Loading...
98SN0155.pdfREQUEST ANALYSIS AND RECOMMENDATION January 28, 1998 BS 98SN0155 Balanced Care Corporation Midlothian Magisterial District Northern terminus of Twim'idge Lane Rezoning from Residential Townhouse (R-TH) to Community Business (C-3) with Conditional Use to permit townhouse use. Townhouse use is permitted as a restricted use in a C-3 District. If the restrictions cannot be met, the use may be allowed by Conditional Use. The applicant would like to retain the right to develop the entire property for townhouse use. The restrictions in the C-3 District include a limitation that the use be limited to a maximum of thirty (30) percent of the gross acreage of the project. PROPOSED LAND USE: The applicant has agreed to limit development to a convalescent, nursing or rest home uses, nursery schools, child or adult day care facilities, pharmacies, and medical clinics or residential townhouses. pLANNING COMMISSION RECOMMENDATION RECOMMEND APPROVAL AND ACCEPTANCE OF THE PROFFERED CONDITIONS ON PAGES 2 AND 3. STAFF RECOMMENDATION Recommend approval for the following reasons: The proposed zoning and land uses, coupled with the proffered conditions, conform with the Northern Area I~nd USe and Tran~ortation Plan which suggests the property is appropriate for residential use of 4.01 to 7.0 units per acre. In addition, the proposed Midlothian Area Land Use Plan suggests the property is appropriate for residential use of 7.01 to 14 units per acre. Bo (NOTES: The proposed zoning and land uses are compatible with, and representative of, existing and anticipated area development. The requirements of the Development Standards Manual and proffered conditions will further insure land use compatibility with area development. CONDITIONS MAY BE IMPOSED OR THE PROPERTY OWNER MAY PROFFER COND~IONS ON THAT POR~ON OF THE REQUEST RELATED TO THE CONDITIONAL USE ~OWNHOUSE USE). Bo THE ONLY CONDITION THAT MAY BE IMPOSED ON THE COMMUNITY BUSINESS (C-3) ZONING IS A BUFFER CONDITION. THE PROPERTY OWNERS MAY PROFFER OTHER CONDITIONS. THE CONDITIOlqS NOTED WITH "STAFF/CPC" WERE AGREED UPON BY BOTH STAFF AND THE COMMISSION. CONDITIONS WITH ONLY A "STAFF" ARE ~COMMENDED SO!.F. LY BY STAFF. CONDITIONS WITH ONLY A "CPC" ARE ADDITIONAL CONDITIONS RECOMMENDED BY THE PLANNING COMMISSION.) PROFFERED COND~IONS (STAFF/CPC) 1. Public water and wastewater systems shall be used. (STAFF/CPC) Except for the timbering approved by the Virginia State Department of Forestry for the purpose of removing dead or diseased trees, there shall be no timbering on the Property until a land disturbance permit has been obtained from the Environmental Engineering Department and the approved devices have been installed. (STAFF/CPC) o The total number of residential units on the Property shall not exceed 104 units. NOTE: The present zoning is R-TH which allows up to 104 townhouse units. (STAFF/CPC) 4. The uses permitted on the Property shall be either: A. Any of the following: Convalescent homes, nursing homes and rest homes. Nursery schools and child or adult care centers. Medical clinics, provided that a substantial or significant portion of its practice is not performing abortions and provided that such use shall not be 2 98SN0155/WP/JAN280 iv. permitted until a certificate of occupancy has been issued for A.i. above. Medical offices, provided that a substantial or significant portion of its practice is not performing abortions and provided that such use shall not be permitted until a certificate of occupancy has been issued for A.i. above. or (STAFF/CPC) (STAFF/CPC) (STAFF/CPC) (STAFF/CPC) (STAFF/CPC) (STAFF/CPC) o 10. B. Townhouses. There shall be no access to Winterslow Road. Should a reduction be requested to the required seventy-five (75) foot buffer adjacent to residential zoning to the west no more than a 45' reduction in the buffer shall be requested. Unless required by the Utilities or Fire Department, the public water and wastewater systems shall not be extended from Winterslow Road. Site plans shall be submitted to the Pla~ning Commission for review and approval. Drainage improvements shall be designed and constructed to mitigate potential for erosion and downstream flooding. The exact design and treatment of the improvements shall be reviewed and approved at the time of site plan review. The architecture of the use listed in 4.A.i. above shall be compatible in material, style and colOr as generally shown on the architectural elevations attached as F, lhihiL~. At the time of Site Plan review, the Planning Commission may approve modifications requested by the developer if such modifications are deemed to comply with the spirit and intent of the proposed elevations. Any medical clinic or office built on the Property shall be compatible in material, style, and color with the approved elevations for the convalescent homes, nursing homes, and rest homes. 3 98SN0155/WP/JAN280 GENERAL INFORMATION Northern terminus of Twinridge Lane. GPIN 758-707-5623 and 5783 (Sheet 8). Existing Zoning: R-TH 13.0 acres Existing Land Use: Vacant Adjacent Zoning & Land Use: North - 0-2 with Conditional Use Planned Development and R-15; Vacant South - R-15 with Conditional Use Planned Development; Commercial (nursing home) and multi,family residential East - R-15; Single family residential, commercial or vacant West - R-15; Single family residehtial or vacant Public water System: There is an existing eight (8) inch water line along Mayflower Drive, adjacent to the request site. In addition, there is an existing eight (8)inch water line in Twinridge Lane, adjacent to the site. Use of the public water system is intended and has been proffered 0~offered Condition 1). To address citizen concerns, the applicant has offered that there will be no utility, service provided from Winterslow Road unless required by the Utilities Department. (Ih:offered Condition 7) Public Wastewater System: There is an existing thirty-six (36) inch wastewater trunk line extending along the north side of Mayflower Drive and adjacent to the request site. In addition, there is an existing eight (8) inch wastewater collector in an easement approximately 200 feet southwest of the request site. Use of the public wastewater system is intended and has been proffered 4 98SN0155/WP/JAN280 (Proffered Condition 1). To address citizen concerns, the applicant has offered that there will be no utility service provided from Winterslow Road, unless required bY the Utilities Department. (~offered Condition 7) ENVIRONMENTAL Drainage and Erosion: The request site drains in two (2) directions. An adequate natural watercourse does not exist to accommodate runoff from development of this property. Part of the site drains to the north under Mayflower Drive to the floodplain of Powhite Creek. Mayflower Drive and properties along Mayflower Drive experience flooding problems. Another portion of the property drain.q to the west through Bon Air Hills Subdivision. Bon Air Hills 'Subdivision was constructed approximately thirty (30) years ago at a time when approval of road and drainage plans was not required by the County. There are no recorded drainage easements in Bon Air Hills Subdivision between Fairwood Drive and the request property. Because information is unavailable at this time, it is not known whether the culverts under Fairwood Drive are adequate to accommodate additional runoff if easements could be obtained to Fairwood Drive. Currently, neither the subject property nor adjacent properties through which this property drains are experiencing any erosion problems. However, soils below the 300 foot contour are highly erodible when disturbed or when runoff is charmel~ed. Off-site easements and improvements will be required to accommodate runoff from development of the request property. If runoff is not properly channelized, downstream flooding could increase. Also, if drainage channels are not constructed with rigid linings, severe erosion will occur. Staff has discussed these concerns with the applicant. The applicant has agreed to bring the site plan to the Planning Commission for review and approval (Proffered Condition 8) and that drainage improvements would be designed and constructed to mitigate potential for erosion and downstream flooding (~offered Condition 9). At time of site plan review, staff will suggest that conditions be imposed to prohibit impervious surfaces from draining westward ~eSs a rigid ouffall device is installed and require that drainage to the north be conveyed via rigid devices to Mayflower Drive. The applicant has proffered that, with the exception of timbering which has been approved by the Department of Forestry to remove dead Or diseased trees, there will be no timbering until a land disturbance permit has been obtained from the EnviroNmental Engineering Department (Proffered Condition 2). This will insure that proper erosion control measures are in place prior to any timbering and related land disturbance. 5 98SN0155/WP/JAN280 pUBLIC FACILITIES The need for fire, school, library, park and transportation facilities is identified in the Public ~, the Thoroughfare Plan and the FY1997-2001 Capital Improvement Program. Since this proposal will not increase the number of dwelling units permitted on the property, there will be no additional impact on public facilities. The Public Facilities Plan indicates that Emergency Services calls are expected to increase forty-five (45) percent by the year 2015. Eight (8) new fire/rescue stations are recommended for construction by the year 2015 in the Public Facilities Plan. This property is currently served by the Buford Road Fire/Rescue Station, Company Number 9 and Forest View Rescu~ Squad. When the property is developed, the number of hydrants and quantity of water needed for fire prOtection will be evaluated during the plans review process. If 104 dwelling units are constructed, two (2) means of ingress/egress should be provided to accommodate emergency access should the main entrance become blocked. Transportation: Existing zoning would permit development of 104 townhouse units on the property. Based on townhouse trip rates, townhouse development Could generate approximately 670 average daily trips. In addition to the townhouse use, this request would permit development of convalescent homes, nursing homes, rest homes, day care centers, pharmacies and medical clinics on the property. Based on nursing home trip rates, development of the entire property could generate approximately 260 average daily trips. These vehicles will be distributed via Twinridge Lane and North Providence Road to Midlothian Turnpike (Route 60) and Buford Road which had 1995 traffic counts of 53,327 and 8,467 vehicles per day, respectively. Development must adhere to the Development Standards Manual in the Zoning Ordinance relative to access and internal circulation (Division 5). To address citizen concerns, the applicant has agreed that there will be no access to Winterslow Road (Proffered Condition 5). At time of site plan review, specific recommendation would be provided regarding access and internal circulation. 98SN0155/WP/JAN280 ~omprehensive Plan: Lies within the boundaries of the Northern Area Land Use and Transportation Plan which suggests the property is appropriate for residential use of 4.01 to 7.0 units per acre. The request property is also located within the boundaries of the proposed F_,astern Midlothian Area Land Use Plan. A draft of this Plan suggests the property is appropriate for residential use of 7.01 to 14 dwelling units per acre. Area Development Trends: Property to the north is zoned for residential or office use and is currently vacant. Due to the floodplain, it is unlikely that the office property will be developed. Single family residential zoning exists on a portion of the adjacent property to the east, south and west. Property to the south is occupied by a retirement home. The residentially zoned property to the east is occupied by single family residences or is vacant. The remaining property to the east is zoned and developed for office use. Property to the west has been developed as Bon Air Hills and Bon Air Vista Subdivisions. On March 26,. 1980, the Board of Supervisors, upon a favorable recommendation from the Planning Commission, approved rezoning to Residential Townhouse (R-TH) on the request property (Case 80S021). Case 80S021 was approved subject to a condition requiring a buffer along the western property boundary and proffered conditions addressing drainage issues. Proffered Condition 4 addresses the circumstances under which medical clinics and medical offices would be permitted. Specifically' medical clinics or offices would not be permitted until a certificate of occupancy has been issued for nursing home, rest home or convalescent home use. Non-Residential The request property lies within a Post Development Area. Redevelopment of the site or new construction must conform to the requirements of the Development Standards Manual which address access, parking, landscaping, architectural treatment, setbacks, signs, buffers, utilities and screening of dumpsters and loading areas. · 7 98SN0155/WP/JAN280 Any townhouse use must conform to the Development Standards Manual requirements for R-TH Districts. The applicant has proffered to limit residential townhouse development to a maximum of 104 units. (Proffered Condition 3) Architectural Treatment: Non-Residential Within Post Development Areas, no building exterior which would be visible to public rights of way can be constructed of unadorned concrete, block or corrugated and/or sheet metal. Mechanical equipment, whether ground-level or rooftop, must be shielded and screened from public rights of way. Redevelopment of the site or new construction for non-residential use must adhere to Post Development requirements. In addition, Proffered Condition 10 and Exhibit A, as attached, address as architectural style of non-residential uses. Acceptance of this proffer would require the architecture of any nursing home, rest home or convalescent home use to be as generally shown on the architectural elevations on Exhibit A and that any medical facility (office or clinic) be compatible in material, style and color with the elevations of the convalescent homes, nursing homes and rest homes. Proffered Condition 10 also allows the Planning Commission to approve modifications to architectural style at the time of Site Plan review provided the modifications comply with the spirit and intent of Exhibit A. The Zoning Ordinance requires that architectural plans for townhouses be submitted to the Planning Department for review and approval in conjunction with tentative subdivision plan submission. The Ordinance also requires that the front yard setback of each townhouse unit be varied from the adjacent unit. Buffers & Screening: The Zoning Ordinance requires that solid waste storage areas (i.e., dumpsters, garbage cans, trash compactors, etc.) be screened from view of adjacent property and public rights of way by a solid fence, wall, dense evergreen plantings or architectural feature, (be separated from any residentially zoned property or any property being used for residential purposes by the principal building, and that'such area within 1,000 feet of any residentially zoned property or property used for residential purposes not be serviced between the hours of 9:00 p.m. and 6:00 a.m. In addition, sites must be designed and buildings oriented so that loading areas are screened from any property where loading areas are prohibited and from public rights of way. 98SN0155/WP/JAN280 Adjacent property to the north, east and west is zoned Residential (R-15) and is occupied by single family residences or is vacant. The Zoning Ordinance requires a minimum seventy-five (75) foot buffer along the north, east and west property boundaries of the request site where adjacent to residentially zoned property. At the time of site plan review, the Planning Commission may modify this buffer under certain circumstances. In addition, at such time that adjacent residential property is zoned or utilized for a non-residential use, the buffer can be further reduced or eliminated. The applicant has agreed not to seek reduction of the buffer adjacent to the western property boundary to less than thirty (30) feet. (Proffered Condition 6) CONCLUSIONS The proposed zoning and land uses conform with the Northern Area 1 _~nd Use and Transportation Plan which suggests the property is appropriate for residential use of 4.01 to 7.0 units per acre and to the proposed Eastern Midlothian Area I_and Use Plan which suggests the property is appropriate for residential use of 7.01 to 14 units per acre. In addition, the proposed zoning and land uses are compatible with, and representative of, existing and anticipated area development. The requirements of the Development Standards Manual and proffered conditions will further insure land use compatibility with anticipated .area development. Given these considerations, approval of this request is recommended. CASE HISTORY Planning Commission Meeting (12/16/97): On their own motion, the Commission deferred this case to January 20, 1998. Staff (12/17/97): ' The applicant was advised in writing that any significant new or revised information should be submitted no later than December 29, 1997, for consideration at the Commission's January 20, 1998, public hearing. Applicant (12/19/97): The applicant submitted revised Proffered Condition 4, as discussed herein. 9 98SN0155/WP/JAN280 Applicant (1120/98): Modifications of Proffered Condition 4 and Proffered Condition 10 were submitted as discussed herein. Planning Commission Meeting (1/20/98): The applicant accepted the recommendation. There was no opposition present. On motion of Mr. Shewmake, seconded by Mr. Marsh, the Commission recommended approval of this request and acceptance of the proffered conditions on pages 2 and 3. AYES: Unanimous. The Board of Supervisors, on Wednesday, January 28, 1998, beginning at 7:00 p.m., will take under consideration this request. 10 98SN0155/WP/JAN280 C 2 Z¢ ¢ ;K HILL N BON AIR HILLS ZC C lllUll| 98SN0155 In Midlothian Magisterial District, BALANCED CARE CORPOP~ATION requested rezoning and amendment of zoning district map from Residential Townhouse (R-TH) to Community ~/28/98 98-54 Business (C-3) with Conditional Use to permit townhouses. The density of such amendment will be controlled by zoning conditions or Ordinance standards. The Comprehensive Plan suggests the property is appropriate for residential use of 4.01 to 7.0 units per acre. This request lies on 13.0 acres lying at the northern terminus of Twinridge Lane. GPIN 758- 707-5623 and 5783 (Sheet 8). Mr. Jacobson presented a summary of Case 98SN0155 and stated that staff and the Planning Commission recommend approval and acceptance of the proffered conditions. He noted that the request conforms to the Northern Area Land Use and Transportation Plan. Ms. Ashley Harwell, representing the applicant, stated the recommendation is acceptable. There was no opposition present. On motion of Mr. Barber, seconded by Mrs. Humphrey, the Board approved Case 98SN0151 and accepted the following proffered conditions: 1. Public water and wastewater systems shall be used. Except for the timbering approved by the Virginia State Department of Forestry for the purpose of removing dead or diseased trees, there shall be no timbering on the Property until a land disturbance permit has been obtained from the Environmental Engineering Department and the approved devices have been installed. The total number of residential units on the Property shall not exceed 104 units. NOTE: The present zoning is R-TH which allows up to 104 townhouse units. 4. The uses permitted on the Property shall be either: A. Any of the following: i. Convalescent homes, nursing homes and rest homes. ii. Nursery schools and child or adult care centers. iii . iv. Medical clinics, provided that a substantial or significant portion of its practice is not performing abortions and provided that such use shall not be permitted until a certificate of occupancy has been issued for A.i. above. Medical offices, provided that a substantial or significant portion of its practice is not performing abortions and provided that such use shall not be permitted until a certificate of occupancy has been issued for A.i. above. 1/~8/98 98-55 10. Ayes: Nays: or B. Townhouses. There shall be no access to Winterslow Road. Should a reduction be requested to the required seventy-five (75) foot buffer adjacent to residential zoning to the west no more than a 45' reduction in the buffer shall be requested. Unless required by the Utilities or Fire Department, the public water and wastewater systems shall not be extended from Winterslow Road. Site plans shall be submitted to the Commission for review and approval. Planning Drainage improvements shall be designed and constructed to mitigate potential for erosion and downstream flooding. The exact design and treatment of the improvements shall be reviewed and approved at the time of site plan review. The architecture of the use listed in 4.A.i. above shall be compatible in material, style and color as generally shown on the architectural elevations attached as Exhibit A. At the time of Site Plan review, the Planning Commission may approve modifications requested by the developer if such modifications are deemed to comply with the spirit and intent of the proposed elevations. Any medical clinic or office built on the Property shall be compatible in material, style, and color with the approved elevations for the convalescent homes, nursing homes, and rest homes. Humphrey, Warren, Barber, Daniel, and McHale. None. ~/~8/98 98-56