Loading...
20SN0518 CASE NUMBER: 20SN0518 APPLICANTS: Chesterfield County Board of Supervisors CHESTERFIELD COUNTY, VIRGINIA MIDLOTHIAN DISTRICT AND RECOMMENDATION Board of Supervisors (BOS) Hearing: OCTOBER 23, 2019 BOS Time Remaining: 365 DAYS DARLENE LATHROP (804-768-7567) Planning Department Case Manager: DREW NOXON (804-796-7122) 4.7 Acres 13900 and 13910 Winterfield Lane REQUEST Amendment to zoning approval (Case 18SN0732) to amend development requirements on 4.2 acres zoned Residential (R-7) and an adjacent 0.5-acre public right-of-way zoned Residential (R-12) in the vicinity of Winterfield Lane and Midlothian Turnpike. Notes: A.Conditions may be imposed or the property owner may proffer conditions. B.Conditions, Textual Statement, Exhibits and approved zoning conditions are located in Attachments 1 7. SUMMARY A public fire and emergency medical service (EMS) station is planned. With the original zoning approval, a north/south road was proposed through the site. During the site engineering process, it was determined that environmental and topographic issues would preclude the construction of the north/south roadway through the site. As a result, access to the site is being adjusted to include a direct entrance from Midlothian Turnpike across from Charter Colony Parkway. Modifications are requested to Conditions 1, 2, 3 (item b.), 5, 9, 10 and 12 of Case 18SN0732 regarding the approved Master Plan, building location, architectural treatment, foundation plantings, sidewalks, street trees, a rear buffer, and deletion of references to the north/south roadway. Condition 8 requiring dedication of the north/south public road right-of-way would be deleted in its entirety. An exception to Ordinance requirements is requested to permit an alternative perimeter landscaping treatment in the front parking setback adjacent to Midlothian Turnpike and side parking setbacks as described herein. Providing a FIRST CHOICE community through excellence in public service RECOMMENDATIONS APPROVAL PLANNING COMMISSION APPROVAL Amendments provide flexibility for development on constrained site STAFF As conditioned, minimizes impacts on area development 220SN0518-2019OCT23-BOS-RPT 320SN0518-2019OCT23-BOS-RPT Comprehensive Plan (Midlothian Area Community Plan) Classification: VILLAGE FRINGE AREA The designation suggests the property is appropriate mixed-use development compatible with surrounding neighborhoods and including primarily office, multi-unit housing, community facilities, and personal services. The Public Facilities Plan suggests a new facility should be located in the vicinity of Midlothian Turnpike and Winterfield Road to address service demands and physical requirements of a professional station. Surrounding Land Uses and Development Residentially Single-family zoned/Vacant residential uses Winterfield Ln Midlothian Tnpk Charter Colony Shopping Center Charter Colony Pkwy 420SN0518-2019OCT23-BOS-RPT PLANNING Staff Contact: Drew Noxon (804-796-7122) noxona@chesterfield.gov Proposal Relocation of the Midlothian Fire/EMS Station is planned. The Fire Department suggests the site is needed to better meet the growing needs in the Midlothian community. The Forest View Volunteer Rescue Squad will continue to occupy and provide emergency medical services from the existing station located at 13420 Midlothian Turnpike. On May 23, 2018, the Board of Supervisors approved a zoning request for the proposed fire station (Case 18SN0732). Conditions of zoning required the dedication of right-of-way for a north/south road through the property to serve as a continuation of Charter Colony Parkway. With additional site engineering, plans to construct this north/south road have been abandoned due to topographic and environmental constraints. Multiple approved conditions include references to a north/south road. The applicant requests amendments to remove these references. Adjustments to the site access and building location have necessitated amendments to several approved conditions (Exhibit A). In addition, a revised conceptual building elevation has been provided (Exhibit B). The chart on the following page contains a summary of amendments to the previous zoning conditions. 520SN0518-2019OCT23-BOS-RPT General Overview Requirements Existing zoning - Case 18SN0732 Proposed amendments Textual Statement dated 4/13/2018 Revised Textual Statement dated as Master Plan 9/9/2019 as Master Plan Master Plan Condition 1 and Attachment 5 Condition 1 and Attachment 2 Located on site as generally shown on Located on site as generally shown on concept site plan dated April 2, 2018 concept site plan dated 7/30/2019 Building Location Condition 2 and Attachment 6 Condition 2 and Exhibit A Generous use of windows at Removed references to ground- ground floor, along sides of floor and north/south road. Architectural building facing the North/South Revised building has a 1-story Treatment road design Condition 3. b. and Attachment 7 Condition 3. b. and Exhibit B Placed along north, south and east Placed along south, east and west Foundation elevationselevations Plantings Condition 5 Condition 4 60-foot wide r.o.w. from Charter Deleted Colony Pkwy. to northeast corner Right-of-Way of site dedication Condition 8 Reference to north/south roadway Sidewalks along both sides of removed Sidewalk along north side of Sidewalks Midlothian Turnpike Condition 5 Condition 9 Reference to north/south roadway Street trees along both sides of removed Street trees along north side of Street Trees Midlothian Turnpike Condition 6 Condition 10 25-foot buffer along northern 50-foot buffer along northern property & allowance for property line, no allowance for Buffers stormwater facilities to encroach stormwater facilities to encroach Condition 12 Condition 7 620SN0518-2019OCT23-BOS-RPT Exception to Perimeter Landscaping (Front and Side Parking Setbacks) Development of parking areas and drives for non-residential uses are subject to the requirements of the Midlothian Special Design District (Fringe Area). Within parking setback from side lot lines and Midlothian Turnpike the Ordinance requires perimeter landscaping consisting of deciduous and evergreen trees and shrubs of various sizes and with specific spacing arrangements. An exception to this landscaping requirement is requested to allow stormwater facilities to be located within the landscaped area. The applicant proposes that the exact treatment of these setback areas be determined at the time of site plan review, to provide possible variation in planting treatment consistent with that of existing and planned development within the Midlothian Village. COUNTY DEPARTMENT OF TRANSPORTATION Staff Contact: Steve Adams (804) 748-1037 adamsSt@chesterfield.gov The Comprehensive Plan, which includes the Thoroughfare Plan, identifies county-wide transportation needs that are expected to mitigate traffic impacts of future growth. The anticipated traffic impact of the proposal has been evaluated and recommendations are detailed in the chart below: Potential Site Plan Recommendations Right of Way Recordation 45 feet from centerline along Midlothian Turnpike (Route 60), a major arterial on the Thoroughfare Plan. Vehicular Access Control Access to Route 60 limited to 1 entrance/exit located across from the Route 60/Charter Colony Parkway intersection. Road Improvements Realignment of Winterfield Lane intersection with Route 60. New alignment shall meet VDOT standards and will require dedication of right-of-way to ensure state maintenance. Re-stripe eastbound Route 60 to accommodate an adequate left turn lane into the proposed road/fire station access. Traffic signal modification at the Route 60/Charter Colony Road intersection to accommodate the proposed access. Maintain/re-establish sidewalk along the entire property frontage to Route 60. Dedication of right-of-way (or easements) to accommodate the road improvements referenced above. 720SN0518-2019OCT23-BOS-RPT FIRE AND EMERGENCY MEDICAL SERVICES Staff Contact: Anthony Batten (804-717-6167) battena@chesterfield.gov When the property is developed, the number of hydrants, quantity of water needed for fire protection, and access requirements will be evaluated during the plans review process. Nearby Fire and Emergency Medical Service (EMS) Facilities Fire Station The Midlothian Fire Station, Company Number 5 EMS Facility The Forest View Volunteer Rescue Squad UTILITIES Staff Contact: Jamie Bland (804-751-4439) blandj@chesterfield.gov Existing Water and Wastewater Systems Currently Size of Closest Existing Connection Required by County Utility Type Serviced Lines Code Water No 24 Yes Wastewater No Yes The subject properties are located within the mandatory water and wastewater connection areas for new non-residential structures. County water is available for connection in the Midlothian Turnpike right-of-way. County wastewater is not immediately available for connection to the properties and will require offsite extension to be made available. The submitted conceptual plan indicates two alternatives, one from the west at Winterfield Rd, and one from the east at Jefferson Green Cir. These alternatives will be evaluated at time of site plan submittal, conceptually either are acceptable to the Utilities Department. The Utilities Department supports this case. 820SN0518-2019OCT23-BOS-RPT 920SN0518-2019OCT23-BOS-RPT ENVIRONMENTAL ENGINEERING Staff Contact: Rebeccah Ward (804-748-1028) wardr@chesterfield.gov Geography The western and southwestern third of the subject properties generally drain southwest towards existing Winterfield Lane, through a culvert under Winterfield Road, and into the pond within the Midlothian Town Center development. The eastern and northeastern two-thirds of the properties drain northeast towards private properties. The properties are located within the Falling Creek and James River Watersheds. Environmental Features A Resource Protection Area Designation (RPAD) must be submitted to the Department of Environmental Engineering Water Quality Section prior to the submittal of any site plans. In addition, wetlands shall not be impacted without prior approval from the U.S. Army Corps of Engineers and/or the Virginia Department of Environmental Quality. Stormwater Management The development of the subject properties will be subject to the Part IIB technical criteria of the VSMP Regulations for water quality and quantity. Offsite easements may be necessary to discharge stormwater to an adequate conveyance system. VIRGINIA DEPARTMENT OF TRANSPORTATION Staff Contact: Jonathan Phillippe (804-674-2560) jonathan.phillippe@vdot.virginia.gov PARKS AND RECREATION Staff Contact: Stuart Connock (804-751-4484) ConnockS@chesterfield.gov This request will not impact these facilities. 1020SN0518-2019OCT23-BOS-RPT CASE HISTORY Applicant Submittals 8/1/19 Application submitted 9/9/19 Textual Statement submitted Community Meeting 8/26/19 No citizens attended Planning Commission 9/17/19 Citizen Comments: No citizens spoke to this request. Recommendation APPROVAL SUBJECT TO THE CONDITIONS IN ATTACHMENT 1 Motion: Jones Second: Freye AYES: Jackson, Freye, Jones, Stariha and Sloan The Board of Supervisors on Wednesday, October 23, 2019, beginning at 6:00 p.m., will consider this request. 1120SN0518-2019OCT23-BOS-RPT ATTACHMENT 1 CONDITIONS Notes: The following conditions are recommended by both the Planning Commission and Staff. Conditions 1, 2, 3, 5, 9, 10 and 12 of Case 18SN0732 shall be amended as provided below. Condition 8 of Case 18SN0732 shall be deleted in its entirety. All other conditions of Case 18SN0732 shall remain in force and effect. 1.Master Plan. The Textual Statement dated 9/4/2019 shall be considered the Master Plan. (P) 2.Building Location: The fire station building shall be located as generally shown on the Concept Site Plan by Guernsey Tingle dated July 30, 2019. (P) 3.Architectural Treatment. The fire station building shall include the following materials and architectural features or better: a.Neo-traditional style and detailing based on the context of the Midlothian Village area b.Generous use of windows along sides of the building visible from Midlothian Turnpike and Winterfield Lane c.Traditional cornice detailing to include fascia, soffit and frieze trim d.Traditional window and door surrounds of masonry or cast stone e.Brick, cast stone or other comparable masonry materials on all sides of building f.Standing seam metal roof g.Glass garage bay doors (P) 4.Foundation Plantings. Building elevations facing south, east, and west shall be enhanced with foundation planting beds. Exact treatment and plantings shall be determined by the Planning Department at the time of site plan review. (P) 5.Sidewalks. A sidewalk with a minimum width of 5 feet shall be placed along the entire property frontage adjacent to Midlothian Turnpike (Route 60). (P) 6.Street Trees. Street trees shall be placed along the north side of Midlothian Turnpike (Route 60) and the east side of Winterfield Lane. Spacing of street trees shall be 35 feet on center, however, where lines of site along Midlothian Turnpike in proximity to the vehicle bays are to be protected, the Planning Director shall allow a clear visual obstruction area. (P) 1220SN0518-2019OCT23-BOS-RPT 7.Buffer. A 50-foot buffer shall be provided along the northern property line adjacent to 727-709-2744, 727-709-1844, 727-709-1147, & 726-709-9746 (13901, 13907, 13913 & 13921 Westfield Road). This buffer may be reduced or eliminated should these adjacent properties be developed for non-residential uses or should future rights-of-way be dedicated on the site, as approved by the Planning Department at the time of site plan review. Such buffer shall comply with requirements of the Ordinance for buffers of (50) feet in width. (P) 1320SN0518-2019OCT23-BOS-RPT ATTACHMENT 2 TEXTUAL STATEMENT (9/9/19) The following exceptions are requested to the Ordinance requirements for development of a fire station in residential districts: BMP/SWM facilities may be located within the front and side parking setbacks subject to approval by the Environmental Engineering Department and subject to the provision of landscaping and/or decorative fencing as approved by the Planning Department. 1420SN0518-2019OCT23-BOS-RPT ATTACHMENT 3 EXHIBIT A, CONCEPTUAL SITE LAYOUT 1520SN0518-2019OCT23-BOS-RPT ATTACHMENT 4 EXHIBIT B, CONCEPTUAL BUILDING ELEVATION 1620SN0518-2019OCT23-BOS-RPT ATTACHMENT 5 APPROVED CONDITIONS AND TEXTUAL STATEMENT (CASE 18SN0732) 1.Master Plan. The Textual Statement dated 4/13/2018 shall be considered the Master Plan. (P) 2.Building Location: The fire station building shall be located as generally shown on the Concept Site Plan by Guernsey Tingle dated April 2, 2018. (P) 3.Architectural Treatment. The fire station building shall include the following materials and architectural features or better: a.Neo-traditional style and detailing based on the context of the Midlothian Village area b.Generous use of windows at ground floor, along sides of the building facing the c.Traditional cornice detailing to include fascia, soffit and frieze trim d.Traditional window and door surrounds of masonry or cast stone e.Brick, cast stone or other comparable masonry materials on all sides of building f.Standing seam metal roof g.Glass garage bay doors (P) 4.Screening of Solid Waste Storage Areas, Fuel Pumps and other similar uses. Solid waste storage areas, fuel pumps and other similar uses, regardless of their location on the site, shall be screened from view of adjacent property and public rights-of-way by a masonry wall which is constructed of comparable materials to, and designed to be compatible with the fire station. (P) 5.Foundation Plantings. Building elevations facing south, east, and north shall be enhanced with foundation planting beds. Exact treatment and plantings shall be determined by the Planning Department at the time of site plan review. (P) 6.External Sirens and Public Address Systems. There shall be no external building mounted sirens or public address systems. (P) 7.Signage. Any freestanding identification or directional signage shall be of a monument design constructed of masonry complimentary to the fire station building. The exact treatment and design of the signage shall be approved by the Planning Department. (P) 8.Right-of-Way Dedication. Prior to any site plan approval, or within sixty (60) days from the date of a written request by the Planning Department, whichever occurs first, a sixty (60) foot wide right-of- the Midlothian Turnpike (Route 60)/Charter Colony Parkway intersection, through the Property to a location generally along the northeastern corner of the subject property, shall be dedicated, free and unrestricted, to and for the benefit of Chesterfield County. The exact location of this right-of-way shall be approved by the Planning Department. (P) 1720SN0518-2019OCT23-BOS-RPT 9.Sidewalks. Sidewalks with a minimum width of 5 feet shall be placed along both sides of the idlothian Turnpike (Route 60). (P) 10.Street Trees. Street trees shall be placed along both sides and along the north side of Midlothian Turnpike (Route 60). Spacing of street trees shall be 35 feet on center, however, where lines of site near the vehicle bays are to be protected, the Planning Director shall allow a clear visual obstruction area. (P) 11.Lighting. In addition to requirements of Section 19.1-205 of the Ordinance, lighting shall meet the following standards: a.Freestanding lights shall not exceed a height of 20 feet; and b.Building attached lighting shall be no higher than the roofline or parapet wall. (P) 12.Buffer. Within the required 40-foot rear setback, a 25-foot buffer shall be provided along the northern property li727-709-2744, 727-709-1844, 727-709- 1147, & 726-709-9746 (13901, 13907, 13913 & 13921 Westfield Road). This buffer may be reduced or eliminated should these adjacent properties be developed for non- residential uses, as approved by the Planning Department at the time of site plan review. Such buffer shall comply with requirements of the Ordinance for buffers less than fifty (50) feet in width, except that a BMP/SWM or any future east/west public right-of-way may be located within the buffer subject to approval by the Planning and Environmental Engineering Departments and with the minimum provision of a ten (10) foot wide landscaped strip between the BMP/SWM or right-of-way and the northern property line. (P) 1820SN0518-2019OCT23-BOS-RPT TEXTUAL STATEMENT (CASE 18SN0732) (4/13/18) The following exceptions are requested to the Ordinance requirements for development of a fire station in residential districts: Building Setbacks: e a minimum of ten (10) feet. Parking Setbacks: Parking areas shall be permitted to encroach beyond the front of the building provided that a minimum setback of 35 feet is maintained from Midlothian Turnpike (Route 60). The setback from the west sid (10) feet. The setback from the western property boundary shall be a minimum of ten (10) feet. Perimeter Landscaping: Landscaping treatment of setbacks shall generally consist of continuous planting strips with a variety of tree and shrub plantings to soften the appearance of the parking, drives, and building improvements as determined by the Planning Department at the time of site plan review. 1920SN0518-2019OCT23-BOS-RPT ATTACHMENT 6 APPROVED CONCEPTUAL SITE LAYOUT (CASE 18SN0732) 2020SN0518-2019OCT23-BOS-RPT ATTACHMENT 7 APPROVED CONCEPTUAL BUILDING ELEVATION (CASE 18SN0732) 2120SN0518-2019OCT23-BOS-RPT