feet. The Fire Department suggests the site is needed to better meet the growing needs in the Ettrick community and provide a necessary replacement for the existing station built in 1929. According to the Public Facilities Plan, thecurrent Ettrick Fire Station #12 is not adequate to the service demands and physical requirements of a professional station. The Plan recommends construction of a new facility in the same general area. New Neighborhood/Urban Park: A neighborhood/urban park containing approximately 0.75 acre is planned at the intersection of Chesterfield Avenue and Paine Street. The park would include pedestrian amenities and provide for a public gathering place in front of the school. Additional facilities would include a walking trail on the school and fire station sites. While the Public Facilities Plan does not specify an immediate need for a Neighborhood Park in the vicinity, the Plan recommends that Neighborhood Parks supplement community and regional parks in underserved areas. Urban Parks are recommended in high-intensity areas where sufficient park acreage is difficult to acquire and can be developed as hardscaped plazas, open space, spaces between buildings and buffer areas. The proposal would provide parkland in a residential area of Ettrick where no such facilities exist and encourage shared use of public facilities as recommended by the Plan. Rezoning to Corporate Office (O-2) is proposed to permit the collocation of the above-mentioned public facilities, as recommended by the Plan, on one site under uniform development standards. The chart on the following page provides an overview of the proposal and conditions recommended to mitigate the impact of these facilities on surrounding properties (Attachment 1). 719SN0579-2019MAR13-BOS-RPT General Overview Requirements Details Limited to Fire and EMS station, public elementary school and neighborhood/urban park to include walking trails throughout entire Uses site Condition 1 Located on site as generally shown on concept plans Buildings Condition 3 and Exhibits A, B, C & D Along Chesterfield Avenue and Paine Street Sidewalks Condition 4 Minimum 4-foot tall fence containing brick columns and ornamental metal fencing Located between school parking areas and Chesterfield Fencing Ave./Paine St., and between school parking areas and Fire Station Condition 7 Compatibility between school and fire station Traditional detailing Standing seam metal roof Architectural Glass garage bay doors (fire station) Treatment Generous use of windows (school) Brick facades Conditions 8 & 12 Solid waste storage areas, fuel pumps and similar uses screened from Screening public rights of way and adjacent properties with solid masonry wall (Fire Station and Conditions 9 & 14 School) Placed along north, east and west elevations Foundation Plantings Condition 10 (Fire Station) Not permitted External Sirens/Pubic Conditions 11 & 13 Address Setback of 100 feet from residential properties Buffer/setbacks for Includes 50-foot buffer athletic fields Condition 15 819SN0579-2019MAR13-BOS-RPT Ordinance Exceptions Within Corporate Office (O-2) Districts, the Zoning Ordinance requires conformance to development standards of the Ettrick Special Design District which address setbacks for buildings and parking/drives, building height and size, street trees, and drive-in or drive-thru uses to include bays. To accommodate the proposed public facilities and the operation of fire apparatus, conditional use planned development is requested to permit exceptions to specific development standards and signage. These exceptions are outlined in the following chart, and the Textual Statement (Attachment 2). Standard Required Proposed Building Fire Station = maximum 15' Fire Station = approx. 19 Setbacks (Chesterfield School = maximum 15 School Ave.) Parking/Drive Behind rear walls of buildings Between rear walls of buildings and Setbacks Chesterfield Ave. and Paine St. (Fire Station and School) Building Minimum of two (2) stories One (1) story (Fire Station and Height School) Building Size Maximum of 10,000 sq. ft. Fire Station = 16,000 sq. ft. School = 100,000 sq. ft. Parking Spaces 1 space per 200 sq. ft. of area = No on-site parking spaces (Neighborhood approx. 15 spaces Park only) Street Trees 1 tree per 40 linear feet Alternate design including four (4) (Park Only) large deciduous specimen trees (2 existing to be retained) Free-standing Nonresidential Community = One Three (3) free-standing monument- Signs (1) sign with 32 sq. ft. of area and style signs containing 32 sq. ft. of in height each Note: Site will also include relocation of existing Ettrick Village Sign Drive-in or Bays located behind buildings to Fire apparatus bays directly facing Drive-thru minimize views from Chesterfield Chesterfield Ave./Granger St./River facilities to Ave./Granger St./River Rd. Rd. Include Bays 919SN0579-2019MAR13-BOS-RPT COUNTY DEPARTMENT OF TRANSPORTATION Staff Contact: Steve Adams (804) 748-1037 adamsSt@chesterfield.gov The Comprehensive Plan, which includes the Thoroughfare Plan, identifies county-wide transportation needs that are expected to mitigate traffic impacts of future growth. The anticipated traffic impact of the proposal has been evaluated and recommendations are detailed in the chart below: Potential Site Plan Recommendations Right of Way Recordation 35 feet from centerline along Chesterfield Avenue, a collector on the Thoroughfare Plan. Road Improvements Traffic signal modification at the Chesterfield Avenue/Granger Street intersection to accommodate the fire station access. Bikeway/Trail accommodation that corresponds with the Bikeways and Trails Plan along Chesterfield Avenue, if applicable. Sidewalk along the entire property frontage to Chesterfield Avenue and Paine Street (coordinate with Ettrick Special Area Plan). Dedication of right-of-way (or easements) to accommodate the road improvements referenced above. School area traffic control signs along Chesterfield Avenue. School layout to provide adequate vehicle storage for student drop-off area and on-site parking to minimize impacts to Chesterfield Avenue. 1019SN0579-2019MAR13-BOS-RPT VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Adam Wilkerson (804-674-2384) adam.wilkerson@vdot.virginia.gov The new Ettrick Elementary School is to be constructed on the site of the existing school, located at the intersection of Chesterfield Avenue (Route 36) and Paine Street (Route 1104). The proposed schematic layout of the new school site includes one access on Chesterfield Avenue near the James Street intersection. A review of the rezoning application and Overall Conceptual Plan (Attachment 3) identified the following comments: VDOT Access Management regulation will apply along Chesterfield Avenue, a 25 MPH Urban Minor Arterial. Please note the following minimum spacing requirements: o Unsignalized intersection spacing is 660 feet o Full access entrance spacing is 355 feet o Partial access entrance spacing is 200 feet Clarify if the proposed school access off of Chesterfield Avenue is to be a state maintained or private road. It appears that this access road could create a four- way intersection on Chesterfield Avenue with James Street. A VDOT access management exception would be required for this unsignalized intersection spacing from the signalized intersection of River Road and Chesterfield Avenue. In addition, turn lane warrants will be necessary for the new access road, and may require a right and/or left turn lane on Chesterfield Avenue. The proposed park along the school frontage on Chesterfield Avenue appears to maintain sidewalk directly behind the road curb. Since on-street parking is permitted on the road, VDOT standards will require a minimum 8-foot wide sidewalk in this area. The location of the bus loop at the intersection of Paine Street and Rutledge Avenue will need to be analyzed to verify bus traffic can be accommodated at this location. The site plan will need to address how access to American Legion Post #136 at 21008 Rutledge Avenue will be maintained. Typically, public school bus loops are restricted to prohibit private access. Please note that VDOT did not review or provide comments for the future fire station site included on the Conceptual Model (Attachment 4). Formal comments will be provided during the site plan process once detailed engineering plans are submitted for review. Coordination with VDOT Traffic Engineering section will be required prior to any modifications of the existing traffic signal. 1119SN0579-2019MAR13-BOS-RPT SCHOOLS Staff Contact: Atonja Allen (804-318-8740) atonja_allen@ccpsnet.net Mission High performing, high quality public schools contribute to the quality of life and economic vitality of the County. The comprehensive plan suggests a greater focus should be placed on linking schools with communities by providing greater access, flexible designs and locations that better meet the needs of the communities in which they are located. Capital Improvements The School Board FY2019 adopted Capital Improvement Plan (CIP) continues to support the 2013 voter approved school revitalization program that will replace or renovate ten schools and construct one new elementary school to add capacity in the Midlothian area of the county. The ten existing facilities that are part of the revitalization program are Beulah Elementary School, Crestwood Elementary School, Enon Elementary School, Ettrick Elementary School, Harrowgate Elementary School, Matoaca Elementary School, Reams Elementary School, Manchester Middle School, Providence Middle School, and Monacan High School. A replacement Enon Elementary School is currently in construction on the existing school site, a replacement Manchester Middle School is planned for construction on the existing school site, and the Beulah Elementary School, Providence Middle School, and Monacan High School projects are complete. Additional school construction projects include a Matoaca Middle School addition on the east campus site, and the new Matoaca Elementary School will be constructed on the existing west campus site. Upon completion of the east campus addition, the current west campus building will be demolished and Matoaca Middle School will operate as a single, unified campus. Information on the CIP and School Board approved construction projects can be found in the financial section of the CCPS Adopted Budget for FY2019. Public Facilities Plan Ettrick Elementary School is listed in the Public Facilities Plan as a facility recommended for revitalization or replacement within the 2014-2020 cycle. The replacement Ettrick Elementary School will be built at the current location using the 750 design capacity prototype. Per School Board Policy 7240 (Long-Range Educational Facilities Planning), the School Board, where feasible, will plan for new schools and renovations based on community-oriented principles, which include planning school additions or renovations with the neighboring community in mind and sharing facilities through joint-use or co-location with other public facilities. 1219SN0579-2019MAR13-BOS-RPT FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov Nearby Fire and Emergency Medical Service (EMS) Facilities Fire Station The Ettrick Fire Station, Company Number 12 EMS Facility The Ettrick-Matoaca Volunteer Rescue Squad Public Facilities Plan The Ettrick Fire Station #12 was constructed in 1929 and provides less than adequate facility support for the delivery of fire and emergency medical services. The department is replacing the station with a facility that is better capable to house modern fire apparatus, accommodate a diversified workforce, and provide better access to public visitors. The Public Facilities Plan recommends that this facility be revitalized or replaced within the 2018 2022 cycle and be located in the same general area as the existing station. The replacement station will provide ues and delivery of service. Additional Fire Comments When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov The subject property is located within the mandatory water and wastewater connection areas for non-residential development; therefore, connection to the public water and wastewater systems is required by County Code. property line of the school site (GPIN 794-611-7377) at the intersection of Rutledge Avenue and Avenue. parcels ide -611-7377) and an existing on of Rutledge Avenue and Paine Street. The developer has stated the intention to connect to the public water and wastewater system (Condition 5). 1319SN0579-2019MAR13-BOS-RPT Specifications and Procedures, including the abandonment or relocation of facilities impacted by the development. The Utilities Department supports this case. 1419SN0579-2019MAR13-BOS-RPT 1519SN0579-2019MAR13-BOS-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) wardr@chesterfield.gov Geography The majority of the subject properties drain from north to south directly into a tributary of the Appomattox River. All of the subject properties are located within the Appomattox River Watershed. Environmental Features A Resource Protection Area (RPA) Designation was completed by the applicant and reviewed and confirmed by the Department of Environmental Engineering Water Quality Section. RPA exists along the tributary on the western portion of the properties located at 20800 and 20910 Chesterfield Avenue, as well as along the western edge of 21004 Rutledge Avenue. A Water Quality Impact Assessment must be submitted to and approved by the Department of Environmental Engineering and/or the Board of Supervisors for any improvements which encroach into the RPA. Additionally, there may be areas of wetlands within the drainage ways located on the property. Wetlands and/or streams shall not be impacted without approval from the U.S. Army Corps of Engineers and/or the Virginia Department of Environmental Quality. Drainage The subject properties primarily drain into a tributary which drains from north to south directly to the Appomattox River. Approximately 280 feet downstream of the subject properties, the tributary comes within 10-15 feet of an existing residential dwelling. This property was recorded prior to the adoption of the Floodplain Ordinance in 1983; therefore, any increase in the 100-year discharge rate from the development of the subject properties may result in increased flooding. In addition, the existing tributary is showing signs of erosion, thus, any increased runoff from the proposed development and/or redevelopment of the existing school property may result in increased erosion, which will impact private properties. As a result, on-site retention/detention of the 2-year, 10-year, and 100-year storm post-development peak discharge rates from the site to below the 2-year, 10-year, and 100-year storm peak discharge rates, respectively, from the site in a forested condition, shall be provided, unless otherwise approved by the Department of Environmental Engineering at the time of plans review (Condition 6). Stormwater Management The overall development is subject to the Part IIB technical criteria of the Virginia Stormwater Management Program Regulations for water quality and water quantity. 1619SN0579-2019MAR13-BOS-RPT PARKS AND RECREATION Staff Contact: Stuart Connock (804-751-4484) ConnockS@chesterfield.gov Mission The County supports a high-quality park system to provide residents and visitors with equitable access to active and passive recreation opportunities. The 2018 level of service is 7.5 acres of regional, community and neighborhood parkland per 1,000 persons whereas the target level of service is 9 acres per 1,000 persons. Nearby Parks and Recreational Facilities Matoaca Park Ettrick Park VSU Trail Park Matoaca High School Matoaca Middle School East Matoaca Middle School West Matoaca Elementary School Ettrick Elementary School Ettrick Elementary School Annex Public Facilities Plan The Public Facilities Plan identifies the need for a regional park facility of 200 acres, nearest this location. Land for this park has not been acquired. The Public Facilities Plan suggests neighborhood parks to supplement community and regional parks in underserved areas. Currently, there is no parkland within the residential area of Ettrick Village. A neighborhood park in this area would supplement park needs. Special purpose parks are also identified in this plan due to proximity of the Appomattox River and extensive cultural history of the Ettrick Village. The Public Facilities Plan recommends routes identified on the Bikeways and Trail Plan connecting to public parks and other destinations. The Public Facilities Plan and Parks and Recreation Comprehensive Master Plan shows a Bikeways and Trails route along Chesterfield Avenue. Recommendation The school plan preserves greenspace along the southern side of Chesterfield Avenue. This area meets the criteria for a neighborhood/urban park. The proposed park will assist in meeting the underserved part of the county. The proposed Ettrick Urban Park and recreational space as part of the new Ettrick Elementary School will increase neighborhood park acreage and continue shared use of recreational facilities with the school. Parks and Recreation supports the park use and proposed development plan for all three facilities, school, fire station and park. The Bikeways and Trails chapter of the Comprehensive Plan shows a route along Chesterfield Avenue, best located on the north side of Chesterfield Avenue with connections to the adjacent 1719SN0579-2019MAR13-BOS-RPT facilities. Crosswalks should be planned along Chesterfield at Payne Street and Granger Street to provide an opportunity to connect the proposed Fire Station, Ettrick Elementary School and Ettrick Neighborhood/Urban Park with the planned trail along Chesterfield Avenue. Summary of Identified Issues The shortage of parkland in the area is addressed by the proposed Neighborhood/Urban Park. Additional Parks Comments The forested area located west of the proposed Ettrick Elementary School property includes a trail with interpretive signage. 1819SN0579-2019MAR13-BOS-RPT CASE HISTORY Applicant Submittals 1/2/19 Application submitted 2/12/19 Textual Statement submitted Community Meeting 1/29/19 Issues discussed: Impacts on neighboring businesses Timeline for development of facilities Community Meeting 2/5/19 Issues discussed: Demolition of existing buildings on site Reassignment of Ettrick Elementary School students to Mataoca Elementary School during demolition and construction of new school Planning Commission 2/19/19 Citizen Comments: No citizens spoke to this request. Commission Discussion: Mr. Stariha recognized staff from Planning, Schools, Fire and Parks for their collaborative effort on the case and that the proposal demonstrates good fiscal stewardship and is supported by leaders of Virginia State University. Recommendation APPROVAL SUBJECT TO THE CONDITIONS IN ATTACHMENT 1 Motion: Sloan Second: Stariha AYES: Jackson, Freye, Sloan, Jones and Stariha The Board of Supervisors on Wednesday, March 13, 2019, beginning at 6:00 p.m., will consider this request. 1919SN0579-2019MAR13-BOS-RPT ATTACHMENT 1 CONDITIONS Note: The following conditions are recommended by both the Planning Commission and Staff. The following provisions shall be required for the development of all uses proposed on the subject property (Fire Station, Public Elementary School and Neighborhood Park). 1.Use Limitations. Uses on the property shall be limited to a Fire and EMS Station, a public Elementary School to include accessory uses such as outdoor recreational playfields and courts, and a public Neighborhood/Urban Park. Walking/fitness trails shall be permitted throughout the entire public property. (P) 2.Master Plan. The Textual Statement last revised 2/12/2019 shall be considered the Master Plan. (P) 3.Conceptual Plans. The property shall be developed generally as shown on the Conceptual Plans as referenced below, with respect to the general location and orientation of buildings, the general layout of parking and drives, and the general location of sidewalks and trails, and other recreational and pedestrian amenities. Adjustments to the Conceptual Plans may be approved at the time of plans review, provided such adjustments substantially retain the relationship between different uses to each other and to rights-of-way, and recreational facilities. If adjustments are deemed to be significant as determined by the Planning Department, the Conceptual Plans shall be presented to the Planning Commission for final approval. a.Overall Conceptual Plan prepared by Chesterfield County Department of Parks and Recreation and dated January 25, 2019 (Exhibit A). b.Fire Station Conceptual Model prepared by GuernseyTingle and dated January 25, 2019 (Exhibit B). c.Conceptual Development Plan prepared by Chesterfield County Department of Parks and Recreation and dated January 25, 2019 (Exhibit C). (P) 4.Sidewalks. A sidewalk with a minimum width of 5 feet shall be provided along the entire property frontage adjacent to Chesterfield Avenue and along the entire property frontage adjacent to Paine Street, unless otherwise required by VDOT. (P) 5.Utilities. Public water and wastewater systems shall be used. (U) 2019SN0579-2019MAR13-BOS-RPT 6.Stormwater Requirements. On-site retention/detention of the 2-year, 10-year, and 100-year storm post-development peak discharge rates from the site to below the 2- year, 10-year, and 100-year storm peak discharge rates, respectively, from the site in a forested condition shall be provided, unless otherwise approved by the Department of Environmental Engineering at time of plans review. (EE) 7.Fencing. Fencing, a minimum of four (4) feet in height, shall be located generally between the school parking areas and Paine Street, between the school parking areas and the Neighborhood Park, and between the school parking areas and the Fire Station site as approved by the Planning Department at time of plans review. The fence shall consist of brick columns with ornamental metal fencing in between columns. (P) The following provisions shall apply to individual uses on the subject property. Fire Station: 8.Architectural Treatment. Architectural treatment shall be compatible with the proposed Ettrick Elementary School building. Building exteriors shall be masonry and fenestration shall be harmonious with neo-traditional architectural character. Building massing shall be designed to avoid large, unbroken facades. Additional architectural detailing shall include: a.Traditional cornice detailing to include fascia, soffit and frieze trim. b.Traditional window and door surrounds of masonry or cast stone. c.Standing seam metal roof. d.Glass garage bay doors. (P) 9.Screening of Solid Waste Storage Areas, Fuel Pumps and other similar uses. Solid waste storage areas, fuel pumps and other similar uses, regardless of their location on the site, shall be screened from view of adjacent property and public rights-of-way with a masonry wall which is constructed of comparable materials to, and designed to be compatible with the fire station. (P) 10.Foundation Plantings. Building elevations facing north, east and west shall be enhanced with foundation planting beds. Exact treatment and plantings shall be determined by the Planning Department at the time of plans review. (P) 11.External Sirens and Public-Address Systems. There shall be no external building mounted sirens or public-address systems. (P) 2119SN0579-2019MAR13-BOS-RPT Elementary School: 12.Architectural Treatment. The school building shall include the following materials and architectural features or better: a.Generous use of windows at ground floor, along street-facing facades b.Traditional cornice detailing to include fascia, soffit and frieze trim c.Traditional window and door elements of masonry or cast stone d.Brick, cast stone or other comparable masonry materials on all sides of building e.Standing seam metal roof (P) 13.Public-Address Systems. There shall be no external public-address systems. (P) 14.Screening of Solid Waste Storage Areas. Solid waste storage areas and other similar uses, regardless of their location on the site, shall be screened from view of adjacent property and public rights-of-way with a masonry wall which is constructed of comparable materials to, and designed to be compatible with the school. (P) 15.Athletic Fields and Playfields. Except for playground areas which accommodate swings, jungle gyms, or similar such facilities, all active playfields, courts or similar active recreational facilities which would accommodate organized sports such as football, soccer, basketball, etc., shall be setback a minimum of 100 feet from any adjacent properties zoned for residential purposes. Within this setback, a fifty (50) foot buffer shall be provided in accordance with zoning ordinance requirements. Trails shall be permitted to be located within setbacks and buffers. (P) 16.Certificate of Occupancy. Prior to issuance of a certificate of occupancy for the elementary school, road improvements as required by the Virginia Department of Transportation, on-street parking spaces, street lighting and sidewalks along Chesterfield Avenue, and sidewalks along Paine Street shall be completed. (P) 17.Maintenance of Future Neighborhood/Urban Park Area. The neighborhood/urban park area shall be maintained as an open green space until such time as the park facilities are developed. (P) Neighborhood Park: 18.Park Uses. The neighborhood park located in the southwestern quadrant of Chesterfield Avenue and Paine Street shall be limited to passive recreational uses such as hardscaped areas with benches and tables, open green spaces, landscape beds and public art/sculptures. (P) 2219SN0579-2019MAR13-BOS-RPT ATTACHMENT 2 TEXTUAL STATEMENT (February 12, 2019) Development of the subject property for a fire station, public elementary school and park shall meet the standards of the Ettrick Special Design District, except as provided below. Fire Station Standards: Setbacks: A.Buildings: There shall be no maximum setback from Chesterfield Avenue. B.Parking: Parking areas shall be permitted to be located between the rear wall of the building and Chesterfield Avenue, however no parking area shall be located between the front façade of the building and Chesterfield Avenue. Minimum Building Height: Building height of one (1) story shall be permitted. Building Size: No building shall exceed 16,000 gross square feet. Uses to Include Bays: Vehicle bays shall be permitted along the front façade oriented towards Chesterfield Avenue. Elementary School Standards: Setbacks: A.Buildings: There shall be no maximum setback from Chesterfield Avenue. B.Parking and Drives: Parking and drives shall be permitted to be in front of the rear wall of the building, and between the building and Chesterfield Avenue and Paine Street. Minimum Building Height: Building height of one (1) story shall be permitted. 2319SN0579-2019MAR13-BOS-RPT Building Size: No building shall exceed 100,000 gross square feet. Neighborhood/Urban Park Standards: Parking: A.There shall be no requirement for on-site parking spaces. B.In lieu of the street tree requirement, four (4) large specimen Oak trees shall be provided and/or maintained in accordance with the Conceptual Development Plan prepared by Chesterfield County Department of Parks and Recreation and dated January 25, 2019. Should specimen Oak trees be removed, street trees shall be provided along Chesterfield Avenue in accordance with Ordinance requirements. Other Development Standards: The following standards shall apply to all uses on the property. Free-Standing Signs: A.A maximum of three (3) free-standing signs shall be permitted along Chesterfield Avenue. These signs shall be allocated to each of the three uses on the property (Elementary School, Fire Station and Park). B.A comprehensive sign package shall be submitted to and approved by the Planning Department. C.All free-standing signs shall meet the following standards: a.Height: Signs, including any architectural features comprising the sign structure, shall not exceed 8 feet from grade. b.Area: Signs shall contain a maximum of 32 feet in area. c.Signs shall be of a monument style. 2419SN0579-2019MAR13-BOS-RPT ATTACHMENT 3 EXHIBIT A, OVERALL CONCEPTUAL PLAN 2519SN0579-2019MAR13-BOS-RPT ATTACHMENT 4 EXHIBIT B, CONCEPTUAL MODEL (FIRE STATION) 2619SN0579-2019MAR13-BOS-RPT ATTACHMENT 5 EXHIBIT C, CONCEPTUAL DEVELOPMENT PLAN (NEIGHBORHOOD/URBAN PARK) 2719SN0579-2019MAR13-BOS-RPT